参数资料
型号: CS5376A-IQZR
厂商: Cirrus Logic Inc
文件页数: 16/49页
文件大小: 0K
描述: IC FILTER DGTL MULTI-CH 64-TQFP
标准包装: 1,000
滤波器类型: 数字
滤波器数: 4
滤波器阶数: 2nd
电源电压: 3 V ~ 5 V
安装类型: 表面贴装
封装/外壳: 64-LQFP
供应商设备封装: 64-TQFP(10x10)
包装: 带卷 (TR)
配用: 598-1778-ND - EVALUATION BOARD FOR CS5376
2008 Fairchild Semiconductor Corporation
www.fairchildsemi.com
FUSB2805 Rev. 1.0.3
23
F
USB2
8
0
5
USB2
.0
High
-S
pee
d
OTG
Tra
nsc
e
iv
e
rw
ith
UL
P
I
Inter
fac
e
VBUS Voltage State Encoding
As mentioned in Table 9, changes in the VBUS state
encoding initiate an RXCMD to the link. For the link to
receive VBUS state updates, the link must first enable the
corresponding interrupts in the USB_INTR_EN_R and
USB_INTR_EN_F registers. Link uses the indicator
signals to take action based on typical configurations
(host, peripheral, OTG device). Table 12 shows the
VBUS indicators in RXCMD based on the configuration.
Table 12. VBUS Indicator Signals in RXCMD
Configuration A_VBUS_
VLD
SESS_
VLD
SESS_
END
Standard Host
Yes
No
Standard
Peripheral
No
Yes
No
OTG A-Device
Yes
No
OTG B-Device
No
Yes
For the standard USB host controller application, the
following applies:
The system must be able to provide 500 mA
for 4.75
V ≤ VBUS ≤ 5.25 V.
An external circuit is to be used to detect over-
current conditions. If the external over-current detector
provides a digital fault signal, the signal must be
connected to the FAULT input pin and the link must do
the following:
1.
Set the IND_COMPL bit in the INTF_CTRL
register to 0b or 1b, depending on the polarity
of the external fault signal.
2.
Set
the
USE_EXT_VBUS_IND
bit
in
the
OTG_CTRL register to 1b.
3.
If it is not necessary to qualify the fault
indicator
with
the
internal
A_VBUS_VLD
comparator, set the IND_PASSTHRU bit in the
INTF_CTRL register to 1b.
For
the
standard
USB
peripheral
controller
applications, the standard peripherals detect when
VBUS is at a sufficient level for operation. SESS_VLD
must be enabled to detect the start and end of a
USB
peripheral
operation.
Detection
of
the
A_VBUS_VLD and SESS_END thresholds is not
needed for standard peripherals.
For a device configured as an OTG B-device, SESS_VLD
must be used to detect when VBUS is at a sufficient level
for operation. SESS_END must be used to detect when
VBUS has dropped to a LOW level, allowing the B-device
to safely initiate VBUS pulsing SRP.
A device configured as an OTG A-device must provide
a minimum of 8 mA onto VBUS. This 8 mA (minimum) is
provided external to the FUSB2805. If the external
charge pump source provides more than 100 mA, the
over-current circuit must be used and the host controller
application criteria apply. The OTG A-device also uses
SESS_VLD to detect when an OTG B-device is initiating
VBUS pulsing SRP. The control of this external charge
pump is accomplished via the PSW pin.
RxEvent Encoding
As mentioned in Table 9, this encoding provides
information to the link related to the packets received on
the USB bus. The primary encodings are RxActive,
RxError, and HostDisconnect.
RxActive
When the FUSB2805 detects a SYNC pattern on the
USB bus, it signals an RxActive event to the link. This
RxActive event can be communicated in two methods:
FUSB2805 simultaneously asserts DIR and NXT; or
FUSB2805 sends an RXCMD to the link with the
RxActive field in the RxEvent bits set to 1b.
The link must be capable of detecting both methods
and the RxActive frames the receive packet from the
first byte to the last byte. It also must assume that
RxActive is set to 0b when indicated in an RXCMD or
when DIR is de-asserted, whichever occurs first.
The RxActive is also used by the link to time the high-
speed packets and ensure that the bus turn-around
times are met.
RxError
When the FUSB2805 detects an error while receiving a
USB packet, it de-asserts NXT and sends an RXCMD
with the RxError field set to 1b. The received packet is
no longer valid and must be dropped by the link.
HostDisconnect
This encoding is only valid when the FUSB2805 is
configured
as
a
host
(DP_PULLDOWN=
DM_PULLDOWN=1b)
and
indicates
to
the
host
controller when a peripheral is connected (0b) or
disconnected (1b). The host controller must enable
HostDisconnect by setting the HOST_DISCON_R and
HOST_DISC_F bits in the USB_INTR_EN_R and
USB_INTR_EN_F registers, respectively. Changes in
HostDisconnect cause the FUSB2805 to send an
RXCMD to the link with the updated value.
In peripheral mode, HostDisconnect must be ignored
and must not mask events on RxActive or RxError.
Refer to ULPI specifications, section 3.8.1 for details on
RXCMD and TXCMD operations and functionality.
相关PDF资料
PDF描述
VE-20K-IY-F2 CONVERTER MOD DC/DC 40V 50W
MC9S08JS8LCWJ MCU 8BIT 8K FLASH 20-SOIC
VE-20K-IY-F1 CONVERTER MOD DC/DC 40V 50W
LTC1064-1ACN IC FILTR 8TH ORDR LOWPASS 14-DIP
LTC1264-7CSW#TR IC FILTER LP 8ORD 250KHZ 16SOIC
相关代理商/技术参数
参数描述
CS5376-BQ 制造商:Rochester Electronics LLC 功能描述:- Bulk
CS5378 制造商:CIRRUS 制造商全称:Cirrus Logic 功能描述:Low-power Single-channel Decimation Filter
CS5378_08 制造商:CIRRUS 制造商全称:Cirrus Logic 功能描述:Low-power Single-channel Decimation Filter
CS5378-IS 功能描述:特殊用途放大器 IC LP Single-Ch Decimation Filter RoHS:否 制造商:Texas Instruments 通道数量:Single 共模抑制比(最小值): 输入补偿电压: 工作电源电压:3 V to 5.5 V 电源电流:5 mA 最大功率耗散: 最大工作温度:+ 70 C 最小工作温度:- 40 C 安装风格:SMD/SMT 封装 / 箱体:QFN-20 封装:Reel
CS5378-ISZ 功能描述:特殊用途放大器 IC LP Single-Ch Decimation Filter RoHS:否 制造商:Texas Instruments 通道数量:Single 共模抑制比(最小值): 输入补偿电压: 工作电源电压:3 V to 5.5 V 电源电流:5 mA 最大功率耗散: 最大工作温度:+ 70 C 最小工作温度:- 40 C 安装风格:SMD/SMT 封装 / 箱体:QFN-20 封装:Reel