Bit 0: Enable Oscillator (EOSC). This bit controls the
crystal oscillator of the RTC. When set to logic 1, the
oscillator starts. When written to logic 0, the oscillator
stops and the device is in a low-power data-retention
mode. This bit must be 1 for normal operation. A
Forced Conversion or Start Mission command automati-
cally starts the RTC by changing the EOSC bit to
logic 1.
Mission Control
The DS1923 is set up for its operation by writing appro-
priate data to its special function registers, which are
located in the two register pages. The settings in the
Mission Control register determine whether temperature
and/or humidity is logged, which format (8 or 16 bits)
applies, and whether old data can be overwritten by
new data once the data-log memory is full. An addition-
al control bit can be set to tell the DS1923 to wait with
logging data until a temperature alarm is encountered.
Bit 5: Start Mission Upon Temperature Alarm
(SUTA). This bit specifies whether a mission begins
immediately (includes delayed start) or if a temperature
alarm is required to start the mission. If this bit is 1, the
device performs an 8-bit temperature conversion at the
selected sample rate and begins with data logging only
if an alarming temperature (high alarm or low alarm)
was found. The first logged temperature is when the
alarm occurred. However, the Mission Samples
Counter does not increment. The start upon tempera-
ture alarm function is only available if temperature log-
ging is enabled (ETL = 1).
Bit 4: Rollover Control (RO). This bit controls whether,
during a mission, the data-log memory is overwritten
with new data or whether data logging is stopped once
the data-log memory is full. Setting this bit to 1 enables
the rollover and data logging continues at the begin-
ning, overwriting previously collected data. If this bit is
0, the logging and conversions stop once the data-log
memory is full. However, the RTC continues to run and
the MIP bit remains set until the Stop Mission command
is performed.
Bit 3: Humidity Logging Format Selection (HLFS).
This bit specifies the format used to store humidity
readings in the data-log memory. If this bit is 0, the
data is stored in 8-bit format. If this bit is 1, the 16-bit
format is used (higher resolution). With 16-bit format,
the most significant byte is stored at the lower address.
Bit 2: Temperature Logging Format Selection
(TLFS). This bit specifies the format used to store tem-
perature readings in the data-log memory. If this bit is
0, the data is stored in 8-bit format. If this bit is 1, the
16-bit format is used (higher resolution). With 16-bit for-
mat, the most significant byte is stored at the lower
address.
Bit 1: Enable Humidity Logging (EHL). To set up the
DS1923 for a humidity-logging mission, this bit must be
set to logic 1. If temperature and humidity logging are
enabled, the recorded humidity values begin at
address 2000h (TLFS = HLFS) or 1A00h (TLFS = 0;
HLFS = 1) or 2400h (TLFS = 1; HLFS = 0). If only
humidity logging is enabled, the recorded values are
stored starting at address 1000h. Since humidity data
has little scientific value without knowing the tempera-
ture, typically both humidity and temperature logging
are enabled (i.e., ETL and EHL are set to 1).
Bit 0: Enable Temperature Logging (ETL). To set up
the device for a temperature-logging mission, this bit
must be set to logic 1. To successfully start a mission,
ETL or EHL must be 1. If temperature logging is
enabled, the recorded temperature values are always
stored starting at address 1000h.
Mission Control Register Bitmap
ADDRESS
0213h
BIT 7
1
BIT 6
1
BIT 5
SUTA
BIT 4
RO
BIT 3
HLFS
BIT 2
TLFS
BIT 1
EHL
BIT 0
ETL
Note: During a mission, there is only read access to this register. Bits 6 and 7 have no function. They always read 1 and cannot be written to 0.
Maxim Integrated
21
相关PDF资料
PDF描述
DS1961S-F3# IBUTTON EEPROM 1KBit F3
DS1963S-F5+ IBUTTON MONETARY SHA-1
DS1971-F3+ IBUTTON EEPROM 256KBIT F3
DS1972-F3+ IBUTTON EEPROM 1KBit F3
DS1973-F3+ IBUTTON EEPROM 4KBit F3
相关代理商/技术参数
参数描述
DS1923-F5# 功能描述:iButton Hygrochron Temp/Hum Logger w/8KB DataLog RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1923-F5#W 功能描述:iButton Hygrochron Temp/Hum Logger w/8KB DataLog RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1923-F5+ 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS19310 制造商:SANYO 制造商全称:Sanyo Semicon Device 功能描述:Color TV Owners Manual Manuel dinstructions du teleouleur Color TV Manual Del Propietario
DS193-K 制造商:Miyama Electric 功能描述: