DS1923
iButton Hygrochron Temperature/Humidity
Logger with 8KB Data-Log Memory
1-Wire Communication Examples (continued)
Forced Conversion
RST PD Select FC
FFh
FF Loop
To read the result and to verify success, read the addresses 020Ch to 020Fh (results) and the Device Samples
Counter at address 0223h to 0225h. If the count has incremented, the command was executed successfully.
Start Mission with Password
RST PD Select SM
<PW/Dummy>
FFh
FF Loop
To verify success, read the General Status register at address 0215h. If MIP is 1 and MEMCLR is 0, the command
was executed successfully.
Stop Mission with Password
RST PD Select STP
<PW/Dummy>
FFh
FF Loop
To verify success, read the General Status register at address 0215h. If MIP is 0, the command was executed
successfully.
Mission Example: Prepare
and Start a New Mission
Assumption: The previous mission has been ended by
using the Stop Mission command. Passwords are not
enabled. The device is a DS1923.
Starting a mission requires three steps:
Step 1: Clear the data of the previous mission.
Step 2: Write the setup data to register page 1.
Step 3: Start the new mission.
Step 1: Clear the data of the previous mission.
With only a single device connected to the bus master,
the communication of step 1 looks like this:
MASTER MODE
Tx
Rx
Tx
Tx
Tx
Tx
Tx
Rx
Maxim Integrated
DATA (LSB FIRST)
(Reset)
(Presence)
CCh
96h
<8 FFh bytes>
FFh
(Reset)
(Presence)
COMMENTS
Reset pulse
Presence pulse
Issue “Skip ROM ” command
Issue “Clear Memory” command
Send dummy password
Send dummy byte
Reset pulse
Presence pulse
47
相关PDF资料
PDF描述
DS1961S-F3# IBUTTON EEPROM 1KBit F3
DS1963S-F5+ IBUTTON MONETARY SHA-1
DS1971-F3+ IBUTTON EEPROM 256KBIT F3
DS1972-F3+ IBUTTON EEPROM 1KBit F3
DS1973-F3+ IBUTTON EEPROM 4KBit F3
相关代理商/技术参数
参数描述
DS1923-F5# 功能描述:iButton Hygrochron Temp/Hum Logger w/8KB DataLog RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1923-F5#W 功能描述:iButton Hygrochron Temp/Hum Logger w/8KB DataLog RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1923-F5+ 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS19310 制造商:SANYO 制造商全称:Sanyo Semicon Device 功能描述:Color TV Owners Manual Manuel dinstructions du teleouleur Color TV Manual Del Propietario
DS193-K 制造商:Miyama Electric 功能描述: