ADC 的数量: 1
位数: 24
采样率(每秒): 6.4k
数据接口: 串行
输入范围: ±1.28 V
在以下条件下的电源(标准): 67.5mW @ 6.4kSPS
工作温度: -40°C ~ 85°C
已用 IC / 零件: AD7731
已供物品: 板,CD
相关产品: AD7731BNZ-ND - IC ADC 24BIT SIGMA-DELTA 24DIP
AD7731BRUZ-REEL7-ND - IC ADC 24BIT SIGMA-DELTA 24TSSOP
AD7731BRUZ-REEL-ND - IC ADC 24BIT SIGMA-DELTA 24TSSOP
AD7731BRUZ-ND - IC ADC 24BIT SIGMA-DELTA 24TSSOP
AD7731BRZ-REEL7-ND - IC ADC 24BIT SIGMA-DELTA 24-SOIC
AD7731BRZ-REEL-ND - IC ADC 24BIT SIGMA-DELTA 24-SOIC
AD7731BRZ-ND - IC ADC 24BIT SIGMA-DELTA 24-SOIC
AD7731BRU-REEL7-ND - IC ADC 24BIT SIGMA-DELTA 24TSSOP
AD7731BRU-ND - IC ADC 24BIT SIGMA-DELTA 24TSSOP
AD7731BR-REEL7-ND - IC ADC 24BIT SIGMA-DELTA 24-SOIC
更多...
AD7731
–4–
REV. 0
NOTES
1 Temperature Range: –40
°C to +85°C.
2 Sample tested during initial release.
3 No missing codes performance with CHP = 0 and SKIP = 1 is 22 bits.
4 The offset (or zero) numbers with CHP = 0 can be up to 1 mV precalibration. Internal zero-scale calibration reduces this to 2
V typical. Offset numbers with CHP = 1 are typically
3
V precalibration. Internal zero-scale calibration reduces this by about 1 V. System zero-scale calibration reduces offset numbers with CHP = 0 and CHP = 1 to the order of the
noise. Gain errors can be up to 3000 ppm precalibration with CHP = 0 and CHP = 1. Performing internal full-scale calibrations on all input ranges except the 20 mV and 40 mV input
range reduces the gain error to less than 100 ppm. When operating on the 20 mV or 40 mV range, an internal full-scale calibration should be performed on the 80 mV input range with
a resulting gain error of less than 250 ppm. System full-scale calibration reduces the gain error on all input ranges to the order of the noise. Positive and Negative Full-Scale Errors can
be calculated from the offset and gain errors.
5 These numbers are generated during life testing of the part.
6 Positive Full-Scale Error includes Zero-Scale Errors (Unipolar Offset Error or Bipolar Zero Error) and applies to both unipolar and bipolar input ranges. See Terminology.
7 Recalibration at any temperature will remove these errors.
8 Full-scale drift includes Zero-Scale Drift (Unipolar Offset Drift or Bipolar Zero Drift) and applies to both unipolar and bipolar input ranges.
9 Gain Error is a measure of the difference between the measured and the ideal span between any two points in the transfer function. The two points use to calculate the gain error are
positive full-scale and negative full-scale. See Terminology.
10 Gain Error Drift is a span drift and is effectively the drift of the part if zero-scale calibrations only were performed.
11 Power Supply Rejection and Common-Mode Rejection are given here for the upper and lower input voltage ranges. The rejection can be approximated to varying linearly (in dBs)
between these values for the other input ranges.
12 The analog input voltage range on the AIN(+) inputs is given here with respect to the voltage on the respective AIN(–) input.
13 The common-mode voltage range on the input pairs applies provided the absolute input voltage specification is obeyed.
14 The common-mode voltage range on the reference input pair (REF IN(+) and REF IN(–)) applies provided the absolute input voltage specification is obeyed.
15 These logic output levels apply to the MCLK OUT output only when it is loaded with a single CMOS load.
16 V
DD refers to DVDD for all logic outputs expect D0 and D1 where it refers to AVDD. In other words, the output logic high for these two outputs is determined by AVDD.
17 See Burnout Current section.
18 After calibration, if the input voltage exceeds positive full scale, the converter will output all 1s. If the input is less than negative full scale, then the device outputs all 0s.
19 These calibration and span limits apply provided the absolute input voltage specification is obeyed. The offset calibration limit applies to both the unipolar zero point and the bipolar
zero point.
Specifications subject to change without notice.
Limit at TMIN, TMAX
Parameter
(B Version)
Units
Conditions/Comments
Master Clock Range
1
MHz min
For Specified Performance
5
MHz max
t1
50
ns min
SYNC Pulse Width
t2
50
ns min
RESET Pulse Width
Read Operation
t3
0
ns min
RDY to CS Setup Time
t4
0
ns min
CS Falling Edge to SCLK Active Edge Setup Time3
t5
4
0
ns min
SCLK Active Edge to Data Valid Delay
60
ns max
DVDD = +4.75 V to +5.25 V
80
ns max
DVDD = +2.7 V to +3.3 V
t5A
0
ns min
CS Falling Edge to Data Valid Delay3
60
ns max
DVDD = +4.75 V to +5.25 V
80
ns max
DVDD = +2.7 V to +3.3 V
t6
100
ns min
SCLK High Pulse Width
t7
100
ns min
SCLK Low Pulse Width
t8
0
ns min
CS Rising Edge to SCLK Inactive Edge Hold Time3
10
ns min
Bus Relinquish Time after SCLK Inactive Edge
80
ns max
t10
100
ns max
SCLK Active Edge to
Write Operation
t11
0
ns min
CS Falling Edge to SCLK Active Edge Setup Time3
t12
30
ns min
Data Valid to SCLK Edge Setup Time
t13
25
ns min
Data Valid to SCLK Edge Hold Time
t14
100
ns min
SCLK High Pulse Width
t15
100
ns min
SCLK Low Pulse Width
t16
0
ns min
CS Rising Edge to SCLK Edge Hold Time
NOTES
1 Sample tested during initial release to ensure compliance. All input signals are specified with tr = tf = 5 ns (10% to 90% of DV
DD) and timed from a voltage level of 1.6 V.
3 SCLK active edge is falling edge of SCLK with POL = 1; SCLK active edge is rising edge of SCLK with POL = 0.
4 These numbers are measured with the load circuit of Figure 1 and defined as the time required for the output to cross the V
OL or VOH limits.
5 This specification only comes into play if
CS goes low while SCLK is low (POL = 1) or if CS goes low while SCLK is high (POL = 0). It is required primarily for interfacing to
DSP machines.
6 These numbers are derived from the measured time taken by the data output to change 0.5 V when loaded with the circuit of Figure 1. The measured number is then extrapo-
lated back to remove effects of charging or discharging the 50 pF capacitor. This means that the times quoted in the timing characteristics are the true bus relinquish times of the
part and as such are independent of external bus loading capacitances.
7
RDY returns high after the first read from the device after an output update. The same data can be read again, if required, while RDY is high, although care should be taken that
subsequent reads do not occur close to the next output update.
(AVDD = +4.75 V to +5.25 V; DVDD = +2.7 V to +5.25 V; AGND = DGND = 0 V;
fCLK IN = 4.9152 MHz; Input Logic 0 = 0 V, Logic 1 = DVDD unless otherwise noted)
REV. A
相关PDF资料
PDF描述
VI-B7J-EY CONVERTER MOD DC/DC 36V 50W
RMM06DTKN-S288 CONN EDGECARD 12POS .156 EXTEND
VI-B7H-EY CONVERTER MOD DC/DC 52V 50W
SDS130R-302N INDUCTOR PWR SHIELDED 3.0UH SMD
VI-B74-EY CONVERTER MOD DC/DC 48V 50W
相关代理商/技术参数
参数描述
EVAL-AD7732EB 制造商:Analog Devices 功能描述:2-CHANNEL, ??10 V INPUT RANGE, HIGH THROUGHPUT, 24-BIT ADC
EVAL-AD7732EBZ 功能描述:BOARD EVAL FOR AD7732 RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件
EVAL-AD7734EBZ 功能描述:BOARD EVALUATION FOR AD7734 RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件
EVAL-AD7738EB 制造商:Analog Devices 功能描述:Evaluation Board For AD7738 ADC 制造商:Analog Devices 功能描述:EVALUATION BOARD I.C. - Bulk
EVAL-AD7738EBZ 功能描述:BOARD EVAL FOR AD7738 RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件