HM62V8512B Series
6
DC Characteristics (Ta = –20 to +70
°C, V
CC = 2.7 V to 3.6 V, VSS = 0 V)
Parameter
Symbol
Min
Typ*
1
Max
Unit Test conditions
Input leakage current
|I
LI|
——1
A
Vin = V
SS to V CC
Output leakage current
|I
LO|
——1
A
CS = V
IH or OE = VIH or
WE = V
IL, VI/O = VSS to V CC
Operating power
supply current: DC
I
CC
——10
mA
CS = V
IL,
others = V
IH/VIL, II/O = 0 mA
Operating
power supply current
I
CC1
—
40
mA
Min cycle, duty = 100%
CS = V
IL, others = VIH/VIL
I
I/O = 0 mA
Operating power
supply current
I
CC2
—
5
10
mA
Cycle time = 1
s,
duty = 100%
I
I/O = 0 mA, CS ≤ 0.2 V
V
IH ≥ V CC – 0.2 V,
V
IL ≤ 0.2 V
Standby power supply
current: DC
I
SB
—
0.1
0.3
mA
CS = V
IH
Standby power supply
current (1): DC
I
SB1
—1*
2
40*
2
A
Vin
≥ 0 V,
CS
≥ V
CC – 0.2 V
—1*
3
20*
3
A
—1*
4
5*
4
A
Output low voltage
V
OL
—
0.4
V
I
OL = 2.1 mA
—
0.2
V
I
OL = 100 A
Output high voltage
V
OH
V
CC – 0.2 —
—
V
I
OH = –100 A
2.4
—
V
I
OH = –1.0 mA
Notes: 1. Typical values are at V
CC = 3.0 V, Ta = +25°C and specified loading, and not guaranteed.
2. This characteristics is guaranteed only for L version.
3. This characteristics is guaranteed only for L-SL version.
4. This characteristics is guaranteed only for L-UL version.
Capacitance (Ta = +25
°C, f = 1 MHz)
Parameter
Symbol
Typ
Max
Unit
Test conditions
Input capacitance*
1
Cin
—
8
pF
Vin = 0 V
Input/output capacitance*
1
C
I/O
—10
pF
V
I/O = 0 V
Note:
1. This parameter is sampled and not 100% tested.