参数资料
型号: ISL12082IUZ-T
厂商: Intersil
文件页数: 8/26页
文件大小: 0K
描述: IC RTC I2C LO-POWER 10-MSOP
标准包装: 2,500
类型: 时钟/日历
特点: 警报器,闰年,监视计时器
时间格式: HH:MM:SS:hh(12/24 小时)
数据格式: YY-MM-DD-dd
接口: I²C,2 线串口
电源电压: 2.7 V ~ 5.5 V
电压 - 电源,电池: 1.8 V ~ 5.5 V
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 10-TFSOP,10-MSOP(0.118",3.00mm 宽)
供应商设备封装: 10-MSOP
包装: 带卷 (TR)
16
FN6731.3
November 24, 2008
Sub-Timer Initial Register (TSDAT, address 14h) is set to “0”,
the number of counts changes to the default value. The
maximum register value for the TSDAT register is 127 which
means the maximum limit for the internal Sub-Timer Counter
Register is also 127. See Table 10 for Timer/Watchdog clock
frequency selection and the default counts for the Sub-Timer
Counter Register.
The Timer Counter and Sub-Timer Counter Registers
advance the counter value based on the frequency or time
setting by the TCLK<1:0> bits.
The following are examples of Timer clock frequency
selection bits on Timer Counter and Sub-Timer Counter
Registers.
Example 1 - TCLK1 is set to “1”, TCLK0 is set to “0”, and
Sub-Timer Initial Register is set to “0”. The internal
Sub-Timer Counter will increment every 1s. When the
internal Sub-Timer Counter reaches to 60, the default value,
the Timer Counter will increment by one which means the
Timer Counter will increment every one minute.
Example 2- TCLK1 is set to “1”, TCLK0 is set to “0”, and
Sub-Timer Initial Register is set to “10d”. The internal
Sub-Timer Counter will increment every 1s. When the
internal Sub-Timer Counter reaches to 10, the Timer
Counter will increment by one which means the Timer
Counter will increment every ten seconds.
Example 3- TCLK1 is set to “0”, TCLK0 is set to “1”, and
Sub-Timer Initial Register is set to “0”. The internal
Sub-Timer Counter will increment every 1ms (100Hz). When
the internal Sub-Timer Counter reaches to 100, the default
value2, the Timer Counter will increment by one which
means the Timer Counter will increment every one second.
TIMER FUNCTION SELECTION BITS (TMOD <1:0>)
The Timer interrupt has four different functions:
1. Count Down Timer
2. Secondary Alarm Timer
3. Watchdog Timer
4. Power Fail Count-up Timer
Please see Table 11 for Timer counting functions selection.
TIMER ENABLE BIT (TMRE)
This bit enables/disables the timer function. When the TMRE
bit is set to “1”, the timer is enabled. To display timer interrupt
on the IRQ2 pin, the IRQ2E has to be set to “1”. When the
TMRE bit is cleared to “0”, the timer function is disabled. The
TMRE bit is set to “0” on power-up.
TIMER PULSE/EVENT INTERRUPT BIT (TIM)
This bit enables/disables the interrupt mode of the timer
function. When the TIM bit is set to “1”, the timer will operate
in the interrupt mode. An active low pulse width of 210ms will
appear at the IRQ2 pin when the RTC is triggered by the
timer as defined by the timer registers (12h to 15h). When
the TIM bit is cleared to “0”, the timer will operate in standard
mode, where the IRQ2 pin will be held low until TMR status
bit is cleared to “0”. The TIM bit is set to “0” on power-up.
Timer Registers
Addresses [12h to 15h]
Timer Initial Register (TDAT) [Address 12h]
The Timer Initial Register is located in the memory map at
address 12h. This is a volatile register that stores the timer
limit for the timer counter register.
TABLE 10. TIMER CLOCK FREQUENCY SELECTION AND
DEFAULT VALUE FOR TSDAT REGISTER
TCLK1 TCLK0 FUNCTION
COMMENT
0
100Hz/4kHz 100Hz for TCNT, 4kHz for TSCNT
Default Value for TSDAT = 41
(41 TSCNT counts = 1ms)
(Not available for Watchdog Timer)
0
1
1sec/100Hz 1sec for TCNT, 100Hz for TSCNT
Default Value for TSDAT = 100
(100 TSCNT counts = 1s)
1
0
1min/1sec
1min for TCNT, 1sec for TSCNT
Default Value for TSDAT = 60
(60 TSCNT counts = 1min)
(RTC must be enabled)
1
1hr/1min
1hour for TCNT, 1min for TSCNT
Default Value for TSDAT = 60
(60 TSCNT counts = 1hr)
(RTC must be enabled)
TABLE 11. TIMER COUNTING FUNCTION SELECTION
TMOD1 TMOD0
FUNCTION
COMMENT
0
Count Down
Timer
Basic count down timer
(TCNT register decrement)
0
1
Secondary
Alarm Timer
Basic count down timer activated by
ALARM IRQ (ALM bit)
(TCNT register decrement)
1
0
Watchdog
Timer
Count up timer with periodic
interrupt
(TCNT register increment)
11
Power Fail
Count-up
Timer
Count up after device entered into
battery mode
(TCNT register increment)
TIM BIT
TIMER PULSE/EVENT INTERRUPT FUNCTION
0
Single Time Event Set By Timer
1
Repetitive/Recurring Time Event Set By Timer
TABLE 12. TIMER INITIAL REGISTER (TDAT)
ADDR
76543210
12h
TDAT7 TDAT6 TDAT5 TDAT4 TDAT3 TDAT2 TDAT1 TDAT0
Default
00000000
ISL12082
相关PDF资料
PDF描述
VI-BN2-MV CONVERTER MOD DC/DC 15V 150W
MS3102A36-8S CONN RCPT 47POS BOX MNT W/SCKT
MS27466T21F11P CONN RCPT 11POS WALL MT W/PINS
ISL23418TFUZ-T7A IC DGTL POT 1CH 100K 10MSOP
D38999/26WH21PA CONN PLUG 21POS STRAIGHT W/PINS
相关代理商/技术参数
参数描述
ISL1208EVAL 功能描述:电源管理IC开发工具 EVALRD FOR ISL1208 RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
ISL1208IB8 功能描述:IC RTC/CALENDAR I2C 8-SOIC RoHS:否 类别:集成电路 (IC) >> 时钟/计时 - 实时时钟 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- 类型:时钟/日历 特点:警报器,闰年,SRAM 存储容量:- 时间格式:HH:MM:SS(12/24 小时) 数据格式:YY-MM-DD-dd 接口:SPI 电源电压:2 V ~ 5.5 V 电压 - 电源,电池:- 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:8-WDFN 裸露焊盘 供应商设备封装:8-TDFN EP 包装:管件
ISL1208IB8-TK 功能描述:IC RTC/CALENDAR I2C 8-SOIC RoHS:否 类别:集成电路 (IC) >> 时钟/计时 - 实时时钟 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- 类型:时钟/日历 特点:警报器,闰年,SRAM 存储容量:- 时间格式:HH:MM:SS(12/24 小时) 数据格式:YY-MM-DD-dd 接口:SPI 电源电压:2 V ~ 5.5 V 电压 - 电源,电池:- 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:8-WDFN 裸露焊盘 供应商设备封装:8-TDFN EP 包装:管件
ISL1208IB8Z 功能描述:实时时钟 I2C REAL TIME CLOCK/ CALENDAR 8LD RoHS:否 制造商:Microchip Technology 功能:Clock, Calendar. Alarm RTC 总线接口:I2C 日期格式:DW:DM:M:Y 时间格式:HH:MM:SS RTC 存储容量:64 B 电源电压-最大:5.5 V 电源电压-最小:1.8 V 最大工作温度:+ 85 C 最小工作温度: 安装风格:Through Hole 封装 / 箱体:PDIP-8 封装:Tube
ISL1208IB8ZR5291 功能描述:实时时钟 I2CAL TIME CLK/CLNDR ALL BATRY MODE TESTS RoHS:否 制造商:Microchip Technology 功能:Clock, Calendar. Alarm RTC 总线接口:I2C 日期格式:DW:DM:M:Y 时间格式:HH:MM:SS RTC 存储容量:64 B 电源电压-最大:5.5 V 电源电压-最小:1.8 V 最大工作温度:+ 85 C 最小工作温度: 安装风格:Through Hole 封装 / 箱体:PDIP-8 封装:Tube