参数资料
型号: KSZ8863RLLI
厂商: Micrel Inc
文件页数: 42/106页
文件大小: 0K
描述: IC ETHERNET SWITCH 3PORT 48-LQFP
标准包装: 250
控制器类型: 以太网开关控制器
接口: MII
电源电压: 1.8V,2.5V,3.3V
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 48-LQFP
供应商设备封装: 48-LQFP(7x7)
包装: 托盘
配用: 576-3868-ND - BOARD EVALUATION FOR KSZ8863RLL
其它名称: 576-3752
Micrel, Inc.
KSZ8863MLL/FLL//RLL
January 27, 2014
4
Revision 1.5
Contents
Functional Diagram............................................................................................................................................................... 1
Applications........................................................................................................................................................................... 2
Pin Description and I/O Assignment ................................................................................................................................. 12
Pin Configuration ................................................................................................................................................................ 16
Functional Description ....................................................................................................................................................... 17
Functional Overview: Physical Layer Transceiver .......................................................................................................... 17
100BASE-TX Transmit ..................................................................................................................................................... 17
100BASE-TX Receive ...................................................................................................................................................... 17
PLL Clock Synthesizer...................................................................................................................................................... 17
Scrambler/De-scrambler (100BASE-TX Only) ................................................................................................................. 17
100BASE-FX Operation.................................................................................................................................................... 17
100BASE-FX Signal Detection ......................................................................................................................................... 18
100BASE-FX Far-End Fault ............................................................................................................................................. 18
10BASE-T Transmit.......................................................................................................................................................... 18
10BASE-T Receive ........................................................................................................................................................... 18
MDI/MDI-X Auto Crossover .............................................................................................................................................. 18
Straight Cable ............................................................................................................................................................ 19
Crossover Cable ........................................................................................................................................................ 20
Auto-Negotiation ............................................................................................................................................................... 21
LinkMD
Cable Diagnostics.............................................................................................................................................. 22
Access ....................................................................................................................................................................... 22
Usage......................................................................................................................................................................... 22
Functional Overview: Power Management....................................................................................................................... 22
Normal Operation Mode ................................................................................................................................................... 23
Energy Detect Mode ......................................................................................................................................................... 23
Soft Power Down Mode .................................................................................................................................................... 23
Power Saving Mode.......................................................................................................................................................... 23
Port based Power Down Mode ......................................................................................................................................... 23
Functional Overview: MAC and Switch ............................................................................................................................ 24
Address Lookup ................................................................................................................................................................ 24
Learning ............................................................................................................................................................................ 24
Migration ........................................................................................................................................................................... 24
Aging................................................................................................................................................................................. 24
Forwarding ........................................................................................................................................................................ 24
Switching Engine .............................................................................................................................................................. 27
MAC Operation ................................................................................................................................................................. 27
Inter Packet Gap (IPG) .............................................................................................................................................. 27
Back-Off Algorithm..................................................................................................................................................... 27
Late Collision ............................................................................................................................................................. 27
Illegal Frames ............................................................................................................................................................ 27
Full Duplex Flow Control............................................................................................................................................ 27
Half-Duplex Backpressure ......................................................................................................................................... 27
Broadcast Storm Protection....................................................................................................................................... 28
Port Individual MAC address and Source Port Filtering ............................................................................................ 28
MII Interface Operation ..................................................................................................................................................... 28
RMII Interface Operation .................................................................................................................................................. 29
MII Management (MIIM) Interface .................................................................................................................................... 32
Serial Management Interface (SMI).................................................................................................................................. 33
相关PDF资料
PDF描述
V72A3V3C264BG3 CONVERTER MOD DC/DC 3.3V 264W
KSZ8851SNL TR IC CTLR MAC/PHY NON-PCI 32-MLF
PIC16F676-E/SL IC MCU FLASH 1KX14 W/AD 14SOIC
LTC4278IDKD#PBF IC PD IEEE 802.3AT 25.5W 32-DFN
KSZ8873MML IC ETHERNET SWITCH 3PORT 64-LQFP
相关代理商/技术参数
参数描述
KSZ8864CNXCA 功能描述:Ethernet Controller 10/100 Base-T/TX PHY MII, RMII Interface 64-QFN (8x8) 制造商:microchip technology 系列:- 包装:托盘 零件状态:有效 协议:以太网 功能:控制器 接口:MII,RMII 标准:10/100 Base-T/TX PHY 电压 - 电源:1.8V,2.5V,3.3V 电流 - 电源:- 工作温度:0°C ~ 70°C 封装/外壳:64-VFQFN 裸露焊盘 供应商器件封装:64-QFN(8x8) 标准包装:348
KSZ8864RMN 功能描述:以太网 IC 4-Port 10/100 Ethernet Switch w/ 2x PHYs and 2x MAC Interface RoHS:否 制造商:Micrel 产品:Ethernet Switches 收发器数量:2 数据速率:10 Mb/s, 100 Mb/s 电源电压-最大:1.25 V, 3.45 V 电源电压-最小:1.15 V, 3.15 V 最大工作温度:+ 85 C 封装 / 箱体:QFN-64 封装:Tray
KSZ8864RMN-EVAL 功能描述:以太网开发工具 4-Port 10/100 Ethernet Switch w/ 2x PHYs and 2x MAC Interface - Evaluation Board RoHS:否 制造商:Micrel 产品:Evaluation Boards 类型:Ethernet Transceivers 工具用于评估:KSZ8873RLL 接口类型:RMII 工作电源电压:
KSZ8864RMNI 功能描述:以太网 IC 4-Port 10/100 Ethernet Switch w/ 2x PHYs and 2x MAC Interface - Industrial Temp RoHS:否 制造商:Micrel 产品:Ethernet Switches 收发器数量:2 数据速率:10 Mb/s, 100 Mb/s 电源电压-最大:1.25 V, 3.45 V 电源电压-最小:1.15 V, 3.15 V 最大工作温度:+ 85 C 封装 / 箱体:QFN-64 封装:Tray
KSZ8864RMNU 功能描述:以太网 IC 4-Port 10/100BT Switch with MII/RMII (Automotive) RoHS:否 制造商:Micrel 产品:Ethernet Switches 收发器数量:2 数据速率:10 Mb/s, 100 Mb/s 电源电压-最大:1.25 V, 3.45 V 电源电压-最小:1.15 V, 3.15 V 最大工作温度:+ 85 C 封装 / 箱体:QFN-64 封装:Tray