PRELIMINARY
INVERSE MULTIPLEXING OVER ATM
PM7340 S/UNI-IMA-8
DATA SHEET
PMC-2001723
ISSUE 3
INVERSE MULTIPLEXING OVER ATM
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
170
This field is set and changed using the
update_test_ptn PM command.
This field will remain at its current value
during a group-restart.
7:0
TX_TX_TEST_PTN
Tx test pattern field to be sent in the
transmit ICP cell.
This field is set and changed using the
update_test_ptn PM command.
This field will remain at its current value
during a group-restart.
4
31:0
TX_PHY_VALID
32 bit vector in which each bit
corresponds to one TX physical link in
TX_PHY_TABLE (which is located in
TIMA group context memory).
“0”: table entry not valid
“1”: table entry valid (physical link
pointed by the corresponding
TX_PHY_TABLE entry has been
assigned to the current group.)
This field will remain at its current value
during a group-restart.
5
31:0
TX_LASR_ACT
32 bit vector in which each bit
corresponds to one TX physical link in
TX_PHY_TABLE (which is located in
TIMA group context memory).
“0”: the link is not involved in LASR.
“1”: the link is currently involved in a
active LASR procedure.
6
31:30
RESERVED
29
RX_FE_INFO_VALI
D
This indicates whether the context data
fields captured from incoming ICP
cells) or not.
‘0’: Invalid.
‘1’: Valid.