PRELIMINARY
INVERSE MULTIPLEXING OVER ATM
PM7340 S/UNI-IMA-8
DATA SHEET
PMC-2001723
ISSUE 3
INVERSE MULTIPLEXING OVER ATM
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
301
Symbol
V
VDDI
V
VDDO
V
VDDQ
V
IL
Parameter
Power Supply
Power Supply
Power Supply
Input Low Voltage
Min
1.656
3.03
3.03
0
Typ
1.8
3.3
3.3
Max
1.944
3.56
3.56
0.8
Units
Volts
Volts
Volts
Volts
Conditions
Guaranteed Input
Low voltage.
Guaranteed Input
High voltage.
Guaranteed output
Low voltage at
VDD=3.03V and
I
OL
=maximum rated
for pad.
Guaranteed output
High voltage at
VDD=3.03V and
I
OH
=maximum rated
current for pad.
Applies to RSTB and
TRSTB only.
Applies to RSTB and
TRSTB only.
Applies to RSTB and
TRSTB only.
V
IH
Input High Voltage
2.0
Volts
V
OL
Output or Bi-
directional Low
Voltage
TBD
0.4
Volts
V
OH
Output or Bi-
directional High
Voltage
2.4
TBD
Volts
V
T+
Reset Input High
Voltage
Reset Input Low
Voltage
Reset Input
Hysteresis
Voltage
Input Low Current
2.0
Volts
V
T-
0.8
Volts
V
TH
TBD
Volts
I
ILPU
10
100
μA
VIL = GND. Notes 1
and 3.
VIH = V
DD
. Notes 1
and 3.
VIL = GND. Notes 2
and 3.
VIH = V
DD
. Notes 2
and 3.
t
A
=25°C, f = 1 MHz
t
A
=25°C, f = 1 MHz
I
IHPU
Input High Current
-10
0
+10
μA
I
IL
Input Low Current
-10
0
+10
μA
I
IH
Input High Current
-10
0
+10
μA
C
IN
C
OUT
Input Capacitance
Output
Capacitance
5
5
pF
pF