W39V040A
- 16 -
6.20 Software Product Identification and Boot Block Lockout Detection Acquisition
Flow
Product
Identification
Entry (1)
Load data 55
to
address 2AAA
Load data 90
to
address 5555
Pause 10 S
Product
Identification
and Boot Block
Lockout Detection
Mode (3)
Read address = 00000
data = DA
Read address = 00001
data = 3D
Read address = 00002
DQ0/DQ1 of data outputs
= 1/0
(4)
Product
Identification Exit (6)
Load data 55
to
address 2AAA
Load data F0
to
address 5555
Normal Mode
(5)
(2)
Load data AA
to
address 5555
μ
Load data AA
to
address 5555
Pause 10 S
μ
Notes for software product identification/boot block lockout detection:
(1) Data Format: DQ7
DQ0 (Hex); Address Format: A14 A0 (Hex)
(2) A1
A18 = VIL; manufacture code is read for A0 = VIL; device code is read for A0 = VIH.
(3) The device does not remain in “identification and boot block lockout detection” mode if power down.
(4) The DQ[3:0] to indicate the sectors protect status as below:
DQ0
DQ1
DQ2
DQ3
0
64Kbytes Boot Block
Unlocked by Software
16Kbytes Boot Block
Unlocked by Software
64Kbytes Boot Block Unlocked
by #TBL hardware trapping
Whole Chip Unlocked by #WP
hardware trapping Except Boot
Block
1
64Kbytes Boot Block
Locked by Software
16Kbytes Boot Block
Locked by Software
64Kbytes Boot Block Locked
by #TBL hardware trapping
Whole Chip Locked by #WP
hardware trapping Except Boot
Block
(5) The device returns to standard operation mode.
(6) Optional 1-write cycle (write F0 hex at XXXX address) can be used to exit the “product identification/boot block lockout
detection.”