X1203
Characteristics subject to change without notice.
6 of 19
REV 1.2.0 2/13/01
www.xicor.com
RTCF: Real Time Clock Fail Bit—Volatile
This bit is set to a ‘1’ after a total power failure. This is a
read only bit that is set by hardware when the device
powers up after having lost all power to the device. The
bit is set regardless of whether VCC or VBACK is
applied rst. The loss of one or the other supplies does
not result in setting the RTCF bit. The rst valid write to
the RTC (writing one byte is sufcient) resets the
RTCF bit to ‘0’.
Unused Bits
These devices do not use bits 3 or 4, but must have a
zero in these bit positions. The data byte output during
a SR read will contain zeros in these bit locations.
CONTROL REGISTERS
Interrupt Control Bits (AL1E, AL0E)
There are two interrupt control bits, Alarm 1 Interrupt
Enable (AL1E) and Alarm 0 Interrupt Enable (AL0E) to
specically enable or disable the alarm interrupt signal
output. The interrupt output is enabled when either bit
is set to ‘1’. Two volatile bits (AL1 and AL0), associated
with these alarms, indicate if an alarm has happened.
These bits are set on an alarm condition regardless of
whether the alarm interrupts are enabled. The AL1 and
AL0 bits are reset by the falling edge of the 8th clock of
a read of the register containing the bits.
In an alternative mode (called pulsed interrupt mode),
controlled by an interrupt mode (IM) bit, the alarm 0
setting provides an output pulse on IRQ each time the
alarm matches the RTC. In this case the AL0 bit is not
used. Alarm 1 works as before (i.e. the AL1 bit is set
when an alarm occurs), but it is necessary to poll the
status register to determine whether a match has
occurred. This read operation is necessary to reset the
AL1 ag.
Normal Mode (IM Bit = 0)
A match of the RTC and the contents of the alarm 0
registers automatically sets the AL0 bit. If the AL0E bit
is also set, the output IRQ signal goes active (LOW). If
the AL0E bit is not set, the AL0 bit is set, but the IRQ
signal remains unchanged.
A match of the RTC and the contents of the alarm 1
registers automatically sets the AL1 bit. If the AL1E bit
is also set, the output IRQ signal goes active (LOW). If
the AL1E bit is not set, the AL1 bit is set, but the IRQ
signal remains unchanged.
Reading the status register, containing the AL0 and
AL1 bits, resets the bits. The bits do not reset until the
falling edge of the 8th output clock of the status register
containing the alarm bits. When the bits reset, the out-
put IRQ signal returns to the inactive state.
Pulsed Interrupt Mode (IM Bit = 1)
In this mode, the alarm interrupt enable bits (AL0E and
AL1E) are not used. Alarm 1 operates as before, so a
match of the RTC and alarm 1 sets the AL1 bit. Since
the interrupt enable bits have no function, it is neces-
sary for the host processor to poll the AL1 bit to deter-
mine if an alarm has occurred.
Alarm 0 provides an output response. In this case,
when the RTC matches the alarm 0 registers, the out-
put IRQ pulses one time. This pulse can be used to
control some outside circuit or event, without the need
for a local processor. The pulse is about 30ms in dura-
tion. All alarm 0 mask options are available, so this
becomes a very exible long term repeat trigger.
WRITING TO THE CLOCK/CONTROL REGISTERS
Changing any of the nonvolatile bits of the clock/control
register requires the following steps:
– Write a 02h to the status register to set the Write
Enable Latch (WEL). This is a volatile operation, so
there is no delay after the write. (Operation pre-
ceeded by a start and ended with a stop.)
– Write a 06h to the status register to set both the Reg-
ister Write Enable Latch (RWEL) and the WEL bit.
This is also a volatile cycle. The zeros in the data
byte are required. (Operation preceeded by a start
and ended with a stop.)
– Write one to 8 bytes to the clock/control registers
with the desired clock, alarm, or control data. This
sequence starts with a start bit, requires a slave byte
of “11011110” and an address within the CCR and is
terminated by a stop bit. A write to the CCR changes
EEPROM values so these initiate a nonvolatile write
cycle and will take up to 10ms to complete. Writes to
undened areas have no effect. The RWEL bit is
reset by the completion of a nonvolatile write cycle,
so the sequence must be repeated to again initiate
another change to the CCR contents. If the
sequence is not completed for any reason (by send-
ing an incorrect number of bits or sending a start
instead of a stop, for example) the RWEL bit is not
reset and the device remains in an active mode.
相关PDF资料
PDF描述
X1228S14I-2.7 1 TIMER(S), REAL TIME CLOCK, PDSO14
X25644S14-1.8T1 SPECIALTY MICROPROCESSOR CIRCUIT, PDSO14
X502 MALE, MULTIWAY RACK AND PANEL CONN, SOLDER
X503 MALE, MULTIWAY RACK AND PANEL CONN, SOLDER
X504 MALE, MULTIWAY RACK AND PANEL CONN, SOLDER
相关代理商/技术参数
参数描述
X1203V8 制造商:Intersil Corporation 功能描述:
X-120-499 制造商:Brady Corporation 功能描述:VIAL SIDE/TOP COMBO-B499 .50X1X.375DIA
X1205 制造商:XICOR 制造商全称:Xicor Inc. 功能描述:Real Time Clock/Calendar
X1205S8 功能描述:IC RTC/CALENDAR 2-WIRE 8-SOIC RoHS:否 类别:集成电路 (IC) >> 时钟/计时 - 实时时钟 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- 类型:时钟/日历 特点:警报器,闰年,SRAM 存储容量:- 时间格式:HH:MM:SS(12/24 小时) 数据格式:YY-MM-DD-dd 接口:SPI 电源电压:2 V ~ 5.5 V 电压 - 电源,电池:- 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:8-WDFN 裸露焊盘 供应商设备封装:8-TDFN EP 包装:管件
X1205S8I 功能描述:IC RTC/CALENDAR 2-WIRE 8-SOIC RoHS:否 类别:集成电路 (IC) >> 时钟/计时 - 实时时钟 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- 类型:时钟/日历 特点:警报器,闰年,SRAM 存储容量:- 时间格式:HH:MM:SS(12/24 小时) 数据格式:YY-MM-DD-dd 接口:SPI 电源电压:2 V ~ 5.5 V 电压 - 电源,电池:- 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:8-WDFN 裸露焊盘 供应商设备封装:8-TDFN EP 包装:管件