CS5460A
Note that when the calibration command is sent to
the CS5460A, the device must not be performing
A/D conversions (in either of the two acquisitions
modes). If the CS5460A is running A/D conver-
sions/computations in the ‘continuous computation
cycles’ acquisition mode (C = 1), the Pow-
er-Up/Halt Command must be issued first to termi-
nate A/D conversions/computations. If the
CS5460A is running A/D conversions/computa-
tions in the ‘single computation cycle’ data acquisi-
tion mode (C = 0), the Power-Up/Halt Command
must be issued first (unless the computation cycle
has completed) before executing any calibration
sequence. The calibration sequences will not run
if the CS5460A is running in either of the two avail-
able acquisition modes.
3.8.4 Calibration Signal Input Level
For both the voltage and current channels, the dif-
ferential voltage levels of the calibration signals
must be within the specified voltage input limits (re-
fer to “Differential Input Voltage Range” in Section
age channel the peak differential voltage level can
never be more than 500 mV P-P . The same is true
for the current channel if the current channel input
PGA is set for 10x gain. If the the current channel’s
PGA gain is set to 50x, then the current channel’s
input limits are 1 00 mV P-P .
Note that for the AC/DC gain calibrations, there is
an absolute limit on the RMS/DC voltage levels (re-
spectively) that are selected for the voltage/current
channel gain calibration input signals. The maxi-
mum value that the gain register can attain is 4.
Therefore, for either channel, if the voltage level of
a gain calibration input signal is low enough that it
causes the CS5460A to attempt to set either gain
register higher than 4, the gain calibration result
will be invalid, and after this occurs, all CS5460A
results obtained when the part is running A/D con-
versions will be invalid.
3.8.5 Calibration Signal Frequency
The frequency of the calibration signals must be
less than 1 kHz (assume MCLK/K = 4.096 MHz
and K = 1). Optimally, the frequency of the calibra-
tion signal will be at the same frequency as the fun-
damental power line frequency of the power
system that is to be metered.
DS487F5
3.8.6 Input Configurations for Calibrations
Figure 16 shows the basic setup for gain calibra-
tion. If a DC gain calibration is desired, a positive
DC voltage level must be applied, such that it truly
represents the absolute maximum peak instanta-
neous voltage level that needs to be measured
across the inputs (including the maximum
over-range level that must be accurately mea-
sured). In other words, the input signal must be a
positive DC voltage level that represents the de-
sired absolute peak full-scale value. However, in
many practical power metering situations, an AC
signal is preferred over a DC signal to calibrate the
gain. To perform AC gain calibration instead of DC,
an AC reference signal should be applied that is
set to the desired maximum RMS level. Because
the voltage/current waveforms that must be mea-
sured in most power systems are approximately si-
nusoidal in nature, the RMS levels of the AC gain
calibration input signals may need to be set signif-
icantly lower than the voltage/current channel’s
maximum DC voltage input level. This must be
done in order to avoid the possibility that the peak
values of the AC waveforms that are to be mea-
sured will not register a value that would be outside
the available output code range of the voltage/cur-
rent A/D converters. For example, on the voltage
channel, if the Voltage Channel Gain Register is
set to it’s default power-on value of 1.000... before
calibration, then the largest pure sinusoidal wave-
form that can be used in AC calibration is one
whose RMS-value is ~0.7071 of the value of the
voltage channel’s peak DC input voltage value of
500 mV P-P . Thus the maximum value of the input
sinusoid would be ~176.78 mV (rms). But in many
practical power metering situations, the RMS volt-
age input level of the AC gain calibration signal
may be reduced even further, to allow for some
over-ranging capability. A typical sinusoidal cali-
bration value which allows for reasonable
over-range margin would be 0.6 of the voltage/cur-
rent channel’s maximum input voltage level. For
the voltage channel, such a sine-wave would have
a value of 0.6 x 250 mV rms = 150 mV rms .
For the offset calibrations, there is no difference
between the AC and DC calibration signals that
must be supplied: simply connect the “+” and “-’
29
相关PDF资料
PDF描述
T95Z156K020ESSL CAP TANT 15UF 20V 10% 2910
DFN0.83BK DURA-FLEX .83" BLACK 100'
MAX6983AUG+ IC LED DRIVER LINEAR 24-TSSOP
VI-J5H-CX-F4 CONVERTER MOD DC/DC 52V 75W
RSM40DTAD-S189 CONN EDGECARD 80POS R/A .156 SLD
相关代理商/技术参数
参数描述
CS5460A-BSZ 制造商:Cirrus Logic 功能描述:Driver IC 制造商:Cirrus Logic 功能描述:IC ENERGY METERING 1PHASE 24SSOP 制造商:Cirrus Logic 功能描述:IC, ENERGY METERING, 1PHASE, 24SSOP
CS5460A-BSZR 功能描述:电流和电力监控器、调节器 IC Sngl-Phs BiDirect PWR/Energy RoHS:否 制造商:STMicroelectronics 产品:Current Regulators 电源电压-最大:48 V 电源电压-最小:5.5 V 工作温度范围:- 40 C to + 150 C 安装风格:SMD/SMT 封装 / 箱体:HPSO-8 封装:Reel
CS5460-BS 制造商:Rochester Electronics LLC 功能描述:- Bulk 制造商:Cirrus Logic 功能描述:
CS5460C-ISZ 功能描述:电流和电力监控器、调节器 Sngl-Phs Bi-Drctnl Power/Energy RoHS:否 制造商:STMicroelectronics 产品:Current Regulators 电源电压-最大:48 V 电源电压-最小:5.5 V 工作温度范围:- 40 C to + 150 C 安装风格:SMD/SMT 封装 / 箱体:HPSO-8 封装:Reel
CS5460C-ISZR 功能描述:电流和电力监控器、调节器 IC Sngl-Phs BiDirect PWR/Energy RoHS:否 制造商:STMicroelectronics 产品:Current Regulators 电源电压-最大:48 V 电源电压-最小:5.5 V 工作温度范围:- 40 C to + 150 C 安装风格:SMD/SMT 封装 / 箱体:HPSO-8 封装:Reel