参数资料
型号: LD4006P0
厂商: Red Lion Controls
文件页数: 9/16页
文件大小: 0K
描述: COUNTER 6 DIGIT DUAL 4.0" RED
标准包装: 1
系列: LD
计数速率: 35kHz
数字/字母数: 6
输入类型: 电压、开关外壳、晶体管开关
输出类型: 继电器和 RS232/RS485
电源电压: 11 V ~ 16 VDC,85 V ~ 250 VAC
显示器类型: LED 红
5.2 MODULE 2 - R ATE S ETUP P ARAMETERS ( ?????? )
2-rAtE
PAR
PARAMETER MENU
Pro
rt-Enb
Rate
Enable
rt-dPt
Rate Decimal
Point
StYLE
Rate Input
Scaling Style
rt-dSP
Rate Scaling
Display Value
rt-INP
Rate Scaling
Input Value
LO-Udt
Rate Low
Update Time
HI-Udt
Rate High
Update Time
RATE ENABLE
RATE LOW UPDATE TIME (DISPLAY UPDATE)
?????? ?
? ??
??
???
?????? ?
? ????
???? to ? ????? seconds
This parameter enables the rate display. For maximum input frequency, Rate
Enable should be set to ?? when not in use. When set to ?? , the remaining rate
parameters are not accessible.
RATE DECIMAL POINT
The Low Update Time is the minimum amount of time between display
updates for the Rate display. Values of 0.1 and 0.2 seconds will update the
display correctly but may cause the display to appear unsteady.
RATE HIGH UPDATE TIME (DISPLAY ZERO)
?????? ?
? ?
?
???
????
?????
??????
?????? ?
? ????
???? to ? ????? seconds
This selects the decimal point position for rate displays and any setpoint value
assigned to these displays. This parameter does not affect rate scaling calculations.
The High Update Time is the maximum amount of time before the Rate
display is forced to zero. (For more explanation, refer to Rate Value
Calculation.) The High Update Time must be higher than the Low Update Time
and higher than the desired slowest readable speed (one divided by pulses per
?????
?
RATE INPUT SCALING STYLE
? ??? ????
???
second). The factory setting of 2.0, will force the display to zero for speeds
below 0.5 Hz or a pulse every 2 seconds.
If a Rate Input value (in Hz) and the corresponding Rate Display value are
known, the Key-in ( ??? ) Scaling Style can be used. This allows rate scaling
without the presence of a rate input signal.
If the Rate Input value has to be derived from the actual rate input signal, the
Apply ( ???? ) Scaling Style should be used.
RATE SCALING DISPLAY VALUE
SCALING FOR RATE INDICATION
To scale the Rate, enter a Scaling Display value with a corresponding Scaling
Input value. These values are internally plotted to a Display value of 0 and Input
value of 0.0 Hz. A linear relationship is formed between these points to yield a
rate display value that corresponds to the incoming input signal rate. The meter
is capable of showing a rate display value for any positive slope linear process.
SCALING CALCULATION FOR KEY-IN STYLE
?????? ?
? ??????
?? to ? ??????
If a display value versus input signal (in pulses per second) is known, then
those values can be entered into Scaling Display ( ?????? ) and Scaling Input
( ?????? ). No further calculations are needed.
If only the number of pulses per ‘single’ unit (i.e. # of pulses per foot) is
Enter the desired Rate Display value for the Scaling Point. This value is
entered using the front panel buttons for either Scaling Style.*
known, then it can be entered as the Scaling Input value and the Scaling Display
value will be entered as the following:
RATE PER
Second
DISPLAY ( ?????? )
1
INPUT ( ?????? )
# of pulses per unit
RATE SCALING INPUT VALUE
Minute
60
# of pulses per unit
?????? ?
???? to ? ???????
Hour
3600
# of pulses per unit
? ???????
Enter the corresponding Rate Input value using the Scaling Style selected. *
Key-in Style:
Enter the Rate Input value using the front panel buttons. This value is always
in pulses per second (Hz).*
Apply Style:
The meter initially shows the stored Rate Input value. To retain this value,
press PAR to advance to the next parameter. To enter a new value, apply the rate
input signal to Input A. Press RST ? and the applied input frequency (in Hz) will
appear on the display. To insure the correct reading, wait several rate sample
periods (see Rate Low Update Time) or until a consistent reading is displayed.
Press PAR to store the displayed value as the new Rate Input value.
NOTES:
1. If # of pulses per unit is less than 1, then multiply both Input and Display
values by 10 or 100 as needed for greater accuracy.
2. If the Display value is raised or lowered, then Input value must be raised
or lowered by the same proportion (i.e. Display value for per hour is
entered by a third less (1200) then Input value is a third less of # of pulses
per unit). The same is true if the Input value is raised or lowered, then
Display value must be raised or lowered by the same proportion.
3. Both values must be greater than 0.
EXAMPLE:
1. With 15.1 pulses per foot, show feet per minute in tenths. Scaling Display
= 60.0 Scaling Input = 15.1.
2. With 0.25 pulses per gallon, show whole gallons per hour. (To have greater
accuracy, multiply both Input and Display values by 10.) Scaling Display
= 36000 Scaling Input = 2.5.
*For value entry instructions, refer to selection/value entry in the Programming
The Meter section.
9
相关PDF资料
PDF描述
LD412460 DIODE MOD ISO DUAL 2400V 600A
LIRT220A CONTROL RELAY CURRENT 220VAC
LNXC2000 COUNTER DUAL PRESET 115VAC
LP-56-850 XFRMR 115/230V 28V 1.7A 48VA PCB
LS412460 DIODE MOD ISO SGL 2400V 600A
相关代理商/技术参数
参数描述
LD400-AC 制造商:MRV 制造商全称:MRV 功能描述:LambdaDriver Chassis - DWDM/CWDM Platform
LD400-DC 制造商:MRV 制造商全称:MRV 功能描述:LambdaDriver Chassis - DWDM/CWDM Platform
LD400L-2AC 制造商:MRV 制造商全称:MRV 功能描述:LambdaDriver Chassis - DWDM/CWDM Platform
LD400L-2DC 制造商:MRV 制造商全称:MRV 功能描述:LambdaDriver Chassis - DWDM/CWDM Platform
LD400L-AC 制造商:MRV 制造商全称:MRV 功能描述:LambdaDriver Chassis - DWDM/CWDM Platform