参数资料
型号: MA17501
厂商: Dynex Semiconductor Ltd.
英文描述: Radiation Hard MIL-STD-1750A Execution unit
中文描述: 辐射硬的MIL - STD - 1750A执行单元
文件页数: 10/35页
文件大小: 431K
代理商: MA17501
MA17501
10/35
3.6.4 Privileged Instruction Fault (PIFN)
lnput. PlFN low is an indication to the Execution Unit that a
fault, requiring the current MlL-STD-1750A instruction to be
aborted, has occurred. The faults that cause the instruction
abort are 0, 5, and 8 which are, respectively, memory protect
error ((IU)MPROEN low), an out-of-bounds memory/input-
output address ((lU)EXADE low), or a bus fault timeout. ln
response to PIFN low, the EU maintains AS low, DSN high,
and forces the M/lON signal high for two machine cycles. ln
addition, the EU will internally complete the current SYNCN
cycle and resume operation. This allows the Control Unit to
sequence to the interrupt handling routine without affecting the
bus status.
3.6.5 Branch or Jump Control (T1)
Output. The Execution Unit raises the T1 signal high to
indicate a microcode conditional branch condition is true. The
Control Unit accepts T1 and feeds it into the microcode
address multiplexer where microinstruction branches are
effected.
3.6.6 Test Microword (TESTN)
lnput. The TESTN signal is used during chip test to load 40-
bit microinstructions into the EU execution register. TESTN
low loads E39 (MSB) to E20, and TESTN high loads E19 to
E00 (LSB). TESTN should be pulled-up to VDD in customer
applications.
4.0 OPERATING MODES
The following discussions detail the MAS281 chip set
operating modes from the perspective of the Execution Unit.
MAS281 operating modes involving the MA17501 include: (1)
Initialisation, (2) lnstruction Execution, (3) Interrupt Servicing,
(4) Fault Servicing, (5) DMA Support, and (6) Software
Development Support.
4.1 INITIALISATION
RESET starts the chip set microcoded initialisation
sequence, but also affects the Execution Unit Circuitry directly.
When RESET is raised high, the Hold state acknowledge
signal (HLDAKN) is forced high thus releasing the MAS281
from the Hold state (if changing HOLDN is unable to release
the Hold state). RESET also forces the clock generation
circuitry to create a five OSC period machine cycle by
disabling state machine inputs that vary the machine cycle
length.
Upon releasing RESET, the EU Hold State circuitry is
enabled and the clock generation circuitry is allowed to
function normally. HOLDN will not have an effect on chip set
operation until the initialisation routine has completed because
the microcode branch to the Hold routine is disabled.
The microcoded initialisation routine clears the lnstruction
Counter (lC), Status Word Register (SW), and Register File
(R00-R15) and performs the BlT. The successful completion of
the BlT is necessary to guarantee the register file is cleared at
the end of the initialisation routine.
The microcoded BIT exercises all legal microinstruction bit
combinations and tests all internally accessible structures of
the MAS281. For the Execution Unit this includes the full
Register Set, ALU, Multiplier, Barrel Shifter, and Macroflag
logic. Table 2 details the tests performed by each of the five
BlT subroutines.
lf any part of BlT fails, an error code identifying the failed
subroutine is loaded into the lnterrupt Unit Fault Register (via
the AD Bus), BlT is aborted, and NPU is left in the low state.
Table 2 defines the coding of the BlT results. (lNTREN enables
microcode control of the lnterrupt Unit (lU) to raise NPU high (if
BlT passes) and load BIT error codes (if BIT fails) into the lU
Fault Register).
The last action performed by the initialisation routine is to
load the instruction pipeline. Instruction fetches start at
memory location zero (page zero) from the Start-Up ROM (if
implemented). Whether or not BIT passes, the processor will
begin instruction execution at this point.
[NOTE: To complete initialisation and pass BIT, interrupt
and fault inputs must be high for the duration of the
initialisation routine. Also, the Timers A and B must be clocked
for BlT success.]
相关PDF资料
PDF描述
MA17502 Radiation Hard MIL-STD-1750A Control Unit
MA17503 Radiation Hard MIL-STD-1750A Interrupt Unit
MA1916 Radiation Hard Reed-Solomon & Convolution Encoder
MA28139 OBDH Bus Terminal
MA28140 Packet Telecommand Decoder
相关代理商/技术参数
参数描述
MA17502 制造商:DYNEX 制造商全称:Dynex Semiconductor 功能描述:Radiation Hard MIL-STD-1750A Control Unit
MA17503 制造商:DYNEX 制造商全称:Dynex Semiconductor 功能描述:Radiation Hard MIL-STD-1750A Interrupt Unit
MA1751E12B1+6-FSR-EM 制造商:Mechatronics Fan Group 功能描述:
MA1751E12B-FSR 功能描述:FAN AXIAL 172X150X51MM 12VDC 制造商:mechatronics fan group 系列:MA1751 零件状态:有效 电压 - 额定:12VDC 大小/尺寸:矩形/圆形 - 172mm 长 x 150mm 高 宽度:50.80mm 气流:269.2 CFM(7.62m3/min) 静压力:0.670 英寸水柱(166.9 Pa) 轴承类型:滚珠 风扇类型:管轴式 特性:- 噪声:61 dB(A) 功率(W):- RPM:3150 RPM 端接:2 引线 侵入防护:- 工作温度:- 认可:UL 额定电流:2.2A 电压范围:- 材料 - 框架:铝 材料 - 刀片:聚对苯二甲酸丁二酯(PBT) 重量:1.6 磅(725.7g) 标准包装:20
MA1751E24B-FSR 功能描述:AXIAL FAN 172X150X51MM 24VDC 制造商:mechatronics fan group 系列:* 零件状态:在售 标准包装:1