ZL30402
Data Sheet
29
Zarlink Semiconductor Inc.
5.1.2
Single Reference Operation: NORMAL --> AUTO HOLDOVER --> NORMAL
The NORMAL to AUTO-HOLDOVER to NORMAL transition will usually happen when the Network Element loses
its single reference clock unexpectedly or when it has two references but switching to the secondary reference is
not a desirable option (unless primary reference is lost without chance of quick recovery).
The sequence starts with the unexpected failure of a reference signal shown as transition OK --> FAIL in Figure 7
"Transition from Free-Run to Normal Mode" at a time when ZL30402 operates in Normal mode. This failure is
detected by the active Acquisition PLL based on the following FAIL criteria:
Frequency offset on 8 kHz, 1.544 MHz, 2.048 MHz and 19.44 MHz reference clocks exceeds ±30000 ppm
(±3%).
Single phase hit on 1.544 MHz, 2.048 MHz and 19.44 MHz exceeds half of the cycle of the reference clock.
After detecting any of these anomalies on a reference clock the Acquisition PLL will switch itself into Holdover mode
forcing the Core PLL to automatically switch into the Auto Holdover state. This condition is flagged by LOCK = 0
and HOLDOVER = 1.
Figure 8 - Automatic Entry into Auto Holdover State and Eecovery into Normal mode
There are two possible returns to Normal mode after the reference signal is restored:
With the AHRD (Automatic Holdover Return Disable) bit set to 0. In this case the Core PLL will automatically
return to the Normal state after the reference signal recovers from failure. This transition is shown on the
state diagram as a FAIL --> OK change. This change becomes effective when the reference is restored and
there have been no phase hits detected for at least 64 clock cycles for 1.544/2.048 MHz reference, 512
clock cycles for 19.44 MHz reference and 1 clock cycle for 8 kHz reference.
With the AHRD bit set to high to disable automatic return to Normal and the change of MHR (Manual
Holdover Release) bit from 0 to 1 to trigger the transition from Auto Holdover to Normal. This option is
provided to protect the Core PLL against toggling between Normal and Auto Holdover states in case of an
intermittent quality reference clock. In the case when MHR has been changed when the reference is still not
available (Acquisition PLL in Holdover mode) the transition to Normal state will not occur and MHR 0 to 1
transition must be repeated.
This transition from Auto Holdover to Normal mode is performed as “hitless” reference switching.
NORMAL
(LOCKED)
00
AUTO
HOLD-
OVER
HOLD-
OVER
01
FREE-
RUN
10
RESET
Ref: OK &
MS2, MS1 == 00
{AUTO}
Ref: OK --> FAIL &
MS2, MS1 == 00
{AUTO}
MS2, MS1 == 01 OR
RefSel change
Ref: FAIL --> OK &
MS2, MS1 == 00 &
AHRD=1 &
MHR=0 -->1 then 1-->0
{MANUAL}
Ref: FAIL --> OK &
MS2, MS1 == 00 &
AHRD=0
{AUTO}
MS2, MS1 == 10 forces
unconditional return from
any state to Free-run
MS2, MS1! = 10
RESET == 1
RefSel Change
Automatic return to NORMAL: AHRD=0
OR
Manual return to NORMAL: AHRD=1 & MHR= 0-->1 then 1-->0
相关PDF资料
PDF描述
ZL30402/QCG1 ATM/SONET/SDH SUPPORT CIRCUIT, PQFP80
ZL50112GAG2 SPECIALTY TELECOM CIRCUIT, PBGA552
ZL50112GAG SPECIALTY TELECOM CIRCUIT, PBGA552
ZL50114GAG2 SPECIALTY TELECOM CIRCUIT, PBGA552
ZL50114GAG SPECIALTY TELECOM CIRCUIT, PBGA552
相关代理商/技术参数
参数描述
ZL30402QCG1 制造商:Microsemi Corporation 功能描述:PB FREE SONET / SDH NETWORK ELEMENT PLL - Trays 制造商:MICROSEMI CONSUMER MEDICAL PRODUCT GROUP 功能描述:IC NETWORK PLL SONET/SDH 80LQFP 制造商:Microsemi Corporation 功能描述:IC NETWORK PLL SONET/SDH 80LQFP
ZL30406 制造商:ZARLINK 制造商全称:Zarlink Semiconductor Inc 功能描述:SONET/SDH Clock Multiplier PLL
ZL30406_06 制造商:ZARLINK 制造商全称:Zarlink Semiconductor Inc 功能描述:SONET/SDH Clock Multiplier PLL
ZL30406QGC 制造商:Zarlink Semiconductor Inc 功能描述:PLL CLOCK MLTPLR SGL UP TO 19.44MHZ 64TQFP - Trays
ZL30406QGC1 制造商:ZARLINK 制造商全称:Zarlink Semiconductor Inc 功能描述:SONET/SDH Clock Multiplier PLL