71M6543F/71M6543G Data Sheet
number of LCD segments and DIO pins can be implemented in software to accommodate various
requirements.
In addition to the temperature-trimmed ultra-precision voltage reference, the on-chip digital temperature
compensation mechanism includes a temperature sensor and associated controls for correction of unwanted
temperature effects on metrology and RTC accuracy (i.e., to meet the requirements of ANSI and IEC
standards). Temperature-dependent external components such as the crystal oscillator, current
transformers (CTs), Current Shunts and their corresponding signal conditioning circuits can be character-
ized and their correction factors can be programmed to produce electricity meters with exceptional accuracy
over the industrial temperature range.
One of the two internal UARTs is adapted to support an Infrared LED with internal drive and sense
configuration and can also function as a standard UART. The optical output can be modulated at 38 kHz.
This flexibility makes it possible to implement AMR meters with an IR interface. A block diagram of the IC
is shown in Figure 1 .
2.2
Analog Front-End (AFE)
The AFE functions as a data acquisition system, controlled by the MPU. The 71M6543 AFE may also be
augmented by isolated 71M6xx3 sensors in order to support low-cost current shunt sensors. Figure 2 ,
and Figure 3 show the two most common configurations; other configurations are possible. Sensors that
are connected directly to the 71M6543 (i.e., IADC0-IADC1, VADC8, VADC9 and VADC10) are
multiplexed into the single second-order sigma-delta ADC input for sampling in the 71M6543. The
71M6543 ADC output is decimated by the FIR filter and stored in CE RAM where it can be accessed and
processed by the CE.
Shunt current sensors that are isolated by using a 71M6xx3 device, are sampled by a second-order
sigma delta ADC in the 71M6xx3 and the signal samples are transferred over the digital isolation interface
through the low-cost isolation pulse transformer.
Figure 2 shows the 71M6543 using shunt current sensors and the 71M6xx3 isolated sensor devices.
Figure 2 supports neutral current measurement with a local shunt connected to the IADC0-IADC1 input
plus three remote (isolated) shunt sensors. As seen in Figure 2 , when a remote isolated shunt sensor is
connected via the 71M6xx3, the samples associated with this current channel are not routed to the
multiplexer, and are instead transferred digitally to the 71M6543 via the isolation interface and are directly
stored in CE RAM. The MUX_SELn[3:0] I/O RAM control fields allow the MPU to configure the AFE for the
desired multiplexer sampling sequence. Refer to Table 1 and Table 2 for the appropriate CE code and the
corresponding AFE settings.
See Figure 31 for the meter wiring configuration corresponding to Figure 2 .
IN*
VREF
Local
Shunt
IADC0
IADC1
VADC8 (VA)
MUX
VREF
VADC
?Σ ADC
CONVERTER
VREF
FIR
22
VADC9 (VB)
IA
VADC10 (VC)
Remote
Shunt
INP
71M6xx3
SP
S N
IADC2
IADC3
22
INN
IB
CE RAM
Remote
Shunt
INP
INN
71M6xx3
SP
S N
IADC4
IADC5
Digital
Isolation
Interface
22
IC
Remote
Shunt
INP
71M6xx3
SP
S N
IADC6
IADC7
22
INN
*IN = Neutral Current
71M6543
9/17/2010
Figure 2: AFE Block Diagram (Shunts: One-Local, Three-Remotes)
12
v2
相关PDF资料
PDF描述
R1S-0524/HP CONV DC/DC 1W 05VIN 24VOUT
SS10P3CL-M3/87A DIODE SCHOTTKY 10A 30V SMPC
ISL6549CRZ IC REG DL BCK/LINEAR SYNC 16-QFN
ISL6549IRZ-T IC REG DL BCK/LINEAR SYNC 16-QFN
AMC40DRTF CONN EDGECARD 80POS .100 DIP SLD
相关代理商/技术参数
参数描述
71M6543FT-IGT/F 制造商:Maxim Integrated Products 功能描述:ENERGY METER ICS - Rail/Tube
71M6543FT-IGTR/F 制造商:Maxim Integrated Products 功能描述:3-PHASE SOC, 64KB FLASH, PRES TEMP SENSOR - Tape and Reel
71M6543G 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Selectable Gain of 1 or 8 for One Current Energy Meter ICs Metrology Compensation
71M6543GH 制造商:未知厂家 制造商全称:未知厂家 功能描述:电表IC
71M6543GHT-IGT/F 制造商:Maxim Integrated Products 功能描述:3-PHASE, 128KB, PRES TEMP SENSOR, HI PREC - Bulk