71M6543F/71M6543G Data Sheet
If TEMP_PWR selects VBAT_RTC when the battery is nearly discharged, the temperature measurement
may not finish. In this case, firmware may complete the measurement by selecting V3P3D
( TEMP_PWR = 1).
Table 45: I/O RAM Registers for Temperature and Battery Measurement
Name
TBYTE_BUSY
Location
28A0[3]
Rst
0
Wk
0
Dir
R
Description
Indicates that hardware is still writing the 0x28A0
byte. Additional writes to this byte are locked out
while it is one. Write duration could be as long as 6 ms.
Sets the period between temperature measurements.
Automatic measurements can be enabled in any
mode (MSN, BRN, LCD, or SLP).
TEMP_PER[2:0]
28A0[2:0]
0
R/W
TEMP_PER
0
Time
Manual updates (see TEMP_START )
1-6
7
2 ^ (3+ TEMP_PER ) (seconds)
Continuous
TEMP_BAT
TEMP_START
TEMP_PWR
TEMP_BSEL
28A0[4]
28B4[6]
28A0[6]
28A0[7]
0
0
0
0
R/W
R/W
R/W
R/W
Causes VBAT to be measured whenever a
temperature measurement is performed.
TEMP_PER[2:0] must be zero in order for TEMP_START
to function. If TEMP_PER[2:0] = 0, then setting
TEMP_START starts a temperature measurement.
Ignored in SLP and LCD modes. Hardware clears
TEMP_START when the temperature measurement is
complete.
Selects the power source for the temperature sensor:
1 = V3P3D, 0 = VBAT_RTC. This bit is ignored in
SLP and LCD modes, where the temperature sensor is
always powered by VBAT_RTC.
Selects which battery is monitored by the
temperature sensor: 1 = VBAT, 0 = VBAT_RTC
TEMP_TEST[1:0] 2500[1:0]
0
R/W
Test bits for the temperature monitor VCO.
TEMP_TEST must be 00 in regular operation. Any
other value causes the VCO to run continuously with
the control voltage described below.
TEMP_TEST Function
00
01
1X
Normal operation
Reserved for factory test
Reserved for factory test
STEMP[10:3]
STEMP[2:0]
2881[7:0]
2882[7:5]
R
R
The result of the temperature measurement.
The STEMP[10:0] value may be obtained in C with a
single 16-bit read and divide by 32 operation as
follows:
volatile int16_t xdata STEMP _at_0x2881;
fa = (float)(STEMP/32);
BSENSE[7:0]
BCURR
2885[7:0]
2704[3]
0
0
R
R/W
The result of the battery measurement.
Connects a 100 μA load to the battery selected by
TEMP_BSEL .
v2
55
相关PDF资料
PDF描述
R1S-0524/HP CONV DC/DC 1W 05VIN 24VOUT
SS10P3CL-M3/87A DIODE SCHOTTKY 10A 30V SMPC
ISL6549CRZ IC REG DL BCK/LINEAR SYNC 16-QFN
ISL6549IRZ-T IC REG DL BCK/LINEAR SYNC 16-QFN
AMC40DRTF CONN EDGECARD 80POS .100 DIP SLD
相关代理商/技术参数
参数描述
71M6543FT-IGT/F 制造商:Maxim Integrated Products 功能描述:ENERGY METER ICS - Rail/Tube
71M6543FT-IGTR/F 制造商:Maxim Integrated Products 功能描述:3-PHASE SOC, 64KB FLASH, PRES TEMP SENSOR - Tape and Reel
71M6543G 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Selectable Gain of 1 or 8 for One Current Energy Meter ICs Metrology Compensation
71M6543GH 制造商:未知厂家 制造商全称:未知厂家 功能描述:电表IC
71M6543GHT-IGT/F 制造商:Maxim Integrated Products 功能描述:3-PHASE, 128KB, PRES TEMP SENSOR, HI PREC - Bulk