参数资料
型号: 71M6543F-IGTR/F
厂商: Maxim Integrated
文件页数: 127/154页
文件大小: 0K
描述: IC ENERGY METER 64K FLSH 100LQFP
标准包装: 1,000
系列: *
71M6543F/71M6543G Data Sheet
5.3.10 CE Calibration Parameters
Table 85 lists the parameters that are typically entered to effect calibration of meter accuracy.
Table 85: CE Calibration Parameters
= 16384. The gain of each
nominal value for each parameter is 2
more compensation (lag) is introduced. The range is ± 2 – 1. If it
0 . 029615 TAN Φ
CE
Address
0x10
0x11
0x13
0x14
0x16
0x17
0x19
0x12
0x15
Name
CAL_IA
CAL_VA
CAL_IB
CAL_VB
CAL_IC
CAL_VC
CAL_ID
PHADJ_A
PHADJ_B
Default
16384
16384
16384
16384
16384
16384
16384
0
0
Description
These constants control the gain of their respective channels. The
14
channel is directly proportional to its CAL parameter. Thus, if the
gain of a channel is 1% low, CAL should be increased by 1%.
These constants control the CT phase compensation. No
compensation occurs when PHADJ_X = 0. As PHADJ_X is increased,
15
is desired to delay the current by the angle Φ , the equations are:
PHADJ _ X = 2 20 at 60Hz
0 . 1714 ? 0 . 0168 ? TAN Φ
0x18
PHADJ_C
0
PHADJ _ X = 2 20
0 . 0206 ? TAN Φ
0 . 1430 ? 0 . 01226 ? TAN Φ
at 50Hz
The shunt delay compensation is obtained using the equation
provided below:
a 2 cos 2 ? ?
? ? + 2 ab cos ? ?
c sin ? ?
? ?
? ? + b
0x12
DLYADJ_A
0
DLYADJ _ X = ? deg rees ( 1 + 0 . 1 ? deg rees ) 2 14
2 π
360
? 2 π f ? ? 2 π f
? 2 π f ?
? f s ?
? f s ? ? f s
?
?
where:
a = 2 A
2 ????
0x15
DLYADJ_B
0
b = A 2 + 1
?? f ?? 2 + 4 ???????? ? ?? ? +2
?? = is 2 the mains frequency
f s is the sampling frequency
The table below provides the value of A for each channel:
0x18
DLYADJ_C
0
Channel
Value of A
(decimal)
D YADJ_A
DLYADJ_B
DLYADJ_C
13840
11693
9359
Note:
The current sensor inputs are not assigned to the A, B and C phases in a fixed manner. The
assignments of phases A, B and C depends on how the IADC0-1, IADC2-3, IADC4-5, IADC6-7 current
sensing inputs are connected in the meter design. The CE code must be aware of these connections.
See Figure 31 and Figure 32 for typical meter configurations. VADC8, VADC9 and VADC10 are
assigned to voltage phases VA, VB and VC in a fixed manner, respectively.
The CE addresses listed in this table are assigned to phases A, B and C as indicated by their names.
v2
127
相关PDF资料
PDF描述
R1S-0524/HP CONV DC/DC 1W 05VIN 24VOUT
SS10P3CL-M3/87A DIODE SCHOTTKY 10A 30V SMPC
ISL6549CRZ IC REG DL BCK/LINEAR SYNC 16-QFN
ISL6549IRZ-T IC REG DL BCK/LINEAR SYNC 16-QFN
AMC40DRTF CONN EDGECARD 80POS .100 DIP SLD
相关代理商/技术参数
参数描述
71M6543FT-IGT/F 制造商:Maxim Integrated Products 功能描述:ENERGY METER ICS - Rail/Tube
71M6543FT-IGTR/F 制造商:Maxim Integrated Products 功能描述:3-PHASE SOC, 64KB FLASH, PRES TEMP SENSOR - Tape and Reel
71M6543G 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Selectable Gain of 1 or 8 for One Current Energy Meter ICs Metrology Compensation
71M6543GH 制造商:未知厂家 制造商全称:未知厂家 功能描述:电表IC
71M6543GHT-IGT/F 制造商:Maxim Integrated Products 功能描述:3-PHASE, 128KB, PRES TEMP SENSOR, HI PREC - Bulk