参数资料
型号: AD7192BRUZ-REEL
厂商: Analog Devices Inc
文件页数: 11/41页
文件大小: 0K
描述: IC ADC 24BIT 2CH SD 24-TSSOP
设计资源: Precision Weigh Scale Design Using AD7192 with Internal PGA (CN0119)
标准包装: 2,500
位数: 24
采样率(每秒): 4.8k
数据接口: DSP,MICROWIRE?,QSPI?,串行,SPI?
转换器数目: 1
电压电源: 模拟和数字
工作温度: -40°C ~ 105°C
安装类型: 表面贴装
封装/外壳: 24-TSSOP(0.173",4.40mm 宽)
供应商设备封装: 24-TSSOP
包装: 带卷 (TR)
输入数目和类型: 2 个差分,单极;2 个差分,双极;4 个伪差分,单极;4 个伪差分,双极
AD7192
Rev. A | Page 18 of 40
ON-CHIP REGISTERS
The ADC is controlled and configured via a number of on-chip
registers that are described on the following pages. In the
following descriptions, “set” implies a Logic 1 state and
“cleared” implies a Logic 0 state, unless otherwise noted.
COMMUNICATIONS REGISTER
(RS2, RS1, RS0 = 0, 0, 0)
The communications register is an 8-bit write-only register. All
communications to the part must start with a write operation to
the communications register. The data written to the communi-
cations register determines whether the next operation is a read
or write operation and in which register this operation takes
place. For read or write operations, when the subsequent read
or write operation to the selected register is complete, the
interface returns to where it expects a write operation to the
communications register. This is the default state of the
interface and, on power-up or after a reset, the ADC is in this
default state waiting for a write operation to the communica-
tions register. In situations where the interface sequence is lost,
a write operation of at least 40 serial clock cycles with DIN high
returns the ADC to this default state by resetting the entire part.
Table 14 outlines the bit designations for the communications
register. CR0 through CR7 indicate the bit location, CR denoting
that the bits are in the communications register. CR7 denotes
the first bit of the data stream. The number in parentheses
indicates the power-on/reset default status of that bit.
CR7
CR6
CR5
CR4
CR3
CR2
CR1
CR0
WEN(0)
R/W(0)
RS2(0)
RS1(0)
RS0(0)
CREAD(0)
0(0)
Table 14. Communications Register Bit Designations
Bit Location
Bit Name
Description
CR7
WEN
Write enable bit. A 0 must be written to this bit so that the write to the communications register actually
occurs. If a 1 is the first bit written, the part does not clock on to subsequent bits in the register. It stays at
this bit location until a 0 is written to this bit. After a 0 is written to the WEN bit, the next seven bits are
loaded to the communications register. Idling the DIN pin high between data transfers minimizes the
effects of spurious SCLK pulses on the serial interface.
CR6
R/W
A 0 in this bit location indicates that the next operation is a write to a specified register. A 1 in this position
indicates that the next operation is a read from the designated register.
CR5 to CR3
RS2 to RS0
Register address bits. These address bits are used to select which registers of the ADC are selected during
the serial interface communication (see Table 15).
CR2
CREAD
Continuous read of the data register. When this bit is set to 1 (and the data register is selected), the serial
interface is configured so that the data register can be continuously read; that is, the contents of the data
register are automatically placed on the DOUT pin when the SCLK pulses are applied after the RDY pin
goes low to indicate that a conversion is complete. The communications register does not have to be
written to for subsequent data reads. To enable continuous read, the Instruction 01011100 must be written
to the communications register. To disable continuous read, the Instruction 01011000 must be written to
the communications register while the RDY pin is low. While continuous read is enabled, the ADC monitors
activity on the DIN line so that it can receive the instruction to disable continuous read. Additionally, a reset
occurs if 40 consecutive 1s are seen on DIN. Therefore, DIN should be held low until an instruction is to be
written to the device.
CR1 to CR0
0
These bits must be programmed to Logic 0 for correct operation.
Table 15. Register Selection
RS2
RS1
RS0
Register
Register Size
0
Communications register during a write operation
8 bits
0
Status register during a read operation
8 bits
0
1
Mode register
24 bits
0
1
0
Configuration register
24 bits
0
1
Data register/data register plus status information
24 bits/32 bits
1
0
ID register
8 bits
1
0
1
GPOCON register
8 bits
1
0
Offset register
24 bits
1
Full-scale register
24 bits
相关PDF资料
PDF描述
MS27656T25F24SLC CONN HSG RCPT 24POS WALL MT SCKT
D38999/26JG39PNLC CONN HSG PLUG 39POS STRGHT PINS
AD7783BRU-REEL7 IC ADC 24BIT 2CH R-R 16-TSSOP
D38999/26WE6PALC CONN HSG PLUG 6POS STRGHT PINS
VI-B2H-MY CONVERTER MOD DC/DC 52V 50W
相关代理商/技术参数
参数描述
AD7193 制造商:AD 制造商全称:Analog Devices 功能描述:4-Channel, 4.8 kHz, Ultralow Noise, 24-Bit Sigma-Delta ADC with PGA
AD7193BCPZ 功能描述:IC ADC 24BIT SPI 4.8KHZ 32LFCSP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1,000 系列:- 位数:12 采样率(每秒):300k 数据接口:并联 转换器数目:1 功率耗散(最大):75mW 电压电源:单电源 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:24-SOIC(0.295",7.50mm 宽) 供应商设备封装:24-SOIC 包装:带卷 (TR) 输入数目和类型:1 个单端,单极;1 个单端,双极
AD7193BCPZ-RL 功能描述:IC ADC 24BIT SPI 4.8KHZ 32LFCSP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1,000 系列:- 位数:16 采样率(每秒):45k 数据接口:串行 转换器数目:2 功率耗散(最大):315mW 电压电源:模拟和数字 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:28-SOIC(0.295",7.50mm 宽) 供应商设备封装:28-SOIC W 包装:带卷 (TR) 输入数目和类型:2 个单端,单极
AD7193BCPZ-RL7 功能描述:IC ADC 24BIT SPI 4.8KHZ 32LFCSP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1,000 系列:- 位数:16 采样率(每秒):45k 数据接口:串行 转换器数目:2 功率耗散(最大):315mW 电压电源:模拟和数字 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:28-SOIC(0.295",7.50mm 宽) 供应商设备封装:28-SOIC W 包装:带卷 (TR) 输入数目和类型:2 个单端,单极
AD7193BRUZ 功能描述:IC ADC 24BIT SPI 4.8K 28-TSSOP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1 系列:microPOWER™ 位数:8 采样率(每秒):1M 数据接口:串行,SPI? 转换器数目:1 功率耗散(最大):- 电压电源:模拟和数字 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:24-VFQFN 裸露焊盘 供应商设备封装:24-VQFN 裸露焊盘(4x4) 包装:Digi-Reel® 输入数目和类型:8 个单端,单极 产品目录页面:892 (CN2011-ZH PDF) 其它名称:296-25851-6