参数资料
型号: CRD5463PM-Z
厂商: Cirrus Logic Inc
文件页数: 23/46页
文件大小: 0K
描述: REFERENCE DESIGN FOR POWER METER
标准包装: 1
主要目的: 电源管理,电度表/功率表
嵌入式: 是,MCU,8 位
已用 IC / 零件: CS5463
主要属性: 单相功率表
次要属性: 90 ~ 260 VAC
已供物品: 模块,适配器,线缆,电源线
其它名称: 598-1943
CS5463
5.16 Commands
All commands are 8 bits in length. Any command byte value that is not listed in this section is invalid. Commands
that write to registers must be followed by 3 bytes of data. Commands that read data can be chained with other com-
mands (e.g., while reading data, a new command can be sent which can execute during the original read). All com-
mands except register reads, register writes, and SYNC0 & SYNC1 will abort any currently executing commands.
5.16.1 Start Conversions
B7
1
B6
1
B5
1
B4
0
B3
C3
B2
0
B1
0
B0
0
Initiates acquiring measurements and calculating results. The device has two modes of acquisition.
C3
Modes of acquisition/measurement
0 = Perform a single computation cycle
1 = Perform continuous computation cycles
5.16.2 SYNC0 and SYNC1
B7
1
B6
1
B5
1
B4
1
B3
1
B2
1
B1
1
B0
SYNC
The serial port can be initialized by asserting CS or by sending three or more consecutive SYNC1 commands fol-
lowed by a SYNC0 command. The SYNC0 or SYNC1 can also be sent while sending data out.
SYNC
0 = Last byte of a serial port re-initialization sequence.
1 = Used during reads and serial port initialization.
5.16.3 Power-up/Halt
B7
1
B6
0
B5
1
B4
0
B3
0
B2
0
B1
0
B0
0
If the device is powered-down, Power-Up/Halt will initiate a power on reset. If the part is already powered-on, all
computations will be halted.
5.16.4 Power-down and Software Reset
B7
1
B6
0
B5
0
B4
S1
B3
S0
B2
0
B1
0
B0
0
To conserve power the CS5463 has two power-down states. In stand-by state all circuitry, except the analog/digital
clock generators, is turned off. In the sleep state all circuitry, except the command decoder, is turned off. Bringing
the CS5463 out of sleep state requires more time than out of stand-by state, because of the extra time needed to
re-start and re-stabilize the analog oscillator.
S[1:0]
DS678F3
Power-down state
00 = Software Reset
01 = Halt and enter stand-by power saving state. This state allows quick power-on
10 = Halt and enter sleep power saving state.
11 = Reserved
23
相关PDF资料
PDF描述
M1AXA-1436R IDC CABLE - MSC14A/MC14M/X
0982660228 CBL 22POS .5MM JMPR TYPE D 1.18"
301A034-4-0 BOOT MOLDED
H3DDS-1418M IDC CABLE - HKR14S/AE14M/HKR14S
0982660227 CBL 22POS .5MM JMPR TYPE A 1.18"
相关代理商/技术参数
参数描述
CRD5490-Z 功能描述:电源管理IC开发工具 CS5463 Pwr Meas/Mntr Reference Design RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
CRD5AS-12B 制造商:RENESAS 制造商全称:Renesas Technology Corp 功能描述:Reverse Conducting Thyristor Medium Power Use
CRD5AS-12B#B00 功能描述:SCR 600V 7.8A Sensitive Gate Surface Mount MP-3A 制造商:renesas electronics america 系列:- 包装:管件 零件状态:有效 电压 - 断态:600V 电压 - 栅极触发(Vgt)(最大值):800mV 电流 - 栅极触发(Igt)(最大值):100μA 电压 - 通态(Vtm)(最大值):1.8V 电流 - 通态(It(AV))(最大值):5A 电流 - 通态(It(RMS))(最大值):7.8A 电流 - 保持(Ih)(最大值):3mA 电流 - 断态(最大值):2mA 电流 - 不重复浪涌 50,60Hz(Itsm):90A @ 60Hz SCR 类型:灵敏栅极 工作温度:-40°C ~ 150°C 安装类型:表面贴装 封装/外壳:TO-252-3,DPak(2 引线+接片),SC-63 供应商器件封装:MP-3A 标准包装:1
CRD5AS-12BB00 制造商:RENESAS 制造商全称:Renesas Technology Corp 功能描述:Reverse Conducting Thyristor Medium Power Use
CRD5AS-12B-T13B00 制造商:RENESAS 制造商全称:Renesas Technology Corp 功能描述:Reverse Conducting Thyristor Medium Power Use