However, an AC signal cannot be used for DC gain cal-
ibration.
7.1.3.2 DC Gain Calibration Sequence
Initiate a DC gain calibration. The corresponding gain
register is restored to default (1.0). The DC gain calibra-
tion averages the channel’s instantaneous measure-
ments over one computation cycle (N samples). The
average is then divided into 1.0 and the quotient is
stored in the corresponding gain register
After the DC gain calibration, the instantaneous register
will read at full-scale whenever the DC level of the input
signal is equal to the level of the DC calibration signal
applied to the inputs during the DC gain calibration.The
HPF option should not be enabled if DC gain calibration
is utilized.
7.1.4 Order of Calibration Sequences
1. If the HPF option is enabled, then any DC component
that may be present in the selected signal path will be
removed and a DC offset calibration is not required.
However, if the HPF option is disabled the DC offset
calibration sequence should be performed.
When using high-pass filters, it is recommended that
the DC Offset register for the corresponding channel
be set to zero. When performing DC offset calibra-
culated in step 2 by the gain calculated in step 3 and
updating the AC offset register with the product.
7.2 Phase Compensation
The CS5463 is equipped with phase compensation to
cancel out phase shifts introduced by the measurement
element. Phase Compensation is set by bits PC[6:0] in
the Configuration Register and bits XVDEL and XIDEL
in the Operational Mode Register
The default value of PC[6:0], XVDEL, and XIDEL is ze-
ro. With MCLK = 4.096 MHz and K = 1, the phase com-
pensation has a range of ? 8.1 degrees when the input
signals are 60 Hz. Under these conditions, each step of
the phase compensation register (value of one LSB) is
approximately 0.04 degrees. For values of MCLK other
than 4.096 MHz, the range and step size should be
scaled by 4.096 MHz/(MCLK/K). For power line fre-
quencies other than 60Hz, the values of the range and
step size of the PC[6:0] bits can be determined by con-
verting the above values from angular measurement
into the time domain (seconds), and then computing the
new range and step size (in degrees) with respect to the
new line frequency. To calculate the phase shift induced
between the voltage and the current channel use the
equation:
Freq ? 360 ? ? PC ? 5:0 ? – ? PC ? 6 ? ? 64 ? + ? XDEL ? 128 ? ?
? MCLK ? K ? ? 8
tion, the corresponding gain channel should be set to
one.
2. If there is an AC offset in the V RMS or I RMS calcula-
Phase
o
= ---------------------------------------------------------------------------------------------------------------------------------
tion, then the AC offset calibration sequence should
be performed.
3. Perform the gain calibration sequence.
4. Finally, if an AC offset calibration was performed
(step 2), then the AC offset may need to be adjusted
to compensate for the change in gain (step 3). This
can be accomplished by restoring zero to the AC off-
set register and then perform an AC offset calibration
sequence. The adjustment could also be done by
multiplying the AC offset register value that was cal-
DS678F3
Freq = Line Frequency [Hz]
XDEL = XVDEL or -XIDEL
7.3 Active Power Offset
The Power Offset Register can be used to offset system
power sources that may be resident in the system, but
do not originate from the power line signal. These sourc-
es of extra energy in the system contribute undesirable
and false offsets to the power and energy measurement
results. After determining the amount of stray power, the
Power Offset Register can be set to cancel the effects
of this unwanted energy.
39
相关PDF资料
PDF描述
M1AXA-1436R IDC CABLE - MSC14A/MC14M/X
0982660228 CBL 22POS .5MM JMPR TYPE D 1.18"
301A034-4-0 BOOT MOLDED
H3DDS-1418M IDC CABLE - HKR14S/AE14M/HKR14S
0982660227 CBL 22POS .5MM JMPR TYPE A 1.18"
相关代理商/技术参数
参数描述
CRD5490-Z 功能描述:电源管理IC开发工具 CS5463 Pwr Meas/Mntr Reference Design RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
CRD5AS-12B 制造商:RENESAS 制造商全称:Renesas Technology Corp 功能描述:Reverse Conducting Thyristor Medium Power Use
CRD5AS-12B#B00 功能描述:SCR 600V 7.8A Sensitive Gate Surface Mount MP-3A 制造商:renesas electronics america 系列:- 包装:管件 零件状态:有效 电压 - 断态:600V 电压 - 栅极触发(Vgt)(最大值):800mV 电流 - 栅极触发(Igt)(最大值):100μA 电压 - 通态(Vtm)(最大值):1.8V 电流 - 通态(It(AV))(最大值):5A 电流 - 通态(It(RMS))(最大值):7.8A 电流 - 保持(Ih)(最大值):3mA 电流 - 断态(最大值):2mA 电流 - 不重复浪涌 50,60Hz(Itsm):90A @ 60Hz SCR 类型:灵敏栅极 工作温度:-40°C ~ 150°C 安装类型:表面贴装 封装/外壳:TO-252-3,DPak(2 引线+接片),SC-63 供应商器件封装:MP-3A 标准包装:1
CRD5AS-12BB00 制造商:RENESAS 制造商全称:Renesas Technology Corp 功能描述:Reverse Conducting Thyristor Medium Power Use
CRD5AS-12B-T13B00 制造商:RENESAS 制造商全称:Renesas Technology Corp 功能描述:Reverse Conducting Thyristor Medium Power Use