4.12 Configuration Scripts and Log File
4.12.1 Configuration Log File
Every write command issued by the software to the DS3106DK board is logged in file DS3106DKLog.mfg located
in the same directory as the software executable. This file can be viewed in Notepad by pressing the Log File
button in the upper-right corner of the main window. Command line option "-l <filepath>" can be used to cause the
software to write to a file other than DS3106DKLog.mfg.
4.12.2 Configuration Scripts
All or part of the text in the configuration log file can be copied to a text file with a .mfg file extension for use as a
configuration script. Configuration scripts are useful for quickly configuring the DS3106 without having to remember
all the required settings.
Two types of configuration scripts are possible: full and partial. A full configuration script can start with the DS3106
in its power-on default state and configure every aspect of the device to bring it to a desired state. To make a full
configuration script, run the software, uncheck the Demo Mode checkbox, initialize the device, configure the device
using the DK software fields, press the Log File button, and use File → Save As in Notepad to save a copy of the
entire log file to a different file name.
A partial configuration file only affects a subset of the DS3106 device settings. To make a partial configuration
script, press the Log File button to view the log file, press Ctrl-End to jump to the end of the file, and add to the
end of the file a carriage return or comment line (starting with a semicolon) to delimit the start of the desired
configuration. Then save and exit the log file. Next, configure the device using the DK software fields. Finally, view
the log file again, jump to the end, and copy everything from the delimiter to the end of the file into a new .mfg file.
To run a configuration script, press the Config Script button in the upper-right corner of the main window. In the
script window, type the path to the file or press the Browse button to navigate to the file.
Note that when the Demo Mode checkbox is unchecked, during the Initializing the DS3106 step, the software
runs configuration script startup.mfg located in the same directory as the software executable. The startup.mfg file
can be edited or replaced as needed to change the initial configuration of the device. Be aware, however, that the
section of the startup.mfg file labeled Required Initialization must be executed after device power-up or reset for
the DS3106 to operate correctly.
Rev: 012208
16 of 32
相关PDF资料
PDF描述
DS3144DK KIT DEMO FOR DS3144
DS3150DK KIT DEMO DS3150 DS3/E3/STS-2 LIU
DS3153DK KIT DEMO FOR DS3153
DS3154DK KIT DEMO FOR DS3154
DS3170DK KIT DESIGN FOR DS3170
相关代理商/技术参数
参数描述
DS3106E12S-3S(621) 制造商:Amphenol Corporation 功能描述:
DS3106F-10SL-3S 制造商:Amphenol Corporation 功能描述:
DS3106F-10SL-4P 制造商:Amphenol Corporation 功能描述:
DS3106F-10SL-4S 制造商:Amphenol 功能描述:10SL-4 vO Solder 500VDC / 700VAC 13A 125 Silver 制造商:Amphenol 功能描述:10SL-4 vO Solder 500VDC / 700VAC 13A 125 Silver Bulk
DS3106F-10SL-4S(621) 制造商:Amphenol Corporation 功能描述: