June 20, 2012
Functional Description
Power Control Operation
The power control circuit accepts a VDD and a VBAT input. Many
types of batteries can be used with Intersil RTC products. For
example, 3.0V or 3.6V Lithium batteries are appropriate, and battery
sizes are available that can power the ISL12022M for up to 10
years. Another option is to use a supercapacitor for applications
where VDD is interrupted for up to a month. See the “Application
Section” on page 26 for more information.
Normal Mode (VDD) to Battery Backup Mode
(VBAT)
To transition from the VDD to VBAT mode, both of the following
conditions must be met:
Condition 1:
VDD < VBAT - VBATHYS
where VBATHYS ≈ 50mV
Condition 2:
VDD < VTRIP
where VTRIP ≈ 2.2V
Battery Backup Mode (VBAT) to Normal Mode
(VDD)
The ISL12022M device will switch from the VBAT to VDD mode
when one of the following conditions occurs:
Condition 1:
VDD > VBAT + VBATHYS
where VBATHYS ≈ 50mV
Condition 2:
VDD > VTRIP + VTRIPHYS
where VTRIPHYS ≈ 30mV
These power control situations are illustrated in Figures 14 and 15.
The I2C bus is deactivated in battery backup mode to reduce
power consumption. Aside from this, all RTC functions are
operational during battery backup mode. Except for SCL and SDA,
all the inputs and outputs of the ISL12022M are active during
battery backup mode unless disabled via the control register.
The device Time Stamps the switchover from VDD to VBAT and
VBAT to VDD, and the time is stored in tSV2B and tSB2V registers
respectively. If multiple VDD power-down sequences occur before
the status is read, the earliest VDD to VBAT power-down time is
stored and the most recent VBAT to VDD time is stored.
Temperature conversion and compensation can be enabled in
battery backup mode. Bit BTSE in the BETA register controls this
operation, as described in “BETA Register (BETA)” on page 18.
Power Failure Detection
The ISL12022M provides a Real Time Clock Failure Bit (RTCF) to
detect total power failure. It allows users to determine if the
device has powered up after having lost all power to the device
(both VDD and VBAT).
Brownout Detection
The ISL12022M monitors the VDD level continuously and
provides warning if the VDD level drops below prescribed levels.
There are six (6) levels that can be selected for the trip level.
These values are 85% below popular VDD levels. The LVDD bit in
the Status Register will be set to “1” when brownout is detected.
Note that the I2C serial bus remains active unless the Battery
VTRIP levels are reached.
Battery Level Monitor
The ISL12022M has a built-in warning feature once the backup
battery level drops first to 85% and then to 75% of the battery’s
nominal VBAT level. When the battery voltage drops to between
85% and 75%, the LBAT85 bit is set in the status register. When
the level drops below 75%, both LBAT85 and LBAT75 bits are set
in the status register.
The battery level monitor is not functional in battery backup
mode. In order to read the monitor bits after powering up VDD,
instigate a battery level measurement by setting the TSE bit to
"1" (BETA register), and then read the bits.
There is a Battery Time Stamp Function available. Once the VDD is
low enough to enable switchover to the battery, the RTC time/date
are written into the TSV2B register. This information can be read
from the TSV2B registers to discover the point in time of the VDD
power-down. If there are multiple power-down cycles before
reading these registers, the first values stored in these registers
will be retained. These registers will hold the original power-down
value until they are cleared by setting CLRTS = 1 to clear the
registers.
The normal power switching of the ISL12022M is designed to
switch into battery backup mode only if the VDD power is lost.
VBAT - VBATHYS
VBAT
VBAT + VBATHYS
BATTERY BACKUP
MODE
VDD
VTRIP
2.2V
1.8V
FIGURE 14. BATTERY SWITCHOVER WHEN VBAT <VTRIP
FIGURE 15. BATTERY SWITCHOVER WHEN VBAT > VTRIP
VTRIP
VBAT
VTRIP + VTRIPHYS
BATTERY BACKUP
MODE
VDD
VTRIP
3.0V
2.2V
相关PDF资料
PDF描述
UCY2G470MHD3TN CAP ALUM 47UF 400V 20% RADIAL
RMM11DSXH CONN EDGECARD 22POS DIP .156 SLD
EBM30DRSS CONN EDGECARD 60POS DIP .156 SLD
ECO-S1EA183CA CAP ALUM 18000UF 25V 20% SNAP
RMM11DRXN CONN EDGECARD 22POS DIP .156 SLD
相关代理商/技术参数
参数描述
ISL12022MIBZR5421 功能描述:实时时钟 REAL TIME CLK W/MFK IMPROVED ESD AIR RoHS:否 制造商:Microchip Technology 功能:Clock, Calendar. Alarm RTC 总线接口:I2C 日期格式:DW:DM:M:Y 时间格式:HH:MM:SS RTC 存储容量:64 B 电源电压-最大:5.5 V 电源电压-最小:1.8 V 最大工作温度:+ 85 C 最小工作温度: 安装风格:Through Hole 封装 / 箱体:PDIP-8 封装:Tube
ISL12022MIBZ-T 功能描述:实时时钟 REAL TIME CLK & TEMP COMPENSATED CRYSTAL RoHS:否 制造商:Microchip Technology 功能:Clock, Calendar. Alarm RTC 总线接口:I2C 日期格式:DW:DM:M:Y 时间格式:HH:MM:SS RTC 存储容量:64 B 电源电压-最大:5.5 V 电源电压-最小:1.8 V 最大工作温度:+ 85 C 最小工作温度: 安装风格:Through Hole 封装 / 箱体:PDIP-8 封装:Tube
ISL12022MIBZ-T7A 功能描述:IC RTC/CALENDAR TEMP SNSR 20SOIC RoHS:否 类别:集成电路 (IC) >> 时钟/计时 - 实时时钟 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- 类型:时钟/日历 特点:警报器,闰年,SRAM 存储容量:- 时间格式:HH:MM:SS(12/24 小时) 数据格式:YY-MM-DD-dd 接口:SPI 电源电压:2 V ~ 5.5 V 电压 - 电源,电池:- 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:8-WDFN 裸露焊盘 供应商设备封装:8-TDFN EP 包装:管件
ISL12022MIBZ-TR5421 功能描述:实时时钟 REAL TIME CLK W/MFK IMPROVED ESD AIR RoHS:否 制造商:Microchip Technology 功能:Clock, Calendar. Alarm RTC 总线接口:I2C 日期格式:DW:DM:M:Y 时间格式:HH:MM:SS RTC 存储容量:64 B 电源电压-最大:5.5 V 电源电压-最小:1.8 V 最大工作温度:+ 85 C 最小工作温度: 安装风格:Through Hole 封装 / 箱体:PDIP-8 封装:Tube
ISL12022MR5421 制造商:INTERSIL 制造商全称:Intersil Corporation 功能描述:Low Power RTC with Battery Backed SRAM, Integrated 5ppm