参数资料
型号: ISL6324ACRZ
厂商: Intersil
文件页数: 24/40页
文件大小: 0K
描述: IC HYBRID CTRLR PWM DUAL 48QFN
标准包装: 43
应用: 控制器,AMD SVI
输入电压: 5 V ~ 12 V
输出数: 2
输出电压: 最高 2V
工作温度: 0°C ~ 70°C
安装类型: 表面贴装
封装/外壳: 48-VFQFN 裸露焊盘
供应商设备封装: 48-QFN(7x7)
包装: 管件
ISL6324A
I OCP = 100 μ A ? ? ? ? ---------- ? R SET ? – ---------------------------------------- ? ----------------
N 1 3 V IN – N ? V OUT V OUT
DCR K ? 400
?
2 ? L ? f S
page 15 for more detail on how the average current is
measured. Once the average current exceeds 100μA, a
comparator triggers the converter to begin overcurrent
protection procedures. The Core regulator and the North
Bridge regulator have the same type of overcurrent
protection.
The overcurrent trip threshold is dictated by the DCR of the
inductors, the number of active channels, the DC gain of the
inductor RC filter and the R SET resistor. The overcurrent trip
threshold is shown in Equation 18.
------------- ----
V IN
(EQ. 18)
Where:
zero. Once the regulator has completed soft-start, the
overcurrent trip point will return to it’s nominal setting and an
overcurrent shutdown will be initiated. This will result in a
continuous hiccup mode.
Note that the energy delivered during trip-retry cycling is
much less than during full-load operation, so there is no
thermal hazard.
OUTPUT CURRENT, 50A/DIV
0A
R 2
K = ---------------------
R 1 + R 2
OUTPUT VOLTAGE,
500mV/DIV
f S = Switching Frequency
0V
Equation 18 is valid for both the Core regulator and the
North Bridge regulator. This equation includes the DC load
current as well as the total ripple current contributed by all
the phases. For the North Bridge regulator, N is 1.
During soft-start, the overcurrent trip point is boosted by a
factor of 1.4. Instead of comparing the average measured
current to 100μA, the average current is compared to 140μA.
Immediately after soft-start is over, the comparison level
changes to 100μA. This is done to allow for start-up into an
active load while still supplying output capacitor in-rush
current.
CORE REGULATOR OVERCURRENT
At the beginning of overcurrent shutdown, the controller sets
all of the UGATE and LGATE signals low, puts PWM3 and
PWM4 (if active) in a high-impedance state, and forces
VDDPWRGD low. This turns off all of the upper and lower
MOSFETs. The system remains in this state for fixed period of
12ms. If the controller is still enabled at the end of this wait
period, it will attempt a soft-start, as shown in Figure 14. If the
fault remains, the trip-retry cycles will continue until either the
fault is cleared or for a total of seven attempts. If the fault is
not cleared on the final attempt, the controller disables
UGATE and LGATE signals for both Core and North Bridge
and latches off requiring a POR of VCC to reset the
ISL6324A.
It is important to note that during soft start, the overcurrent
trip point is increased by a factor of 1.4. If the fault draws
enough current to trip overcurrent during normal run mode, it
may not draw enough current during the soft-start ramp
period to trip overcurrent while the output is ramping up. If a
fault of this type is affecting the output, then the regulator will
complete soft-start and the trip-retry counter will be reset to
24
3ms/DIV
FIGURE 14. OVERCURRENT BEHAVIOR IN HICCUP MODE
NORTH BRIDGE REGULATOR OVERCURRENT
The overcurrent shutdown sequence for the North Bridge
regulator is identical to the Core regulator with the exception
that it is a single phase regulator and will only disable the
MOSFET drivers for the North Bridge. Once 7 retry attempts
have been executed unsuccessfully, the controller will disable
UGATE and LGATE signals for both Core and North Bridge
and will latch off requiring a POR of VCC to reset the
ISL6324A.
Note that the energy delivered during trip-retry cycling is
much less than during full-load operation, so there is no
thermal hazard.
Individual Channel Overcurrent Limiting
The ISL6324A has the ability to limit the current in each
individual channel of the Core regulator without shutting
down the entire regulator. This is accomplished by
continuously comparing the sensed currents of each channel
with a constant 140μA OCL reference current. If a channel’s
individual sensed current exceeds this OCL limit, the UGATE
signal of that channel is immediately forced low, and the
LGATE signal is forced high. This turns off the upper
MOSFET(s), turns on the lower MOSFET(s), and stops the
rise of current in that channel, forcing the current in the
channel to decrease. That channel’s UGATE signal will not
be able to return high until the sensed channel current falls
back below the 140μA reference.
I 2 C Bus Interface
The ISL6324A includes an I 2 C bus interface which allows for
user programmability of three of the controller ’s operating
FN6880.2
May 14, 2010
相关PDF资料
PDF描述
1782-83J COIL RF 430UH MOLDED UNSHIELDED
LT1529CT-5#PBF IC REG LDO 5V 3A TO220
2150-20K COIL RF 6.8UH MOLDED UNSHIELDED
2150-18K COIL RF 5.6UH MOLDED UNSHIELDED
LT1529CT#PBF IC REG LDO ADJ 3A TO220
相关代理商/技术参数
参数描述
ISL6324ACRZR5381 制造商:Intersil Corporation 功能描述:4+1 PHASE CONTROLLER, CORE+NORTHBRIDGE, PROG PSI, 3.4MHZ SVI - Rail/Tube 制造商:Intersil Corporation 功能描述:IC HYBRID CTRLR PWM DUAL 48QFN
ISL6324ACRZ-T 功能描述:IC HYBRID CTRLR PWM DUAL 48QFN RoHS:是 类别:集成电路 (IC) >> PMIC - 稳压器 - 专用型 系列:- 标准包装:43 系列:- 应用:控制器,Intel VR11 输入电压:5 V ~ 12 V 输出数:1 输出电压:0.5 V ~ 1.6 V 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:48-VFQFN 裸露焊盘 供应商设备封装:48-QFN(7x7) 包装:管件
ISL6324ACRZ-TR5381 制造商:Intersil Corporation 功能描述:4+1 PHASE CONT., CORE + NORTHBRIDGE, PROG PSI, 3.4MHZ SVI, 5 - Tape and Reel 制造商:Intersil Corporation 功能描述:IC HYBRID CTRLR PWM DUAL 48QFN
ISL6324AIRZ 功能描述:IC HYBRID CTRLR PWM DUAL 48QFN RoHS:是 类别:集成电路 (IC) >> PMIC - 稳压器 - 专用型 系列:- 标准包装:43 系列:- 应用:控制器,Intel VR11 输入电压:5 V ~ 12 V 输出数:1 输出电压:0.5 V ~ 1.6 V 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:48-VFQFN 裸露焊盘 供应商设备封装:48-QFN(7x7) 包装:管件
ISL6324AIRZR5381 制造商:Intersil Corporation 功能描述:4+1 PHASE CONTROLLER, CORE + NORTHBRIDGE, PROG PSI, 3.4MHZ S - Rail/Tube 制造商:Intersil Corporation 功能描述:IC HYBRID CTRLR PWM DUAL 48QFN