参数资料
型号: XBIB-R
厂商: Digi International/Maxstream
文件页数: 14/72页
文件大小: 1116K
描述: BOARD RS232 ZIGBEE MOD PRO
设计资源: XBIB-R Schematic
标准包装: 1
附件类型: 接口板
适用于相关产品: XBee 和 XBee Pro 收音机
XBee/XBeePRO"燨EM燫F燤odules??02.15.4?爒1.xAx燵2007.05.031]
2007燤axStream,營nc.
牋牋?4
Chapter??燫F燤odule燨peration
2.2.6. I/O Line Passing
Virtual wires can be set up between XBee/XBee-PRO Modules. When an RF data packet is received
that contains I/O data, the receiving module can be setup to update any enabled outputs (PWM
and DIO) based on the data it receives.
Note that I/O lines are mapped in pairs. For example: AD0 can only update PWM0 and DI5 can
only update DO5). The default setup is for outputs not to be updated, which results in the I/O data
being sent out the UART (refer to the IU (Enable I/O Output) command). To enable the outputs to
be updated, the IA (I/O Input Address) parameter must be setup with the address of the module
that has the appropriate inputs enabled. This effectively binds the outputs to a particular modules
input. This does not affect the ability of the module to receive I/O line data from other modules -
only its ability to update enabled outputs. The IA parameter can also be setup to accept I/O data
for output changes from any module by setting the IA parameter to 0xFFFF.
When outputs are changed from their non-active state, the module can be setup to return the out-
put level to it non-active state. The timers are set using the Tn (Dn Output Timer) and PT (PWM
Output Timeout) commands. The timers are reset every time a valid I/O packet (passed IA check)
is received. The IC (Change Detect) and IR (Sample Rate) parameters can be setup to keep the
output set to their active output if the system needs more time than the timers can handle.
Note: DI8 can not be used for I/O line passing.
Applicable Commands: IA (I/O Input Address), Tn (Dn Output Timeout), P0 (PWM0 Configura-
tion), P1 (PWM1 Configuration), M0 (PWM0 Output Level), M1 (PWM1 Output Level), PT (PWM
Output Timeout), RP (RSSSI PWM Timer)
2.2.7. Configuration Example
As an example for a simple A/D link, a pair of RF modules could be set as follows:
These settings configure the remote module to sample AD0 and AD1 once each every 20 ms. It
then buffers 5 samples each before sending them back to the base module. The base should then
receive a 32-Byte transmission (20 Bytes data and 12 Bytes framing) every 100 ms.
Remote Configuration
DL = 0x1234
MY = 0x5678
D0 = 2
D1 = 2
IR = 0x14
IT = 5
Base Configuration
DL = 0x5678
MY = 0x1234
P0 = 2
P1 = 2
IU = 1
IA = 0x5678 (or 0xFFFF)
相关PDF资料
PDF描述
XPGWHT-01-0000-00FD4 XLAMP XPG LED COMM WARM/NTRL WHT
OPB480T11Z SWITCH PHOTOLOGIC SLOTTD OPTICAL
XPERDO-L1-0000-00A03 XLAMP XP-E LED - RED-ORANGE
XPEHEW-L1-0000-00H50 LED XLAMP XPE HIEFF WHITE SMD
OPB480P11Z SWITCH PHOTOLOGIC SLOTTD OPTICAL
相关代理商/技术参数
参数描述
XBIB-R-DEV 功能描述:界面开发工具 RS-232 XBee-PRO pro onal interface board RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V
XBIB-U 功能描述:界面开发工具 USB XBee-PRO interf -PRO interface board RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V
XBIB-U-DEV 功能描述:界面开发工具 USB XBee-PRO profes onal interface board RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V
XBIB-U-SP 功能描述:界面开发工具 USB/Xbee/Xbee-Pro Inf Brd SMT Pads RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V
XBIB-U-SS 功能描述:界面开发工具 USB/Xbee/Xbee-Pro Inf Brd SMT Skt RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V