参数资料
型号: ADE7953ACPZ
厂商: Analog Devices Inc
文件页数: 32/72页
文件大小: 0K
描述: IC ENERGY METERING 1PH 28LFCSP
标准包装: 1
输入阻抗: 660 千欧
测量误差: 0.1%
电压 - 高输入/输出: 2.4V
电压 - 低输入/输出: 0.4V
电流 - 电源: 6.8mA
电源电压: 3 V ~ 3.6 V
测量仪表类型: 单相
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 28-WFQFN 裸露焊盘,CSP
供应商设备封装: 28-LFCSP-WQ(5x5)
包装: 托盘
ADE7953
xVAGAIN
xVAOS
Data Sheet
APPARENT
POWER
SIGNAL
+
+
48 0
INTERNAL
ACCUMULATION
FIXED INTERNAL
THRESHOLD
OUTPUT FROM
VOLTAGE CHANNEL
ADC
LPF1
ZERO-CROSSING
DETECTION
CALIBRATION
CONTROL
23
APENERGYx
0
15
LINECYC
0
Figure 56. Apparent Energy Line Cycle Accumulation
Apparent Energy Line Cycle Accumulation Mode
In apparent energy line cycle accumulation mode, the energy
accumulation of the ADE7953 is synchronized to the voltage
channel zero crossing so that the apparent energy on Current
Channel A and Current Channel B can be accumulated over
an integral number of half line cycles. Line cycle accumulation
mode is disabled by default and can be enabled on Current
Channel A and Current Channel B by setting the ALVA and
BLVA bits to 1 in the LCYCMODE register (Address 0x004).
The accumulation time should be written to the LINECYC
register (Address 0x101) in the unit of number of half line cycles.
The number of half line cycles written to the LINECYC register
is used for both the Current Channel A and Current Channel B
accumulation periods. The ADE7953 can accumulate apparent
energy for up to 65,535 half line cycles. This equates to an accu-
mulation period of approximately 655 sec with 50 Hz inputs
and 546 sec with 60 Hz inputs.
At the end of a line cycle accumulation cycle, the APENERGYA
and APENERGYB registers are updated, and the CYCEND flag
in the IRQSTATA register (Address 0x22D and Address 0x32D)
is set. If the CYCEND bit in the IRQENA register is set, an external
interrupt is issued on the IRQ pin. In this way, the IRQ pin can
also be used to signal the completion of the line cycle accumula-
tion. Another accumulation cycle begins immediately, as long as
the ALVA and BLVA bits in the LCYCMODE register remain set.
The contents of the APENERGYA and APENERGYB registers
are updated synchronous to the CYCEND flag. The APENERGYA
and APENERGYB registers hold their current values until the
end of the next line cycle period, when the contents are replaced
with the new reading. If the read-with-reset bit (RSTREAD) in
If a new value is written to the LINECYC register (Address 0x101)
midway through a line cycle accumulation, the new value is not
internally loaded until the end of a line cycle period. When the
LINECYC register is updated mid-reading, the current energy
accumulation cycle is completed, and the new value is then
programmed, ready for the next cycle. This prevents any invalid
readings due to changes to the LINECYC register (see Figure 47).
Note that when line cycle accumulation mode is first enabled, the
reading after the first CYCEND flag should be ignored because
it may be inaccurate. This is because the line cycle accumulation
mode is not synchronized to the zero crossing and, therefore,
the first reading may not be over a complete number of half line
cycles. After the first line cycle accumulation is complete, all
successive readings will be correct.
AMPERE-HOUR ACCUMULATION
In a tampering situation where no voltage is available to the energy
meter, the ADE7953 can accumulate the ampere-hour measure-
ment instead of the apparent power in the APENERGYA and
APENERGYB registers. If enabled, the Current Channel A and
Current Channel B IRMS measurements are continually accu-
mulated instead of the apparent power. If enabled, the apparent
power CF output pin also reflects the ampere-hour measurement
(see the Energy-to-Frequency Conversion section). All the signal
processing and calibration registers available for the apparent
power and apparent energy accumulation remain active when
the ampere-hour accumulation mode is enabled. This includes
the apparent energy no-load feature (see the Apparent Energy
No-Load section). Recalibration is required in this mode due
to internal scaling differences between the IRMS and apparent
signals.
the LCYCMODE register (Address 0x004) is set, the contents of
the APENERGYA and APENERGYB registers are cleared after
a read and remain at 0 until the end of the next line cycle period.
Rev. B | Page 32 of 72
相关PDF资料
PDF描述
RS-2412DZ/H3 CONV DC/DC 2W 9-36VIN +/-12VOUT
HMC12DTES CONN EDGECARD 24POS .100 EYELET
HMC49DREF-S13 CONN EDGECARD 98POS .100 EXTEND
ESC26DTEF CONN EDGECARD 52POS .100 EYELET
AISC-0402-2N0J-T INDUCTOR WW CERAM 2.0NH 0402
相关代理商/技术参数
参数描述
ADE7953ACPZ-RL 功能描述:IC ENERGY METERING 1PH 28LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7978ACPZ 制造商:Analog Devices 功能描述:
ADE7978ACPZ-RL 功能描述:3 Phase Meter IC 28-LFCSP-WQ (5x5) 制造商:analog devices inc. 系列:- 包装:带卷(TR) 零件状态:在售 输入阻抗:280 千欧 测量误差:- 电压 - I/O 高:2.4V 电压 - I/O 低:0.8V 电流 - 电源:10.6mA 电压 - 电源:2.97 V ~ 3.63 V 表计类型:3 相 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:28-WFQFN 裸露焊盘,CSP 供应商器件封装:28-LFCSP-WQ(5x5) 标准包装:5,000
ADE8052-DWDL1 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC, and LCD Driver
ADE8052-EMUL1 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC, and LCD Driver