参数资料
型号: ADE7953ACPZ
厂商: Analog Devices Inc
文件页数: 38/72页
文件大小: 0K
描述: IC ENERGY METERING 1PH 28LFCSP
标准包装: 1
输入阻抗: 660 千欧
测量误差: 0.1%
电压 - 高输入/输出: 2.4V
电压 - 低输入/输出: 0.4V
电流 - 电源: 6.8mA
电源电压: 3 V ~ 3.6 V
测量仪表类型: 单相
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 28-WFQFN 裸露焊盘,CSP
供应商设备封装: 28-LFCSP-WQ(5x5)
包装: 托盘

ADE7953
POWER FACTOR
The ADE7953 provides a direct power factor measurement
simultaneously on Current Channel A and Current Channel B.
Power factor in an ac circuit is defined as the ratio of the active
power flowing to the load to the apparent power. The power
factor measurement is defined in terms of “leading” or “lagging,”
referring to whether the current waveform is leading or lagging
the voltage waveform.
When the current waveform is leading the voltage waveform,
the load is capacitive and is defined as a negative power factor.
When the current waveform is lagging the voltage waveform,
the load is inductive and is defined as a positive power factor.
The relationship of the current waveform to the voltage wave-
form is illustrated in Figure 59.
Data Sheet
By default, the instantaneous active and apparent power
readings are used to calculate the power factor, and the register
is updated at a rate of 6.99 kHz. The sign bit is taken from the
instantaneous reactive energy measurement on each channel.
USING THE LINE CYCLE ACCUMULATION MODE
TO DETERMINE THE POWER FACTOR
If a power factor measurement with more averaging is required,
the ADE7953 can use the line cycle accumulation measurement
on the active and apparent energies to determine the power factor
(see the Active Energy Line Cycle Accumulation Mode section
and the Apparent Energy Line Cycle Accumulation Mode section).
This option provides a more stable power factor reading.
To use the line cycle accumulation mode to determine the power
ACTIVE (–)
REACTIVE (–)
ACTIVE (+)
REACTIVE (–)
factor, the ADE7953 must be configured as follows:
I
+60° = θ; PF = –0.5
–60° = θ; PF = +0.5
V
CAPACITIVE LOAD:
CURRENT LEADS
VOLTAGE
INDUCTIVE LOAD:
CURRENT LAGS
?
?
The PFMODE bit (Bit 3) must be set to 1 in the CONFIG
register (Address 0x102).
The line cycle accumulation mode must be enabled on
both the active and apparent energies by setting the
xLWATT and xLVA bits to 1 in the LCYCMODE register
(Address 0x004).
I VOLTAGE
ACTIVE (–) ACTIVE (+)
REACTIVE (+) REACTIVE (+)
Figure 59. Capacitive and Inductive Loads
As shown in Figure 59, the reactive power measurement is
negative when the load is capacitive and positive when the
load is inductive. The sign of the reactive power can therefore
be used to reflect the sign of the power factor.
The mathematical definition of power factor is shown in
Equation 37.
When using line cycle accumulation to determine the power
factor, the update rate of the power factor measurement is an
integral number of half line cycles. The number of half line cycles
is programmed in the LINECYC register (Address 0x101). For
complete information about setting up the line cycle accumula-
Mode section.
POWER FACTOR WITH NO-LOAD DETECTION
Power Factor = ( Sign of Reactive Power ) ×
| Active Power |
Apparent Power
(37)
The power factor measurement is affected by the no-load
condition if no-load detection is enabled (see the No-Load
The absolute value of active power is used.
The power factor measurement includes the effect of all
harmonics over the 1.23 kHz bandwidth.
The power factor readings are stored in two 16-bit, signed
registers: PFA (Address 0x10A) for Current Channel A and
PFB (Address 0x10B) for Current Channel B. These registers are
signed, twos complement registers with the MSB indicating the
polarity of the power factor. Each LSB of the PFx register equates
to a weight of 2 ?15 ; therefore, the maximum register value of
0x7FFF corresponds to a power factor value of 1. The minimum
register value of 0x8000 corresponds to a power factor of ?1.
Detection section). The following considerations apply only
when no-load detection is enabled and a no-load condition
occurs:
? If the apparent energy no-load condition is true, the power
factor measurement is set to 1 because it is assumed that
there is no active or reactive power.
? If the active energy no-load condition is true, the power
factor measurement is set to 0 because it is assumed that
the load is purely capacitive or inductive.
? If the reactive energy no-load condition is true, the sign of
the power factor is based on the sign of the active power.
Rev. B | Page 38 of 72
相关PDF资料
PDF描述
RS-2412DZ/H3 CONV DC/DC 2W 9-36VIN +/-12VOUT
HMC12DTES CONN EDGECARD 24POS .100 EYELET
HMC49DREF-S13 CONN EDGECARD 98POS .100 EXTEND
ESC26DTEF CONN EDGECARD 52POS .100 EYELET
AISC-0402-2N0J-T INDUCTOR WW CERAM 2.0NH 0402
相关代理商/技术参数
参数描述
ADE7953ACPZ-RL 功能描述:IC ENERGY METERING 1PH 28LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7978ACPZ 制造商:Analog Devices 功能描述:
ADE7978ACPZ-RL 功能描述:3 Phase Meter IC 28-LFCSP-WQ (5x5) 制造商:analog devices inc. 系列:- 包装:带卷(TR) 零件状态:在售 输入阻抗:280 千欧 测量误差:- 电压 - I/O 高:2.4V 电压 - I/O 低:0.8V 电流 - 电源:10.6mA 电压 - 电源:2.97 V ~ 3.63 V 表计类型:3 相 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:28-WFQFN 裸露焊盘,CSP 供应商器件封装:28-LFCSP-WQ(5x5) 标准包装:5,000
ADE8052-DWDL1 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC, and LCD Driver
ADE8052-EMUL1 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC, and LCD Driver