参数资料
型号: ADM1276-3ACPZ-RL
厂商: Analog Devices Inc
文件页数: 24/48页
文件大小: 0K
描述: IC HOT SWAP CTLR PMBUS 20LFCSP
标准包装: 5,000
类型: 热交换控制器
应用: 通用
内部开关:
电流限制: 可调
电源电压: 2.95 V ~ 20 V
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 20-WQFN 裸露焊盘,CSP
供应商设备封装: 20-LFCSP-WQ(5x5)
包装: 带卷 (TR)

ADM1276
PMBus INTERFACE
The I 2 C bus is a common, simple serial bus used by many devices
to communicate. It defines the electrical specifications, the bus
timing, the physical layer, and some basic protocol rules.
SMBus is based on I 2 C and aims to provide a more robust and
fault tolerant bus. Functions such as bus timeout and packet
error checking are added to help achieve this robustness, along
with more specific definitions of the bus messages used to read
and write data to devices on the bus.
PMBus is layered on top of SMBus and, in turn, on I 2 C. Using the
SMBus defined bus messages, PMBus defines a set of standard
commands that can be used to control a device that is part of a
power chain.
The ADM1276 command set is based upon the PMBus? Power
System Management Protocol Specification , Part I and Part II,
Revision 1.2. This version of the standard is intended to provide
a common set of commands for communicating with dc-to-dc
type devices. However, many of the standard PMBus commands
can be mapped directly to the functions of a hot swap controller.
Part I and Part II of the PMBus standard describe the basic
commands and how they can be used in a typical PMBus setup.
The following sections describe how the PMBus standard and
the ADM1276 specific commands are used.
DEVICE ADDRESSING
The ADM1276 is available in one model: the ADM1276 -3. The
PMBus address is 7 bits in size. The upper 5 bits (MSBs) of the
address word are fixed. The base address for the ADM1276 is
01000xx (0x20).
The ADM1276 has a single ADR pin that is used to select one of
four possible addresses. The ADR pin connection selects the
lowest two bits (LSBs) of the 7-bit address word (see Table 6).
Table 6. PMBus Addresses and ADR Pin Connection
Value of Address LSBs ADR Pin Connection
Data Sheet
PACKET ERROR CHECKING
The ADM1276 PMBus interface supports the use of the packet
error checking (PEC) byte that is defined in the SMBus standard.
The PEC byte is transmitted by the ADM1276 during a read
transaction or sent by the bus host to the ADM1276 during a
write transaction. The ADM1276 supports the use of PEC with
all the SMBus protocols that it implements.
The use of the PEC byte is optional. The bus host can decide
whether to use the PEC byte with the ADM1276 on a message-
by-message basis. There is no need to enable or disable PEC in
The PEC byte is used by the bus host or the ADM1276 to detect
errors during a bus transaction, depending on whether the trans-
action is a read or a write. If the host determines that the PEC
byte read during a read transaction is incorrect, it can decide to
repeat the read if necessary. If the ADM1276 determines that the
PEC byte sent during a write transaction is incorrect, it ignores
the command (does not execute it) and sets a status flag.
Within a group command, the host can choose to send or not
send a PEC byte as part of the message to the ADM1276 .
PARTIAL TRANSACTIONS ON I 2 C BUS
In the event of a specific sequence of events occurring on the
I 2 C bus, it is possible for the I 2 C interface on the device to go
into a state where it will fail to acknowledge the next I 2 C
transaction directed to it. There are two ways that this behavior
can be triggered:
? A partial I 2 C transaction consisting of a start condition,
followed by a single SCL clock pulse and stop condition.
? If the I 2 C bus master does not follow the 300 ns SDA data
hold time when signaling the ACK/NACK bit at the end of
a transaction. The device sees this as a single SCL clock
partial transaction.
00
01
10
11
Connect to GND
150 k? resistor to GND
No connection (floating)
Connect to VCAP
In the event that the device does not acknowledge a transaction,
then the I 2 C interface on the device can be reset by sending a
series of up to 16 SCL clock pulses, or performing a dummy
transaction to another I 2 C address on the bus.
SMBus PROTOCOL USAGE
All I 2 C transactions on the ADM1276 are done using SMBus
defined bus protocols. The following SMBus protocols are
implemented by the ADM1276 :
?
?
?
?
?
?
?
Send byte
Receive byte
Write byte
Read byte
Write word
Read word
Block read
Rev. C | Page 24 of 48
相关PDF资料
PDF描述
R05P205S/P CONV DC/DC 2W 05VIN 05VOUT
VI-22Y-CX-F2 CONVERTER MOD DC/DC 3.3V 49.5W
2-530666-6 CONN LOW PRO 22 POS 156X200C/L
ESC08DRYS CONN EDGECARD 16POS DIP .100 SLD
MIC2586R-2YM IC CTRLR/SEQ HOT SWAP 14-SOIC
相关代理商/技术参数
参数描述
ADM1278-1AACPZ 功能描述:Hot Swap Controller, Monitor 1 Channel General Purpose 32-LFCSP (5x5) 制造商:analog devices inc. 系列:- 包装:托盘 零件状态:有效 类型:热交换控制器,监控器 通道数:1 内部开关:无 应用:通用 特性:PMBus 可编程特性:自动重试,限流,故障超时,闭锁故障,OVP,压摆率,UVLO 电压 - 电源:4.5 V ~ 20 V 电流 - 输出(最大值):- 工作温度:-40°C ~ 85°C 电流 - 电源:5.5mA 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP(5x5) 功能引脚:- 标准包装:1
ADM1278-1AACPZ-RL 功能描述:Hot Swap Controller, Monitor 1 Channel General Purpose 32-LFCSP-WQ (5x5) 制造商:analog devices inc. 系列:- 包装:带卷(TR) 零件状态:有效 类型:热交换控制器,监控器 通道数:1 内部开关:无 应用:通用 特性:PMBus 可编程特性:自动重试,限流,故障超时,闭锁故障,OVP,压摆率,UVLO 电压 - 电源:4.5 V ~ 20 V 电流 - 输出(最大值):- 工作温度:-40°C ~ 85°C 电流 - 电源:5.5mA 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP-WQ(5x5) 功能引脚:- 标准包装:5,000
ADM1278-1ACPZ 功能描述:Hot Swap Controller, Monitor 1 Channel General Purpose 32-LFCSP (5x5) 制造商:analog devices inc. 系列:- 包装:托盘 零件状态:有效 类型:热交换控制器,监控器 通道数:1 内部开关:无 应用:通用 特性:PMBus 可编程特性:自动重试,限流,故障超时,闭锁故障,OVP,压摆率,UVLO 电压 - 电源:4.5 V ~ 20 V 电流 - 输出(最大值):- 工作温度:-40°C ~ 85°C 电流 - 电源:5.5mA 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP(5x5) 功能引脚:- 标准包装:1
ADM1278-1ACPZ-RL 功能描述:IC ENERGY MON HOT-SWAP 32-LFCSP 制造商:analog devices inc. 系列:- 包装:剪切带(CT) 零件状态:在售 类型:热交换控制器,监控器 通道数:1 内部开关:无 应用:通用 特性:PMBus 可编程特性:自动重试,限流,故障超时,闭锁故障,OVP,压摆率,UVLO 电压 - 电源:4.5 V ~ 20 V 电流 - 输出(最大值):- 工作温度:-40°C ~ 85°C 电流 - 电源:5.5mA 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP-WQ(5x5) 功能引脚:- 标准包装:1
ADM1278-1BCPZ 功能描述:Hot Swap Controller, Monitor 1 Channel General Purpose 32-LFCSP (5x5) 制造商:analog devices inc. 系列:- 包装:托盘 零件状态:有效 类型:热交换控制器,监控器 通道数:1 内部开关:无 应用:通用 特性:PMBus 可编程特性:自动重试,限流,故障超时,闭锁故障,OVP,压摆率,UVLO 电压 - 电源:4.5 V ~ 20 V 电流 - 输出(最大值):- 工作温度:-40°C ~ 85°C 电流 - 电源:5.5mA 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP(5x5) 功能引脚:- 标准包装:1