参数资料
型号: ADM1276-3ACPZ-RL
厂商: Analog Devices Inc
文件页数: 28/48页
文件大小: 0K
描述: IC HOT SWAP CTLR PMBUS 20LFCSP
标准包装: 5,000
类型: 热交换控制器
应用: 通用
内部开关:
电流限制: 可调
电源电压: 2.95 V ~ 20 V
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 20-WQFN 裸露焊盘,CSP
供应商设备封装: 20-LFCSP-WQ(5x5)
包装: 带卷 (TR)
ADM1276
bits, as well as pointer bits that indicate whether any of the four
other status registers need to be read for more detailed status
information.
In the ADM1276 , a particular distinction is made between
faults and warnings. A fault is always generated by the hot swap
controller and is defined by hardware component values. Three
events can generate a fault:
? Overcurrent condition that causes the hot swap timer to
time out.
? Overvoltage condition on the OV pin.
? Undervoltage condition on the UV pin.
When a fault occurs, the hot swap controller always takes
some action, usually to turn off the GATE pin, which is
driving the FET. A fault can also generate an SMBAlert on
the GPO2/ALERT2 pin.
All warnings in the ADM1276 are generated by the power
monitor, which samples the voltage and current and then
compares these measurements to the threshold values set by the
various limit commands. A warning has no effect on the hot
swap controller, but it may generate an SMBAlert on the
GPO2/ALERT2 output pin.
When a status bit is set, it always means that the status condition—
fault or warning—is active or was active at some point in the past.
When a fault or warning bit is set, it is latched until it is explicitly
cleared using either the OPERATION or the CLEAR_FAULTS
command. Some other status bits are live, that is, they always
reflect a status condition and are never latched.
STATUS_BYTE and STATUS_WORD Commands
The STATUS_BYTE and STATUS_WORD commands can
be used to obtain a snapshot of the overall part status. These
commands indicate whether it is necessary to read more
detailed information using the other status commands.
The low byte of the word returned by the STATUS_WORD
command is the same byte returned by the STATUS_BYTE
command. The high byte of the word returned by the
STATUS_WORD command provides a number of bits that
can be used to determine which of the other status commands
needs to be issued to obtain all active status bits.
STATUS_INPUT Command
The STATUS_INPUT command returns a number of bits
relating to voltage faults and warnings on the input supply.
STATUS_VOUT Command
The STATUS_VOUT command returns a number of bits
relating to voltage faults and warnings on the output supply.
STATUS_IOUT Command
The STATUS_IOUT command returns a number of bits
relating to current faults and warnings on the output supply.
Data Sheet
STATUS_MFR_SPECIFIC Command
The STATUS_MFR_SPECIFIC command is a standard PMBus
command, but the contents of the byte returned are specific to
CLEAR_FAULTS Command
The CLEAR_FAULTS command is used to clear fault and
warnings bits when they are set. Fault and warnings bits are
latched when they are set. In this way, a host can read the bits
any time after the fault or warning condition occurs and
determine which problem actually occurred.
If the CLEAR_FAULTS command is issued and the fault or
warning condition is no longer active, the status bit is cleared.
If the condition is still active—for example, if an input voltage
is below the undervoltage threshold of the UV pin—the
CLEAR_FAULTS command attempts to clear the status bit, but
that status bit is immediately set again.
GPO AND ALERT PIN SETUP COMMANDS
A multipurpose pin is provided on the ADM1276 :
GPO2/ALERT2. The GPO2/ALERT2 pin can be configured
over the PMBus in one of three output modes, as follows:
? General-purpose digital output.
? Output for generating an SMBAlert when one or more
fault/warning status bits become active in the PMBus
status registers.
? Digital comparator.
In digital comparator mode, the current, voltage, and power
warning thresholds are compared to the values read or calculated
by the ADM1276 . The comparison result sets the output high
or low according to whether the value is greater or less than
the warning threshold that has been set.
For an example of how to configure this pin to generate an
SMBAlert and how to respond and clear the condition, see the
ALERT2_CONFIG Command
Using combinations of bit masks, the ALERT2_CONFIG
command can be used to select the status bits that, when set,
generate an SMBAlert signal to a processor, or control the
digital comparator mode. They can also be used to set a GPO
mode on the GPO2/ALERT2 pin, so that it is under software
control. If this mode is set, the SMBAlert masking bits are
ignored.
POWER MONITOR COMMANDS
The ADM1276 provides a high accuracy, 12-bit current and
voltage power monitor. The power monitor can be configured
in a number of different modes of operation and can run in
either continuous mode or single shot mode with a number
of different sample averaging options.
Rev. C | Page 28 of 48
相关PDF资料
PDF描述
R05P205S/P CONV DC/DC 2W 05VIN 05VOUT
VI-22Y-CX-F2 CONVERTER MOD DC/DC 3.3V 49.5W
2-530666-6 CONN LOW PRO 22 POS 156X200C/L
ESC08DRYS CONN EDGECARD 16POS DIP .100 SLD
MIC2586R-2YM IC CTRLR/SEQ HOT SWAP 14-SOIC
相关代理商/技术参数
参数描述
ADM1278-1AACPZ 功能描述:Hot Swap Controller, Monitor 1 Channel General Purpose 32-LFCSP (5x5) 制造商:analog devices inc. 系列:- 包装:托盘 零件状态:有效 类型:热交换控制器,监控器 通道数:1 内部开关:无 应用:通用 特性:PMBus 可编程特性:自动重试,限流,故障超时,闭锁故障,OVP,压摆率,UVLO 电压 - 电源:4.5 V ~ 20 V 电流 - 输出(最大值):- 工作温度:-40°C ~ 85°C 电流 - 电源:5.5mA 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP(5x5) 功能引脚:- 标准包装:1
ADM1278-1AACPZ-RL 功能描述:Hot Swap Controller, Monitor 1 Channel General Purpose 32-LFCSP-WQ (5x5) 制造商:analog devices inc. 系列:- 包装:带卷(TR) 零件状态:有效 类型:热交换控制器,监控器 通道数:1 内部开关:无 应用:通用 特性:PMBus 可编程特性:自动重试,限流,故障超时,闭锁故障,OVP,压摆率,UVLO 电压 - 电源:4.5 V ~ 20 V 电流 - 输出(最大值):- 工作温度:-40°C ~ 85°C 电流 - 电源:5.5mA 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP-WQ(5x5) 功能引脚:- 标准包装:5,000
ADM1278-1ACPZ 功能描述:Hot Swap Controller, Monitor 1 Channel General Purpose 32-LFCSP (5x5) 制造商:analog devices inc. 系列:- 包装:托盘 零件状态:有效 类型:热交换控制器,监控器 通道数:1 内部开关:无 应用:通用 特性:PMBus 可编程特性:自动重试,限流,故障超时,闭锁故障,OVP,压摆率,UVLO 电压 - 电源:4.5 V ~ 20 V 电流 - 输出(最大值):- 工作温度:-40°C ~ 85°C 电流 - 电源:5.5mA 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP(5x5) 功能引脚:- 标准包装:1
ADM1278-1ACPZ-RL 功能描述:IC ENERGY MON HOT-SWAP 32-LFCSP 制造商:analog devices inc. 系列:- 包装:剪切带(CT) 零件状态:在售 类型:热交换控制器,监控器 通道数:1 内部开关:无 应用:通用 特性:PMBus 可编程特性:自动重试,限流,故障超时,闭锁故障,OVP,压摆率,UVLO 电压 - 电源:4.5 V ~ 20 V 电流 - 输出(最大值):- 工作温度:-40°C ~ 85°C 电流 - 电源:5.5mA 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP-WQ(5x5) 功能引脚:- 标准包装:1
ADM1278-1BCPZ 功能描述:Hot Swap Controller, Monitor 1 Channel General Purpose 32-LFCSP (5x5) 制造商:analog devices inc. 系列:- 包装:托盘 零件状态:有效 类型:热交换控制器,监控器 通道数:1 内部开关:无 应用:通用 特性:PMBus 可编程特性:自动重试,限流,故障超时,闭锁故障,OVP,压摆率,UVLO 电压 - 电源:4.5 V ~ 20 V 电流 - 输出(最大值):- 工作温度:-40°C ~ 85°C 电流 - 电源:5.5mA 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP(5x5) 功能引脚:- 标准包装:1