TMS470R1VF336A, TMS470R1VF346A
16/32-BIT RISC FLASH MICROCONTROLLERS
SPNS079I – OCTOBER 2002 – REVISED SEPTEMBER 2006
23
POST OFFICE BOX 1443
HOUSTON, TEXAS 77251-1443
DEVICE ELECTRICAL SPECIFICATIONS AND TIMING PARAMETERS
absolute maximum ratings over operating free-air temperature range, Q version
(unless otherwise noted)
Supply voltage ranges: VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 2.5 V Supply voltage ranges: VCCIO, VCCAD, VCCP (flash pump) (see Note 1) . . . . . . . . . . . . . . . . . . 0.5 V to 4.1 V Input voltage range: All input pins
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 4.1 V
Input clamp current: IIK (VI < 0 or VI > VCCIO)
All pins except ADIN[0:11], PORRST, TRST, TEST and TCK . . . . . . . . . . . . . . .
±20 mA
IIK (VI < 0 or VI > VCCAD)
ADIN[0:11] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±10 mA
Operating free-air temperature ranges, TA: A version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40°C to 85°C
T version
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40°C to 105°C
Q version
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40°C to 125°C
Operating junction temperature range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40°C to 150°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40°C to 150°C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is
not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to their associated grounds.
device recommended operating conditions
All voltages are with respect to VSS, except VCCAD, which is with respect to VSSAD.
MIN
NOM
MAX
UNIT
VCC
Digital logic (and flash supply voltage for
VF3x6A) (Core)
40C to 125C
1.81
2.06
V
40C to 85C (VF3x6xE only)
1.70
2.06
V
VCCIO
Digital logic supply voltage (I/O)
33.3
3.6
V
VCCAD
ADC supply voltage
33.3
3.6
V
VCCP
Flash pump supply voltage (VF3x6A only)
33.3
3.6
V
VSS
Digital logic supply ground
0
V
VSSAD
ADC supply ground
0.1
0.1
V
TA
Operating free-air temperature
A version
40
85
°C
T version
40
105
Q version
40
125
TJ
Operating junction temperature
40
150
°C