参数资料
型号: 71M6511-IGTR/F
厂商: MAXIM INTEGRATED PRODUCTS INC
元件分类: 电源管理
英文描述: 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, PQFP64
封装: LEAD FREE, LQFP-64
文件页数: 62/98页
文件大小: 1278K
代理商: 71M6511-IGTR/F
71M6511/71M6511H
Single-Phase Energy Meter IC
DATA SHEET
NOVEMBER 2010
Page: 65 of 98
2005–2010 Teridian Semiconductor Corporation
V2.7
A Maxim Integrated Products Brand
CE Program and Environment
CE Program
The CE program is supplied by TERIDIAN as a data image that can be merged with the MPU operational code for meter
applications. Typically, the CE program covers most applications and does not need to be modified. The description in this
section applies to CE code revision CE11B05.
Formats
All CE words are 4 bytes. Unless specified otherwise, they are in 32-bit two’s complement (-1 = 0xFFFFFFFF). ‘Calibration’
parameters are defined in flash memory (or external EEPROM) and must be copied to CE memory by the MPU before
enabling the CE. ‘Internal’ variables are used in internal CE calculations. ‘Input’ variables allow the MPU to control the
behavior of the CE code. ‘Output’ variables are outputs of the CE calculations. The corresponding MPU address for the most
significant byte is given by 0x1000 + 4 x CE_address and 0x1003 + 4 x CE_address for the least significant byte.
Constants
Constants used in the CE Data Memory tables are:
Sampling frequency: FS = 32768Hz/13 = 2520.62Hz (MUX_DIV = 1) or 32786/10 = 3276.8Hz (MUX_DIV = 2)
F0 is the fundamental signal frequency, typically 50 or 60Hz.
IMAX is the external rms current corresponding to 250mV peak at the inputs IA or IB.
VMAX is the external rms voltage corresponding to 250mV peak at the input VA.
NACC, the accumulation count for energy measurements is PRE_SAMPS*SUM_CYCLES. This value resides in
SUM_PRE (CE address 36).
Accumulation count time for energy measurements is PRE_SAMPS*SUM_CYCLES/FS.
In_8 is a gain constant of current channel n. Its value is 8 or 1 and is controlled by In_SHUNT.
X is a gain constant of the pulse generators. Its value is determined by PULSE_FAST and PULSE_SLOW.
Voltage LSB = VMAX * 3.3243*10
-9 V (peak).
The system constants IMAX and VMAX are used by the MPU to convert internal digital quantities (as used by the CE) to
external, i.e. metering quantities. Their values are determined by the scaling of the voltage and current sensors used in an
actual meter. The LSB values used in this document relate digital quantities at the CE or MPU interface to external meter input
quantities. For example, if a SAG threshold of 80V peak is desired at the meter input, the digital value that should be pro-
grammed into SAG_THR would be 80V/SAG_THRLSB, where SAG_THRLSB is the LSB value in the description of SAG_THR.
The parameters EQU, CE_EN, PRE_SAMPS, and SUM_CYCLES are essential to the function of the CE and are stored in I/O
RAM (see I/O RAM section).
相关PDF资料
PDF描述
71M6511-IGT/F 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, PQFP64
71M6511-IGT 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, PQFP64
71M6511-IGTR 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, PQFP64
71M6511H-IGTR/F 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, PQFP64
71M6511H-IGT/F 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, PQFP64
相关代理商/技术参数
参数描述
71M6512-DB 制造商:Maxim Integrated Products 功能描述:Development Boards & Kits - 8051 71M6512 Demo Brd
71M6512-IM/F 制造商:Maxim Integrated Products 功能描述:Metering Systems on a Chip - SoC Residential Meter Extended Io
71M6512-IMR/F 制造商:Maxim Integrated Products 功能描述:Metering Systems on a Chip - SoC Residential Meter Extended Io
71M6512-TGQ1-68M 功能描述:程序设计器配件 Gang Programmer Base Unit+6512 Socket Brd RoHS:否 制造商:Lattice 产品:ispDOWNLOAD Cables 用于:In-system Programming
71M6513 制造商:未知厂家 制造商全称:未知厂家 功能描述:71M6513