71M6545/71M6545H Data Sheet
The CE pulse generator can be controlled by either the MPU (external) or CE (internal) variables. Control is by
the MPU if the EXT _ PULSE bit = 1 ( CE RAM 0x20[5] ). In this case, the MPU controls the pulse rate (external
pulse generation) by placing values into APULSEW and APULSER (CE RAM 0x45 and 0x49) . By setting
EXT _ PULSE = 0, the CE controls the pulse rate based on WSUM_X (CE RAM 0x84) and VARSUM_X (CE
RAM 0x88).
Table 69: Sag Threshold, Phase Measurement, and Gain Adjust Control
?? ?????? ?√2
?????????7 . 8798?10 ?9
CE
Address
0x24
0x40
0x41
0x42
0x43
0x44
Name
SAG_THR
GAIN_ADJ0
GAIN_ADJ1
GAIN_ADJ2
GAIN_ADJ3
GAIN_ADJ4
Default
2.39*10 7
16384
16384
16384
16384
16384
Description
The voltage threshold for sag warnings. The default value is
equivalent to 80 V RMS if VMAX = 600 V.
SAG_THR =
The assignments of these gain adjustments depends on the
meter design. See 4.5.5 Temperature Compensation for VREF
and Shunt Sensors on page 75 or 4.5.6 Temperature
Compensation of VREF and Current Transformers on page 77.
The default value of 16384 corresponds to unity gain.
5.4.8
CE Transfer Variables
When the MPU receives the XFER_BUSY interrupt, it knows that fresh data is available in the transfer
variables. CE transfer variables are modified during the CE code pass that ends with an XFER_BUSY
interrupt. They remain constant throughout each accumulation interval. In this data sheet, the names of
CE transfer variables always end with _X. The transfer variables can be categorized as:
?
?
?
Fundamental energy measurement variables
Instantaneous (RMS) values
Other measurement parameters
Fundamental Energy Measurement Variables
Table 70 describes each transfer variable for fundamental energy measurement. All variables are signed
32-bit integers. Accumulated variables such as WSUM are internally scaled so they have at least 2x
margin before overflow when the integration time is one second. Additionally, the hardware does not permit
output values to fold back upon overflow.
Table 70: CE Transfer Variables (with Shunts)
CE
Address
0x84
0x85
0x86
0x87
0x88
0x89
0x8A
0x8B
v2
Name
WSUM_X
W0SUM_X
W1SUM_X
W2SUM_X
VARSUM_X
VAR0SUM_X
VAR1SUM_X
VAR2SUM_X
Description
The signed sum: W0SUM_X+W1SUM_X+W2SUM_X .
The sum of Wh samples from each wattmeter
element.
LSB W = 7.7562*10 -13 VMAX * IMAX Wh.
The signed sum:
VAR0SUM_X+VAR1SUM_X+VAR2SUM_X.
The sum of VARh samples from each wattmeter
element.
LSB W = 7.7562*10 -13 VMAX * IMAX VARh.
Configuration
Figure 27 (page 72 )
105
相关PDF资料
PDF描述
T95S224M035LZAL CAP TANT 0.22UF 35V 20% 1507
GBC12DCSN-S288 CONN EDGECARD 24POS .100 EXTEND
78M6612-M/F/P2 IC PWR MEASUREMENT AC 68SQFN
V48C28H75BL2 CONVERTER MOD DC/DC 28V 75W
ISL6613IRZ-T IC MOSFET DRVR SYNC BUCK 10-DFN
相关代理商/技术参数
参数描述
71M6545T-IGT/F 制造商:Maxim Integrated Products 功能描述:METROLOGY PROCESSORS - Rail/Tube
71M6545T-IGTR/F 制造商:Maxim Integrated Products 功能描述:3-PHASE AFE, 32KB FLASH, PRES TEMP SENSOR - Tape and Reel
71M6601 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:On-Chip Temperature Sensor Enables Localized Digital Temperature On-Chip Power Monitoring
71M6601-IF 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:On-Chip Temperature Sensor Enables Localized Digital Temperature On-Chip Power Monitoring
71M6601-IL 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:On-Chip Temperature Sensor Enables Localized Digital Temperature On-Chip Power Monitoring