参数资料
型号: ADE7763ARSZ
厂商: Analog Devices Inc
文件页数: 31/56页
文件大小: 0K
描述: IC ENERGY METERING 1PHASE 20SSOP
标准包装: 66
输入阻抗: 390 千欧
测量误差: 0.1%
电压 - 高输入/输出: 2.4V
电压 - 低输入/输出: 0.8V
电流 - 电源: 3mA
电源电压: 4.75 V ~ 5.25 V
测量仪表类型: 单相
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 20-SSOP(0.209",5.30mm 宽)
供应商设备封装: 20-SSOP
包装: 管件
产品目录页面: 797 (CN2011-ZH PDF)
配用: EVAL-ADE7763ZEB-ND - BOARD EVALUATION FOR ADE7763
Data Sheet
LINE CYCLE ENERGY ACCUMULATION MODE
In line cycle energy accumulation mode, the energy accumu-
lation of the ADE7763 can be synchronized to the Channel 2
zero crossing so that active energy accumulates over an integral
number of half line cycles. The advantage of summing the active
energy over an integral number of line cycles is that the
sinusoidal component in the active energy is reduced to 0. This
eliminates ripple in the energy calculation. Energy is calculated
more accurately and in a shorter time because the integration
period is shortened. By using the line cycle energy accumulation
mode, the energy calibration can be greatly simplified, and the
time required to calibrate the meter can be significantly reduced.
The ADE7763 is placed in line cycle energy accumulation mode
by setting Bit 7 (CYCMODE) in the mode register. In line cycle
energy accumulation mode, the ADE7763 accumulates the
active power signal in the LAENERGY register (Address 0x04)
for an integral number of line cycles, as shown in Figure 61. The
number of half line cycles is specified in the LINECYC register
(Address 0x1C). The ADE7763 can accumulate active power for
up to 65,535 half line cycles. Because the active power is
integrated on an integral number of line cycles, the CYCEND
flag in the interrupt status register is set (Bit 2) at the end of a
line cycle energy accumulation cycle. If the CYCEND enable bit
in the interrupt enable register is enabled, the IRQ output also
will go active low. Therefore, the IRQ line can also be used to
signal the completion of the line cycle energy accumulation.
Another calibration cycle can start as long as the CYCMODE
bit in the mode register is set.
From Equations 13 and 18,
ADE7763
Note that in this mode, the 16-bit LINECYC register can hold a
maximum value of 65,535. In other words, the line energy
accumulation mode can be used to accumulate active energy for
a maximum duration of 65,535 half line cycles. At 60 Hz line
frequency, this translates to a total duration of 65,535/
120 Hz = 546 seconds.
POSITIVE-ONLY ACCUMULATION MODE
In positive-only accumulation mode, the active energy
accumulation is only done for positive power, ignoring any
occurrence of negative power above or below the no-load
threshold, as shown in Figure 62. The CF pulse also reflects this
accumulation method when in this mode. Positive-only
accumulation mode is activated by setting the MSB of the mode
register (MODE[15]) and effects only the active power. The
default setting for this mode is off. Transitions in the direction
of power flow, going from negative to positive or positive to
negative, set the IRQ pin to active low if the PPOS and PNEG
bits are set in the interrupt enable register. The corresponding
PPOS and PNEG bits in the interrupt status register show
which transition has occurred—see the register descriptions in
ACTIVE ENERGY
?
? ?
?
E ( t ) ? VI dt ? ?
? f ?
? 1 ? ?
?
? nT
?
? ?
?
?
nT
0
?
?
?
? ? 8 . 9 ?
VI
2
?
? ? cos( 2 ? f t ) dt
0
? ?
(20)
NO-LOAD
THRESHOLD
ACTIVE POWER
NO-LOAD
THRESHOLD
where:
IRQ
n is an integer.
PPOS
PNEG
PPOS
PNEG PPOS PNEG
T is the line cycle period.
Since the sinusoidal component is integrated over an integral
number of line cycles, its value is always 0. Therefore,
INTERRUPT STATUS REGISTERS
Figure 62. Energy Accumulation in Positive-Only Accumulation Mode
NO-LOAD THRESHOLD
?
nT
E ? VIdt ? 0
0
E ? t ? ? VInT
(21)
(22)
The ADE7763 includes a no-load threshold feature on the
active energy that eliminates any creep effects in the meter. This
is accomplished because energy does not accumulate if the
multiplier output is below the no-load threshold. This threshold
is 0.001% of the full-scale output frequency of the multiplier.
Compare this value to the IEC1036 specification, which states
that the meter must start up with a load equal to or less than
0.4% I b . This standard translates to 0.0167% of the full-scale
output frequency of the multiplier.
Rev. C | Page 31 of 56
相关PDF资料
PDF描述
ISL6605IRZ IC MOSFET DRVR SYNC BUCK 8-QFN
CS5463-ISZ IC ENERGY METERING 1PHASE 24SSOP
RGM40DTAD-S189 CONN EDGECARD 80POS R/A .156 SLD
TTN0.38SV100 THERMASHIELD TUBE 3/8" SLV 100'
ADE7751ARSZ IC ENERGY METERING 1PHASE 24SSOP
相关代理商/技术参数
参数描述
ADE7763ARSZ 制造商:Analog Devices 功能描述:IC, SINGLE PHASE ENERGY METER, SSOP-20
ADE7763ARSZRL 功能描述:IC ENERGY METERING 1PHASE 20SSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7763ARSZRL 制造商:Analog Devices 功能描述:IC, SINGLE PHASE ENERGY METER, SSOP-20
ADE7768 制造商:AD 制造商全称:Analog Devices 功能描述:Energy Metering IC with Integrated Oscillator and Positive Power Accumulation
ADE7768AR 制造商:AD 制造商全称:Analog Devices 功能描述:Energy Metering IC with Integrated Oscillator and Positive Power Accumulation