参数资料
型号: ADE7763ARSZ
厂商: Analog Devices Inc
文件页数: 36/56页
文件大小: 0K
描述: IC ENERGY METERING 1PHASE 20SSOP
标准包装: 66
输入阻抗: 390 千欧
测量误差: 0.1%
电压 - 高输入/输出: 2.4V
电压 - 低输入/输出: 0.8V
电流 - 电源: 3mA
电源电压: 4.75 V ~ 5.25 V
测量仪表类型: 单相
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 20-SSOP(0.209",5.30mm 宽)
供应商设备封装: 20-SSOP
包装: 管件
产品目录页面: 797 (CN2011-ZH PDF)
配用: EVAL-ADE7763ZEB-ND - BOARD EVALUATION FOR ADE7763
ADE7763
Data Sheet
AENERGY expected = AENERGY nominal × ? ? 1 +
WGAIN ?
2 12
?
Watt Gain
The first step of calibrating the gain is to define the line voltage,
?
?
(36)
× cos( ? )
× ? ? 1 +
( CFNUM + 1 ) WGAIN ?
2 12
the base current, and the maximum current for the meter. A
meter constant, such as 3200 imp/kWh or 3.2 imp/Wh, needs to
be determined for CF. Note that the line voltage and the
maximum current scale to half of their respective analog input
ranges in this example.
The expected CF in Hz is
CF expected (Hz) =
MeterConst ant (imp/Wh ) × Load ( W )
(30)
3600 s/h
where:
? is the angle between I and V.
cos ( ? ) is the power factor.
The ratio of active energy LSBs per CF pulse is adjusted using
the CFNUM, CFDEN, and WDIV registers.
CF expected (Hz) = CF nominal × ?
( CFDEN + 1 ) ? ?
(37)
When calibrating with a reference meter, WGAIN is adjusted
until CF matches the reference meter pulse output. If an
accurate source is used to calibrate, WGAIN will be modified
until the active energy accumulation rate yields the expected CF
pulse rate.
The steps of designing and calibrating the active energy portion
of a meter with either a reference meter or an accurate source
are outlined in the following examples. The specifications for
this example are
Meter Constant: MeterConstant (imp/Wh) = 3.2
Base Current: I b = 10 A
Maximum Current: I MAX = 60 A
CF expected =
LAENERGY
Accumulati onTime (s)
× WDIV ×
( CFNUM + 1)
( CFDEN + 1 )
(31)
Line Voltage:
Line Frequency:
V nominal = 220 V
f l = 50 Hz
Load (W) × Accumulati on Time ( s )
LSB =
Wh
LAENERGY × 3600 s/h
LINECYC IB × Line Period ( s )
× cos( ? ) = 1 . 9556 Hz
Line Period (s) = PERIOD ×
(34)
The relationship between watt-hours accumulated and the
quantity read from AENERGY can be determined from the
amount of active energy accumulated over time with a
given load:
(32)
where Accumulation Time can be determined from the value in
the line period and the number of half line cycles fixed in the
LINECYC register.
Accumulation time (s) = (33)
2
The line period can be determined from the period register:
8
CLKIN
The AENERGY Wh/LSB ratio can also be expressed in terms of
the meter constant:
The first step in calibration with either a reference meter or an
accurate source is to calculate the CF denominator, CFDEN.
This is done by comparing the expected CF pulse output to the
nominal CF output with the default CFDEN = 0x3F and
CFNUM = 0x3F when the base current is applied.
The expected CF output for this meter with the base current
applied is 1.9556 Hz using Equation 30.
CF IB ( expected ) (Hz) =
3 . 200 imp/Wh × 10 A × 220 V
3600 s/h
Alternatively, CF expected can be measured from a reference meter
pulse output.
CF expected (Hz) = CF ref (38)
The maximum CF frequency measured without any frequency
division and with ac inputs at full scale is 23 kHz. For this
example, the nominal CF with the test current, I b , applied is
958 Hz. In this example the line voltage and maximum current
( CFNUM + 1 )
( CFDEN + 1 )
LSB
CF nominal (Hz) = 23 kHz × 1 2 × 1 2 ×
× WDIV
Wh = (35)
MeterConst ant (imp/Wh)
In a meter design, WDIV, CFNUM, and CFDEN should be kept
constant across all meters to ensure that the Wh/LSB constant is
maintained. Leaving WDIV at its default value of 0 ensures
scale half of their respective analog input ranges. The line
voltage and maximum current should not be fixed at the
maximum analog inputs to account for occurrences such as
spikes on the line.
I
I MAX
(39)
maximum resolution. The WDIV register is not included in the
CF signal chain, so it does not affect the frequency pulse output.
The WGAIN register is used to finely calibrate each meter. Cali-
brating the WGAIN register changes both CF and AENERGY for
a given load condition.
CF IB ( nominal ) (Hz) = 23 kHz × 1 2 × 1 2 × 10 60 = 958 Hz
The nominal CF on a sample set of meters should be measured
using the default CFDEN, CFNUM, and WDIV to ensure that
the best CFDEN is chosen for the design.
With the CFNUM register set to 0, CFDEN is calculated to be
489 for the example meter:
Rev. C | Page 36 of 56
相关PDF资料
PDF描述
ISL6605IRZ IC MOSFET DRVR SYNC BUCK 8-QFN
CS5463-ISZ IC ENERGY METERING 1PHASE 24SSOP
RGM40DTAD-S189 CONN EDGECARD 80POS R/A .156 SLD
TTN0.38SV100 THERMASHIELD TUBE 3/8" SLV 100'
ADE7751ARSZ IC ENERGY METERING 1PHASE 24SSOP
相关代理商/技术参数
参数描述
ADE7763ARSZ 制造商:Analog Devices 功能描述:IC, SINGLE PHASE ENERGY METER, SSOP-20
ADE7763ARSZRL 功能描述:IC ENERGY METERING 1PHASE 20SSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7763ARSZRL 制造商:Analog Devices 功能描述:IC, SINGLE PHASE ENERGY METER, SSOP-20
ADE7768 制造商:AD 制造商全称:Analog Devices 功能描述:Energy Metering IC with Integrated Oscillator and Positive Power Accumulation
ADE7768AR 制造商:AD 制造商全称:Analog Devices 功能描述:Energy Metering IC with Integrated Oscillator and Positive Power Accumulation