Register 0x6 allows the user to enable or disable any of the alarm flags that are not required. If disabled, that particular alarm no longer
flags on the appropriate open-drain pin; however, the alarm status is still available in both of the alarm status registers (Address 0x43 and
Address 0x44).
Table 22. Alarm Setup Register
Address
Default
Data Bits, MSB First
0x6
0x0000
Bit
Name
Function
15
Latched
TMPALM
Set this latched bit high to program the open-drain TMPALM alarm pin as a latched output;
leave low for an unlatched alarm pin (default).
14
Disable
TMPALM
Set this bit high to disable the open-drain TMPALM alarm pin; leave low to leave enabled (default).
13
Latched
OSALM
Set this latched bit high to program the OSALM as a latched alarm on the open-drain KELALM
pin; leave low for an unlatched alarm pin (default).
12
Disable
OSALM
Set this bit high to disable the OSALM alarm function flagging the open-drain KELALM pin;
leave low to remain enabled (default). The disable GRDALM, DUTALM, and OSALM alarm
functions share one open-drain KELALM alarm pin. These bits allow users to choose if they wish
to have all or selected information flagged to the alarm pin.
11
Latched
DUTALM
Set this latched bit high to program the DUTALM as a latched alarm on the open-drain KELALM
pin; leave low for an unlatched alarm pin (default).
10
Disable
DUTALM
Set this bit high to disable the DUTALM alarm function flagging the open-drain KELALM pin.
Leave low to leave enabled (default). The disable GRDALM, DUTALM, and OSALM alarm
functions share one open drain KELALM alarm pin. These bits allow users to choose if they wish
to have all or any information flagged to the alarm pin. The DUTGND pin has a 50 A pull-up to
allow for detection of an error in the DUTGND path. Setting this bit high also disables the 50 A
pull-up.
9
Latched
CLALM
Set this latched bit high to program the open-drain CLALM clamp alarm pin as a latched
output; leave low for an unlatched alarm pin (default).
8
Disable
CLALM
Set this bit high to disable the open drain CLALM alarm pin; leave low to leave enabled (default).
7
Latched
GRDALM
Set this latched bit high to program the GRDALM as a latched alarm on the open-drain KELALM
pin; leave low for an unlatched alarm pin (default).
6
Disable
GRDALM
Set this bit high to disable the GRDALM alarm function flagging the open-drain KELALM pin;
leave low to leave enabled (default). The disable GRDALM, DUTALM and OSALM alarm functions
share one open-drain KELALM alarm pin. These bits allow users to choose if they wish to have
all or any information flagged to the KELALM alarm pin.
5:0
Unused
Set to 0.
相关PDF资料
PDF描述
EVAL-AD5522EBDZ BOARD EVAL FOR 14X14MM AD5522
EVAL-AD5520EBZ BOARD EVAL FOR AD5520
MAX6198AESA+T IC VREF SERIES PREC 4.096V 8SOIC
QPI-5-EVAL1 EVALUATION BOARD FOR QPI-5
H6MMH-4006M DIP CABLE - HDM40H/AE40M/HDM40H
相关代理商/技术参数
参数描述
EVAL-AD5570EB 制造商:Analog Devices 功能描述:DEV TOOLS, TRUE ACCURACY, 16BIT 12V/ 15V, SERL INPUT VOLT O - Bulk
EVAL-AD5570EBZ 功能描述:BOARD EVALUATION FOR AD5570 RoHS:是 类别:编程器,开发系统 >> 评估板 - 数模转换器 (DAC) 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:1 系列:- DAC 的数量:4 位数:12 采样率(每秒):- 数据接口:串行,SPI? 设置时间:3µs DAC 型:电流/电压 工作温度:-40°C ~ 85°C 已供物品:板 已用 IC / 零件:MAX5581
EVAL-AD5570SDZ 功能描述:BOARD EVAL FOR AD5570 RoHS:是 类别:编程器,开发系统 >> 评估板 - 数模转换器 (DAC) 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:1 系列:- DAC 的数量:4 位数:12 采样率(每秒):- 数据接口:串行,SPI? 设置时间:3µs DAC 型:电流/电压 工作温度:-40°C ~ 85°C 已供物品:板 已用 IC / 零件:MAX5581
EVAL-AD5590EBZ 功能描述:BOARD EVAL FOR AD5590 RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件
EVAL-AD5620EB 制造商:AD 制造商全称:Analog Devices 功能描述:Single, 12-/14-/16-Bit nanoDAC with 5 ppm/C On-Chip Reference in SOT-23