Rev. 0 | Page 19 of 44
STATUS REGISTER
(RS2, RS1, RS0 = 0, 0, 0; Power-On/Reset = 0x80)
The status register is an 8-bit read-only register. To access the ADC status register, the user must write to the communications register,
select the next operation to be a read, and load Bit RS2, Bit RS1, and Bit RS0 with 0. Table 21 outlines the bit designations for the status
register. SR0 through SR7 indicate the bit locations, SR denoting that the bits are in the status register. SR7 denotes the first bit of the data
stream. The number in parentheses indicates the power-on/reset default status of that bit.
SR7
SR6
SR5
SR4
SR3
SR2
SR1
SR0
RDY(1)
ERR(0)
NOREF(0)
PARITY(0)
0
CHD2(0)
CHD1(0)
CHD0(0)
Table 21. Status Register Bit Designations
Bit Location
Bit Name
Description
SR7
RDY
Ready bit for the ADC. This bit is cleared when data is written to the ADC data register. The RDY bit is set
automatically after the ADC data register is read, or a period of time before the data register is updated,
with a new conversion result to indicate to the user that the conversion data should not be read. It is also
set when the part is placed in power-down mode or idle mode or when SYNC is taken low. The end of a
conversion is also indicated by the DOUT/RDY pin. This pin can be used as an alternative to the status
register for monitoring the ADC for conversion data.
SR6
ERR
ADC error bit. This bit is written to at the same time as the RDY bit. This bit is set to indicate that the result
written to the ADC data register is clamped to all 0s or all 1s. Error sources include overrange or under-
range, or the absence of a reference voltage. This bit is cleared when the result written to the data register
is within the allowed analog input range again.
SR5
NOREF
No external reference bit. This bit is set to indicate that the reference is at a voltage that is below a specified
threshold. When set, conversion results are clamped to all 1s. This bit is cleared to indicate that a valid
reference is applied to the selected reference pins. The NOREF bit is enabled by setting the REFDET bit in
the configuration register to 1.
SR4
PARITY
Parity check of the data register. If the ENPAR bit in the mode register is set, the PARITY bit is set if there is
an odd number of 1s in the data register. It is cleared if there is an even number of 1s in the data register.
The DAT_STA bit in the mode register should be set when the parity check is used. When the DAT_STA bit is
set, the contents of the status register are transmitted along with the data for each data register read.
SR3
0
This bit is set to 0.
SR2 to SR0
CHD2 to
CHD0
These bits indicate which channel corresponds to the data register contents. They do not indicate which
channel is presently being converted but indicate which channel was selected when the conversion
contained in the data register was generated.
MODE REGISTER
(RS2, RS1, RS0 = 0, 0, 1; Power-On/Reset = 0x080060)
The mode register is a 24-bit register from which data can be read or to which data can be written. This register is used to select the
operating mode, the output data rate, and the clock source. Table 22 outlines the bit designations for the mode register. MR0 through
MR23 indicate the bit locations, MR denoting that the bits are in the mode register. MR23 denotes the first bit of the data stream. The
number in parentheses indicates the power-on/reset default status of that bit. Any write to the mode register resets the modulator and
filter and sets the RDY bit.
MR23
MR22
MR21
MR20
MR19
MR18
MR17
MR16
MD2(0)
MD1(0)
MD0(0)
DAT_STA(0)
CLK1(1)
CLK0(0)
0
MR15
MR14
MR13
MR12
MR11
MR10
MR9
MR8
SINC3(0)
0
ENPAR(0)
0
SINGLE(0)
REJ60(0)
FS9(0)
FS8(0)
MR7
MR6
MR5
MR4
MR3
MR2
MR1
MR0
FS7(0)
FS6(1)
FS5(1)
FS4(0)
FS3(0)
FS2(0)
FS1(0)
FS0(0)
相关PDF资料
PDF描述
VI-B6B-EX CONVERTER MOD DC/DC 95V 75W
ECM18DRPI CONN EDGECARD 36POS DIP .156 SLD
EEM25DRMT CONN EDGECARD 50POS .156 WW
V24C8C100BG3 CONVERTER MOD DC/DC 8V 100W
H1WXH-2636G IDC CABLE - HPL26H/AE26G/X
相关代理商/技术参数
参数描述
EVAL-AD7262EDZ 功能描述:BOARD EVAL CONTROL AD7262 RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件
EVAL-AD7264EDZ 功能描述:BOARD EVALUATION FOR AD7264 RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件
EVAL-AD7265CB 制造商:AD 制造商全称:Analog Devices 功能描述:Differential/Single-Ended Input, Dual 1 MSPS, 12-Bit, 3-Channel SAR ADC
EVAL-AD7265CB1 制造商:AD 制造商全称:Analog Devices 功能描述:Differential Input, Dual 1 MSPS, 12-Bit, 3-Channel SAR ADC
EVAL-AD7265EDZ 功能描述:BOARD EVAL FOR AD7265 A/D CONV RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件