MULTICAST-SETUP
This command is used to load the 82596 with the Multicast-IDs that should be accepted. As noted previously,
the filtering done on the Multicast-IDs is not perfect and some unwanted frames may be accepted. This
command resets the current filter and reloads it with the specified Multicast-IDs. The format of the Multicast-
addresses setup command is:
31
16
ODD WORD
15
0
EVEN WORD
EL S
I
X
X
X
X
X
X
X
X
X
X
0
1
1
C
B OK A
0
0
0
0
0
0
0
0
0
0
0
0
X
X
MC COUNT
A15
A0
LINK OFFSET
4th byte
1st byte
MULTICAST ADDRESSES LIST
Nth byte
Figure 26. MC SetupD82586 and 32-Bit Segmented Modes
31
16
ODD WORD
15
0
EVEN WORD
EL S
I
0
0
0
0
0
0
0
0
0
0
0
1
1
C
B OK A
0
0
0
0
0
0
0
0
0
0
0
0
A31
A0
LINK ADDRESS
2nd byte
1st byte X
X
MC COUNT
MULTICAST ADDRESSES LIST
Nth byte
Figure 27. MC SetupDLinear Mode
where:
LINK ADDRESS,
EL, B, C, I, S
D As per standard Command Block (see the NOP command for details)
A
D Indicates that the command was abnormally terminated due to a CU Abort control
command. If one, then the command was aborted and if necessary it should be
repeated. If this bit is zero, the command was not aborted.
Bits 19–28
D Reserved (0 in both the 32-Bit Segmented and Linear Modes).
CMD (bits 16–18)
D The MC SETUP command value: 3h.
MC-CNT
This 14-bit field indicates the number of bytes in the MC LIST field. The MC CNT
must be a multiple of the ADDR LEN; otherwise, the 82596 reduces the MC CNT to
the nearest ADDR LEN multiple. MC CNT
e
0 implies resetting the Hash table
which is equivalent to disabling the Multicast filtering mechanism.
MC LIST
D A list of Multicast Addresses to be accepted by the 82596. The least significant bit
of each MC address must be 1.
NOTE:
The list is sequential; i.e., the most significant byte of an address is immediately followed by the least signifi-
cant byte of the next address.
D When the 82596 is configured to recognize multiple Individual Address (Multi-IA),
the MC-Setup command is also used to set up the Hash table for the individual
address.
The least significant bit in the first byte of each IA address must be 0.
43
相关PDF资料
PDF描述
A8RLRP SENSITIVE GATE TRACS
A921CY-4R7M 1.2A, 24V, 1.4MHz Step-Down Converter in a TSOT23-6
AA108 Circular Connector; MIL SPEC:MIL-C-5015; Body Material:Metal; Series:GT; No. of Contacts:6; Connector Shell Size:36; Connecting Termination:Solder; Circular Shell Style:Straight Plug; Body Style:Straight
AA118 JEDEC DO-7 PACKAGE
AA111 SCRs .5 A, Planar
相关代理商/技术参数
参数描述
A82596SX-16 制造商:未知厂家 制造商全称:未知厂家 功能描述:LAN Node Controller
A82596SX-20 制造商:未知厂家 制造商全称:未知厂家 功能描述:LAN Node Controller
A825ERW 制造商:MPD 制造商全称:MicroPower Direct, LLC 功能描述:Low Cost, 8W DIP Wide Input Range DC/DC Converters
A826 功能描述:Hand Crimper Tool Side Entry 制造商:astro tool corp 系列:- 零件状态:有效 工具类型:手动压接器 配套使用产品/相关产品:- 特性:侧面插入 标准包装:1
A82627-000 制造商:TE Connectivity 功能描述:Shrink Boot Adapters 180° 37/20 Shell Size Cadmium Over Electroless Nickel Aluminum Alloy 制造商:TE Connectivity 功能描述:TX54AB00-2014-CS8117 - Bulk