参数资料
型号: CS80C286-16
厂商: Intersil
文件页数: 24/60页
文件大小: 0K
描述: IC CPU 16BIT 5V 16MHZ 68-PLCC
标准包装: 126
处理器类型: 80C286 16-位
速度: 16MHz
电压: 5V
安装类型: 表面贴装
封装/外壳: 68-LCC(J 形引线)
供应商设备封装: 68-PLCC(24.23x24.23)
包装: 管件
30
Bus Cycle Termination
At maximum transfer rates, the 80C286 bus alternates
between the status and command states. The bus status
signals become inactive after TS so that they may correctly
signal the start of the next bus operation after the completion
of the current cycle. No external indication of TC exists on
the 80C286 local bus. The bus master and bus controller
enter TC directly after TS and continue executing TC cycles
until terminated by the assertion of READY.
READY Operation
The current bus master and 82C288 bus controller terminate
each bus operation simultaneously to achieve maximum bus
operation bandwidth. Both are informed in advance by
READY active (open-collector output from 82C284) which
identifies the last TC cycle of the current bus operation. The
bus master and bus controller must see the same sense of
the READY signal, thereby requiring READY to be synchro-
nous to the system clock.
Synchronous Ready
The 82C284 clock generator provides READY synchroniza-
tion from both synchronous and asynchronous sources (see
Figure 24). The synchronous ready input (SRDY) of the
clock generator is sampled with the falling edge of CLK at
the end of phase 1 of each TC. The state of SRDY is then
broadcast to the bus master and bus controller via the
READY output line.
Asynchronous Ready
Many systems have devices or subsystems that are asyn-
chronous to the system clock. As a result, their ready out-
puts cannot be guaranteed to meet the 82C284 SRDY setup
and hold time requirements. But the 82C284 asynchronous
ready input (ARDY) is designed to accept such signals. The
ARDY input is sampled at the beginning of each TC cycle by
82C284 synchronization logic. This provides one system
CLK cycle time to resolve its value before broadcasting it to
the bus master and bus controller.
ARDY or ARDYEN must be HIGH at the end of TS. ARDY
cannot be used to terminate the bus cycle with no wait
states.
Each ready input of the 82C284 has an enable pin
(SRDYEN and ARDYEN) to select whether the current bus
operation will be terminated by the synchronous or asyn-
chronous ready. Either of the ready inputs may terminate a
bus operation. These enable inputs are active low and have
the same timing as their respective ready inputs. Address
decode logic usually selects whether the current bus opera-
tion should be terminated by ARDY or SRDY.
FIGURE 23. CMDLY CONTROLS THE LEADING EDGE OF COMMAND SIGNAL
TS
TC
TS
TC
READ CYCLE N -1
READ CYCLE N
VALID ADDR N
VALID ADDR (N-1)
A23 - A0
PROC
CLK
S1
S0
ALE
READY
RD
CMDLY
RD
CMDLY
EX1
EX2
φ1
φ2
φ1
φ2
φ1
φ2
φ1
φ2
φ1
φ2
80C286
相关PDF资料
PDF描述
ACB90DHAR CONN EDGECARD 180PS R/A .050 DIP
MPC857TZQ66B IC MPU PWRQUICC 66MHZ 357-PBGA
ABB95DHAS CONN EDGECARD 190PS R/A .050 SLD
MPC857TVR66B IC MPU POWERQUICC 66MHZ 357-PBGA
MPC8271ZQTIEA IC MPU POWERQUICC II 516-PBGA
相关代理商/技术参数
参数描述
CS80C286-1696 制造商:Rochester Electronics LLC 功能描述:- Bulk
CS80C286-2 制造商:Harris Corporation 功能描述:
CS80C286-20 制造商:Rochester Electronics LLC 功能描述:- Bulk
CS80C286-2096 制造商:Rochester Electronics LLC 功能描述:- Bulk
CS80C286-20S2463 制造商:Rochester Electronics LLC 功能描述:- Bulk