24. When ready to receive, Place the TRC105 in synthesizer mode by setting MCFG00 bits 7..5 set to 010.
Monitor the TRC105 Pin 23 to confirm PLL lock.
25. Switch from synthesizer mode to receive mode by setting MCFG00 bits 7..5 to 011.
26. Monitor IRQ0. When an error free packet is received addressed to this node, IRQ0 will set.
27. Switch the TRC105 to standby mode by setting MCFG00 bits 7..5 to 001.
28. Set bit 6 to 1 in PKTCFG1F to enable FIFO read in standby mode.
29. Retrieve the received data from the FIFO through the SPI port.
30. From standby mode, enter another transmit cycle as outlined in steps 20 through 23, or enter
another receive cycle as outlined in steps 24 through 30.
6.7 Battery Power Management Configuration Values
Battery life can be greatly extended in TRC105 applications where transmissions from field nodes are infrequent,
or network communications can be concentrated into periodic time slots. For example, field nodes in many wire-
less alarm systems report operational status a few times a day, and can otherwise sleep unless an alarm condi-
tion occurs. Sensor networks that monitor parameters that change relatively slowly, such as air and soil tempera-
ture in agricultural settings, only need to transmit updates a few times an hour.
At room temperature the TRC105 draws a maximum of 1 μA in sleep mode, with a typical value of 100 nA. To
achieve minimum sleep mode current, nSS_CONFIG (Pin 14), SDI (Pin 17) and SCK (Pin 18) must be held logic
low, while nSS_DATA (Pin 15) must be held logic high. Also, the external connection to SDO (Pin 16) must be
configured as high impedance (tri-state or input). The TRC105 can go from sleep mode through standby mode
and synthesizer mode to transmit (or receive) mode in less than 6 ms. At a data rate of 33.33 kb/s, a 32 byte
packet with a 4 byte preamble and a 4 byte start pattern takes about 10 ms to transmit. Assume that the TRC105
then switches to receive mode for 1 second to listen for a response and returns to sleep. On the basis of reporting
every six hours, the ON to sleep duty cycle is about 1:21,259, greatly extending battery life over continuous
transmit-receive or even standby operation. RFM provides an Excel spreadsheet, battery_ life_ calculator.xls, in
the Application Notes section of www.RFM.com to support battery life for various operating scenarios.
The required timing accuracy for the microcontrollers in a sleep-cycled application depends on several things:
?
?
?
The required “time - stamp” accuracy of data reported by sleeping field nodes. R -C sleep mode timers built
into many microcontrollers have a tolerance of ±20% or more. Where more accurate time stamping is re-
quired, many microcontrollers can run on a watch crystal during sleep and achieve time stamp accuracies
better than 1 second per 24 hours.
If the base station and any routing nodes present in a network must sleep cycle in addition to the field
nodes, watch crystal control will usually be needed to keep all nodes accurately synchronized to the ac-
tive time slots.
If the base station and any routing nodes present in a network can operate continuously (AC powered,
solar charged batteries, etc.) and a loose time stamp accuracy is OK, the microcontrollers in sleeping field
nodes can usually operated from internal low-accuracy R-C timers.
NOTE: The host microcontroller usually cannot be operated from the TRC105 buffered clock output if sleep cy-
cling is planned. In sleep mode, the TRC105 buffered clock output is disabled, which will disable the microcontrol-
ler unless it is capable of automatically switching to an internal clock source when external clocking is lost.
TRC105 sleep related mode switching is configured in MCFG00 bits 7..5 as follows:
www.RFM.com E-mail: info@rfm.com
? 2009-2013 by RF Monolithics, Inc.
Technical support +1.800.704.6079
Page 63 of 67
TRC105 - 05/29/13
相关PDF资料
PDF描述
DR-TXC100-433 BOARD EVALUATION 433MHZ TXC100
DR-WLS1273L-EV KIT EVAL FOR WLS1273L
DR7000-DK 3G DEVELOPMENT KIT 433.92MHZ
DR7001-DK 3G DEVELOPMENT KIT 315 MHZ
DR7003-DK 3G DEVELOPMENT KIT 303.825 MHZ
相关代理商/技术参数
参数描述
DRTU06D06 功能描述:时间延迟和计时继电器 180-240VAC/DC 1-60VDC 6A RoHS:否 制造商:Crydom 显示器类型:Hand Dial 电源电压:280 VAC 定时范围: 触点形式: 触点额定值:6 A 端接类型:DIN Rail
DRTU24A06 功能描述:时间延迟和计时继电器 180-240VAC/DC 24-280VAC 6A RoHS:否 制造商:Crydom 显示器类型:Hand Dial 电源电压:280 VAC 定时范围: 触点形式: 触点额定值:6 A 端接类型:DIN Rail
DRTU24A06R 功能描述:时间延迟和计时继电器 90-140VAC/DC 24-280VAC 6A RoHS:否 制造商:Crydom 显示器类型:Hand Dial 电源电压:280 VAC 定时范围: 触点形式: 触点额定值:6 A 端接类型:DIN Rail
DRTU24B06 功能描述:时间延迟和计时继电器 90-140VAC/DC 24-280VAC 6A RoHS:否 制造商:Crydom 显示器类型:Hand Dial 电源电压:280 VAC 定时范围: 触点形式: 触点额定值:6 A 端接类型:DIN Rail
DRTU24B06R 功能描述:时间延迟和计时继电器 2-24VAC/DC 24-280VAC 6A RoHS:否 制造商:Crydom 显示器类型:Hand Dial 电源电压:280 VAC 定时范围: 触点形式: 触点额定值:6 A 端接类型:DIN Rail