AD7280A
AUXILIARY ADC INPUTS
AD7280A
The AD7280A provides six single-ended analog inputs to the
ADC—AUX1 to AUX6—which can be used to convert the
voltage output of a thermistor temperature measurement circuit.
In the event that no temperature measurements are required or
that individual cell temperature measurements are not required,
the auxiliary ADC inputs can be used to convert any other 0 V
to 5 V input signal.
V SS
AUX TERM
AUX1
AUX2
AUX3
AUX4
AUX5
R TERM
The AD7280A can be programmed to complete conversions on
all six auxiliary ADC channels, on three auxiliary ADC channels
V REG
AUX6
(AUX1, AUX3, and AUX5), or on none of the auxiliary ADC
input channels. The number of conversions is programmed
through Bits[D15:D14] of the control register. The number of
conversion results supplied by the AD7280A for readback by
the DSP/microprocessor is programmed through Bits[D13:D12]
of the control register. It is also possible to read back a single
auxiliary ADC conversion result from each device in the daisy
Figure 36. Typical Circuit Using the Thermistor Termination Resistor
POWER REQUIREMENTS
The current consumed by the AD7280A in normal operation,
that is, when not in power-down mode, is dependent on the
mode in which the part is being operated. The three distinct
modes of operation can be described as follows:
chain. This can be done by programming the read register on
each device to read back the required conversion result (see
section). If the device is used in this mode, the overall conversion
?
?
?
Voltage and auxiliary ADC input conversion
AD7280A configuration and data readback
Cell balancing
sample rate should be limited by the conversion window required
for the number of channels selected by Bits[D15:D14] of the
control register.
In an application where the alert function is used but only one
or two auxiliary ADC inputs are required, the AD7280A should
first be programmed to complete and read back only three
auxiliary ADC conversions by setting Bits[D15:D12] of the
control register to 0101. Channel AUX5 and Channel AUX3 can
be removed from the alert detection by writing to Bits[D1:D0]
of the alert register (see Table 12 in the Alert Output section).
Thermistor Termination Input
If thermistor circuits are used to measure each individual cell
temperature, the thermistor termination pin, AUX TERM , can be
used to terminate the thermistor inputs for each auxiliary ADC
input measurement. This reduces the termination resistor
requirement from six resistors to one. Bit D3 in the control
register should be set to 1 when using the AUX TERM input.
Note that, due to settling time requirements, the thermistor termi-
nation resistor option should only be used when the acquisition
time of the AD7280A is set to its highest value (1.6 μs). The
acquisition time is configured by setting Bits[D6:D5] of the
control register (see Table 9).
In Figure 36, the termination resistor is placed between V SS
The AD7280A consumes its highest level of current while con-
verting voltage and/or auxiliary ADC inputs to digital outputs.
Depending on the configuration of the AD7280A, the conversion
time can be as little as 6 μs. The typical current required by the
AD7280A during conversion is 6.9 mA (see Table 2).
When configuring a chain of AD7280As or when reading back
the voltage and/or auxiliary ADC conversion results from a chain
of AD7280As, the current required for each AD7280A is typically
6.5 mA (see Table 2). The time required to read back the voltage
conversions results from 48 lithium ion cells depends on the
speed of the interface clock used, that is, SCLK, but it can be as
low as 1.54 ms.
The typical current consumed by the AD7280A when the cell
balance outputs are switched on is 6.4 mA (see Table 2). The
length of time for which the cell balance outputs are switched
on is defined by the user.
When the AD7280A is not being used in any of the aforemen-
tioned modes of operation, it is recommended that the device
be powered down, as described in the Power-Down section.
This significantly reduces the current drawn by each AD7280A
in the chain, which avoids unnecessary draining of the lithium
ion cells and aids in current matching between devices across
the full battery stack.
and AUX TERM . The AUX TERM input can be used to terminate the
thermistor inputs to the high or low voltage of the thermistor
circuit.
Rev. 0 | Page 23 of 48
相关PDF资料
PDF描述
V110C24C100B3 CONVERTER MOD DC/DC 24V 100W
MLG0603S2N0S INDUCTOR MULTILAYER 2.0NH 0201
V110C24C100B2 CONVERTER MOD DC/DC 24V 100W
EVAL-ADM1087EB BOARD EVAL FOR ADM1087
V110B28E150BG2 CONVERTER MOD DC/DC 28V 150W
相关代理商/技术参数
参数描述
EVAL-AD7291SDZ 功能描述:BOARD EVAL FOR AD7291 RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件
EVAL-AD7292SDZ 功能描述:数据转换 IC 开发工具 EVALUATION BOARD RoHS:否 制造商:Texas Instruments 产品:Demonstration Kits 类型:ADC 工具用于评估:ADS130E08 接口类型:SPI 工作电源电压:- 6 V to + 6 V
EVAL-AD7294EBZ 功能描述:BOARD EVALUATION FOR AD7294 RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件
EVAL-AD7298SDZ 功能描述:BOARD EVAL FOR AD7298 RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件
EVAL-AD7298SDZ 制造商:Analog Devices 功能描述:EVAL BOARD, AD7192 12BIT ADC