4–18
Chapter 4: Functional Description
Multiple Core Configuration
Figure 4–17 shows what happens when the SerialLite II MegaCore function is
initialized.
Figure 4–17. Initialization
mreset_n
stat_tc_pll_locked
stat_rr_freqlock
stat_tc_rst_done
stat_rr_link
When the reset_n input signal is asserted, the transceiver and the MegaCore function
start to reset and initialize the MegaCore function. When the corresponding signals,
stat_tc_pll_locked , stat_rr_freqlock , and the stat_tc_rst_done signal go high, a
set of training sequence are transmitted across the link to align the characters and
lanes. When everything is synchronized, the link is established and ready to be used,
stat_rr_link = 1.
Multiple Core Configuration
When you instantiate multiple SerialLite II MegaCore functions, you must apply the
following additional guidelines to create a working design.
SerialLite II MegaCore Function
User Guide
If you use the Tcl constraints to make assignments for the MegaCore functions,
you must edit the Tcl script associated with each generated SerialLite II MegaCore
function to update the hierarchal paths to each clock node and signal inside the
TCL scripts. You can use the generated scripts as a guide. You must also make
these changes to the generated Synopsys Design Constraints File ( .sdc ) if you
intend to use the TimeQuest Timing Analyzer.
Note that the Tcl scripts assume a top-level name for several clocks, such as:
trefclk , rxrdp_clk , rxhpp_clk , txrdp_clk , and txhpp_clk . You must edit Set
Clock Names in the scripts if the clock name connected to these inputs does not
match. If the multiple cores are connected to the same clocks at the top-level file,
you must make sure Set Clock Names and clock settings are only available in
one script. You must always set to run this script first in the projects. You must edit
the Tcl script and the .sdc file if you plan to use the TimeQuest timing analyzer.
For Arria II GX and Stratix IV designs, you must ensure that the cal_blk_clk
input to each SerialLite II MegaCore function is driven by the same calibration
clock source. In addition, ensure that the SerialLite II MegaCore function and other
MegaCore variants in the system that use the ALTGX megafunction have the same
clock source connected to their respective cal_blk_clk ports.
In Arria II GX and Stratix IV designs that include multiple SerialLite II cores in a
single transceiver block, the same signal must drive gxb_powerdown to each of the
SerialLite II MegaCore variants.
January 2014 Altera Corporation
相关PDF资料
PDF描述
IP-SRAM/QDRII IP QDRII SRAM CONTROLLER
IP-VITERBI/SS IP VITERBI LOW-SPEED
IP4220CZ6,125 IC USB DUAL ESD PROTECT 6TSOP
IPA-66-1-600-10.0-A-01-T CIRC BRKR 10A 2POLE SCREW TERM
IPR-CSC IP COLOR SPACE CONVERTER RENEW
相关代理商/技术参数
参数描述
IPSLU-AP005-5 功能描述:Pressure Sensor 15 PSI (103.42 kPa) Absolute Male - 1/4" (6.35mm) NPT 4 mA ~ 20 mA Probe 制造商:cynergy 3 系列:IPSLU 零件状态:有效 压力类型:绝对 工作压力:15 PSI(103.42 kPa) 输出类型:模拟电流 输出:4 mA ~ 20 mA 精度:±0.5% 电压 - 电源:9 V ~ 32 V 端口尺寸:公型 - 1/4"(6.35mm) NPT 端口样式:有螺纹 特性:放大输出,温度补偿 端子类型:连接器 最高压力:- 工作温度:-20°C ~ 80°C 封装/外壳:探头组件 供应商器件封装:探头组件 标准包装:1
IPSLU-AP010-5 功能描述:Pressure Sensor 10 PSI (68.95 kPa) Absolute Male - 1/4" (6.35mm) NPT 4 mA ~ 20 mA Probe 制造商:cynergy 3 系列:IPSLU 零件状态:有效 压力类型:绝对 工作压力:10 PSI(68.95 kPa) 输出类型:模拟电流 输出:4 mA ~ 20 mA 精度:±0.5% 电压 - 电源:9 V ~ 32 V 端口尺寸:公型 - 1/4"(6.35mm) NPT 端口样式:有螺纹 特性:放大输出,温度补偿 端子类型:连接器 最高压力:- 工作温度:-20°C ~ 80°C 封装/外壳:探头组件 供应商器件封装:探头组件 标准包装:1
IPSLU-AP015-5 功能描述:Pressure Sensor 15 PSI (103.42 kPa) Absolute Male - 1/4" (6.35mm) NPT 4 mA ~ 20 mA Probe 制造商:cynergy 3 系列:IPSLU 零件状态:有效 压力类型:绝对 工作压力:15 PSI(103.42 kPa) 输出类型:模拟电流 输出:4 mA ~ 20 mA 精度:±0.5% 电压 - 电源:9 V ~ 32 V 端口尺寸:公型 - 1/4"(6.35mm) NPT 端口样式:有螺纹 特性:放大输出,温度补偿 端子类型:连接器 最高压力:- 工作温度:-20°C ~ 80°C 封装/外壳:探头组件 供应商器件封装:探头组件 标准包装:1
IPSLUAT-AP005-5 功能描述:Pressure Sensor 5 PSI (34.47 kPa) Absolute Male - 1/4" (6.35mm) NPT 4 mA ~ 20 mA Cylinder, Threaded 制造商:cynergy 3 系列:IPSLU 零件状态:有效 压力类型:绝对 工作压力:5 PSI(34.47 kPa) 输出类型:模拟电流 输出:4 mA ~ 20 mA 精度:±0.5% 电压 - 电源:9 V ~ 32 V 端口尺寸:公型 - 1/4"(6.35mm) NPT 端口样式:有螺纹 特性:放大输出,温度补偿 端子类型:连接器 最高压力:75 PSI(517.11 kPa) 工作温度:-20°C ~ 80°C 封装/外壳:圆柱形,有螺纹 供应商器件封装:* 标准包装:1
IPSLUAT-AP010-5 功能描述:Pressure Sensor 10 PSI (68.95 kPa) Absolute Male - 1/4" (6.35mm) NPT 4 mA ~ 20 mA Cylinder, Threaded 制造商:cynergy 3 系列:IPSLU 零件状态:有效 压力类型:绝对 工作压力:10 PSI(68.95 kPa) 输出类型:模拟电流 输出:4 mA ~ 20 mA 精度:±0.5% 电压 - 电源:9 V ~ 32 V 端口尺寸:公型 - 1/4"(6.35mm) NPT 端口样式:有螺纹 特性:放大输出,温度补偿 端子类型:连接器 最高压力:75 PSI(517.11 kPa) 工作温度:-20°C ~ 80°C 封装/外壳:圆柱形,有螺纹 供应商器件封装:* 标准包装:1