SPI slave mode operation in LF2403A
The LF2403A device does not have the SPISTE/IOPC5 pin. (This function is available as an internal signal only.)
The following must be done to put the LF2403A SPI in slave mode:
1. Configure SPISTE/IOPC5 signal for GPIO mode by clearing the MCRB.5 bit.
2. Configure SPISTE/IOPC5 signal as an output (by writing a 1 to bit 13 of PCDATDIR) and drive it low (by
writing a 0 to bit 5 of PCDATDIR). Note that SPISTE/IOPC5 should not be driven low until after the SPI is
configured and taken out of reset.
NOTE: The slave SPISTE/IOPC5 signal must not be driven low until after the master and slave SPI modules
are configured and taken out of reset. The initialization sequence is as follows:
a. The master SPI is configured first and taken out of reset. This ensures that the master SPICLK is
initialized to its appropriate level (high or low, depending on the polarity bit) first, before the slave SPI
starts accepting clock pulses.
b. The slave SPI is configured and taken out of reset.
c. The GPIO/SPI pins of the slave is then configured for SPI operation and the SPISTE/IOPC5 signal is
driven low. This is done after ensuring the correct level of the master SPICLK signal. One method of
doing this would be to read the level of the SPICLK pin through the PCDATDIR register and then
deciding on the appropriate course of action.
d. SPI transmission may commence now. Transmission of data should not be attempted until both master
and slave are configured and the slave SPISTE/IOPC5 signal is driven low.
PLL-based clock module
The 240xA has an on-chip, PLL-based clock module. This module provides all the necessary clocking signals
for the device, as well as control for low-power mode entry. The PLL has a 3-bit ratio control to select different
CPU clock rates. See Figure 16 for the PLL Clock Module Block Diagram, Table 9 for clock rates, and Table 10
for the loop filter component values.
The PLL-based clock module provides two modes of operation:
D Crystal-operation
This mode allows the use of an external crystal/resonator to provide the time base to the device.
D External clock source operation
This mode allows the internal oscillator to be bypassed. The device clocks are generated from an external
clock source input on the XTAL1/CLKIN pin. In this case, an external oscillator clock is connected to the
XTAL1/CLKIN pin.
相关PDF资料
PDF描述
TMX320LF2404APAGA DSP CONTROLLERS
TMX320LF2404APAGS DSP CONTROLLERS
TMX320LF2404APGA DSP CONTROLLERS
TMX320LF2404APGEA DSP CONTROLLERS
TMX320LF2404APGES DSP CONTROLLERS
相关代理商/技术参数
参数描述
TMX320LF2404APAGA 制造商:TI 制造商全称:Texas Instruments 功能描述:DSP CONTROLLERS
TMX320LF2404APAGS 制造商:TI 制造商全称:Texas Instruments 功能描述:DSP CONTROLLERS
TMX320LF2404APGA 制造商:TI 制造商全称:Texas Instruments 功能描述:DSP CONTROLLERS
TMX320LF2404APGEA 制造商:TI 制造商全称:Texas Instruments 功能描述:DSP CONTROLLERS
TMX320LF2404APGES 制造商:TI 制造商全称:Texas Instruments 功能描述:DSP CONTROLLERS