型号: XR16C2852IJTR-F
厂商: Exar Corporation
文件页数: 25/51页
文件大小: 0K
描述: IC UART FIFO 128B 44PLCC
标准包装: 500
特点: *
通道数: 2,DUART
FIFO's: 128 字节
规程: RS232,RS485
电源电压: 2.97 V ~ 5.5 V
带自动流量控制功能:
带IrDA 编码器/解码器:
带故障启动位检测功能:
带调制解调器控制功能:
带CMOS:
安装类型: 表面贴装
封装/外壳: 44-LCC(J 形引线)
供应商设备封装: 44-PLCC(16.59x16.59)
包装: 带卷 (TR)
xr
XR16C2852
REV. 2.1.1
2.97V TO 5.5V DUAL UART WITH 128-BYTE FIFOS
31
MCR[6]: Infrared Encoder/Decoder Enable
Logic 0 = Enable the standard modem receive and transmit input/output interface (default).
Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the
infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface
requirement. While in this mode, the infrared TX output will be LOW during idle data conditions.
MCR[7]: Clock Prescaler Select
Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable
Baud Rate Generator without further modification, i.e., divide by one (default).
Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and
feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth.
4.9
Line Status Register (LSR) - Read Only
This register provides the status of data transfers between the UART and the host.
LSR[0]: Receive Data Ready Indicator
Logic 0 = No data in receive holding register or FIFO (default).
Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
LSR[1]: Receiver Overrun Flag
Logic 0 = No overrun error. (default)
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register
is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into
the FIFO, therefore the data in the FIFO is not corrupted by the error.
LSR[2]: Receive Data Parity Error Flag
Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
LSR[3]: Receive Data Framing Error Flag
Logic 0 = No framing error (default).
Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
LSR[4]: Receive Break Flag
Logic 0 = No break condition (default).
Logic 1 = The receiver received a break signal (RX was LOW for at least one character frame time). In the
FIFO mode, only one break character is loaded into the FIFO. The break indication remains until the RX
input returns to the idle condition, “mark” or HIGH.
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte
is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0
concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set
when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte.
LSR[6]: THR and TSR Empty Flag
This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or
TSR contains a data character. In the FIFO mode this bit is set to a logic 1 whenever the transmit FIFO and
transmit shift register are both empty.
相关PDF资料
PDF描述
XR16C2850IJTR-F IC UART FIFO 128B 44PLCC
XR16V554IV-F IC UART FIFO 16B QUAD 64LQFP
VE-B5L-IW-F1 CONVERTER MOD DC/DC 28V 100W
VE-B5L-IX-F4 CONVERTER MOD DC/DC 28V 75W
VE-B5L-IX-F2 CONVERTER MOD DC/DC 28V 75W