参数资料
型号: ADE7753ARSZ
厂商: Analog Devices Inc
文件页数: 33/60页
文件大小: 0K
描述: IC ENERGY METERING 1PHASE 20SSOP
标准包装: 66
输入阻抗: 390 千欧
测量误差: 0.1%
电压 - 高输入/输出: 2.4V
电压 - 低输入/输出: 0.8V
电流 - 电源: 3mA
电源电压: 4.75 V ~ 5.25 V
测量仪表类型: 单相
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 20-SSOP(0.209",5.30mm 宽)
供应商设备封装: 20-SSOP
包装: 管件
产品目录页面: 797 (CN2011-ZH PDF)
配用: EVAL-ADE7753ZEB-ND - BOARD EVALUATION AD7753
ADE7753
LINE CYCLE ENERGY ACCUMULATION MODE
In line cycle energy accumulation mode, the energy accumula-
tion of the ADE7753 can be synchronized to the Channel 2 zero
crossing so that active energy can be accumulated over an
integral number of half line cycles. The advantage of summing
the active energy over an integer number of line cycles is that
the sinusoidal component in the active energy is reduced to 0.
This eliminates any ripple in the energy calculation. Energy is
calculated more accurately and in a shorter time because the
integration period can be shortened. By using the line cycle
energy accumulation mode, the energy calibration can be
greatly simplified, and the time required to calibrate the meter
can be significantly reduced. The ADE7753 is placed in line
cycle energy accumulation mode by setting Bit 7 (CYCMODE)
in the mode register. In line cycle energy accumulation mode,
the ADE7753 accumulates the active power signal in the
LAENERGY register (Address 0x04) for an integral number of
line cycles, as shown in Figure 69. The number of half line
cycles is specified in the LINECYC register (Address 0x1C). The
ADE7753 can accumulate active power for up to 65,535 half
line cycles. Because the active power is integrated on an integral
number of line cycles, at the end of a line cycle energy accumu-
lation cycle the CYCEND flag in the interrupt status register is
set (Bit 2). If the CYCEND enable bit in the interrupt enable
register is enabled, the IRQ output also goes active low. Thus the
IRQ line can also be used to signal the completion of the line
cycle energy accumulation. Another calibration cycle can start
as long as the CYCMODE bit in the mode register is set.
From Equations 13 and 18,
Note that in this mode, the 16-bit LINECYC register can hold a
maximum value of 65,535. In other words, the line energy
accumulation mode can be used to accumulate active energy for
a maximum duration over 65,535 half line cycles. At 60 Hz line
frequency, it translates to a total duration of 65,535/120 Hz =
546 seconds.
POSITIVE-ONLY ACCUMULATION MODE
In positive-only accumulation mode, the energy accumulation
is done only for positive power, ignoring any occurrence of
negative power above or below the no-load threshold, as shown
in Figure 70. The CF pulse also reflects this accumulation
method when in this mode. The ADE7753 is placed in positive-
only accumulation mode by setting the MSB of the mode
register (MODE[15]). The default setting for this mode is off.
Transitions in the direction of power flow, going from negative
to positive or positive to negative, set the IRQ pin to active low
if the interrupt enable register is enabled. The interrupt status
registers, PPOS and PNEG, show which transition has
occurred—see the ADE7753 register descriptions in Table 12 .
ACTIVE ENERGY
NO-LOAD
THRESHOLD
? ? nT
VI
? ? f ? ? 0
? 1 + ?
? ?
nT
E ( t ) = ∫ VI dt ? ? 2 ? ∫
0
? ?
? ?
? ? 8 . 9 ? ?
cos (2π ft ) dt
(20)
ACTIVE POWER
NO-LOAD
THRESHOLD
where:
IRQ
PPOS
PNEG
PPOS PNEG PPOS PNEG
n is an integer.
T is the line cycle period.
Since the sinusoidal component is integrated over an integer
number of line cycles, its value is always 0. Therefore,
INTERRUPT STATUS REGISTERS
02875-0-069
Figure 70. Energy Accumulation in Positive-Only Accumulation Mode
NO-LOAD THRESHOLD
E =
nT
∫ VIdt
0
+0
(21)
The ADE7753 includes a no-load threshold feature on the
active energy that eliminates any creep effects in the meter. The
ADE7753 accomplishes this by not accumulating energy if the
E ( t ) = VInT
(22)
multiplier output is below the no-load threshold. This threshold
is 0.001% of the full-scale output frequency of the multiplier.
Compare this value to the IEC1036 specification, which states
that the meter must start up with a load equal to or less than
0.4% Ib. This standard translates to .0167% of the full-scale
output frequency of the multiplier.
REACTIVE POWER CALCULATION
Reactive power is defined as the product of the voltage and
current waveforms when one of these signals is phase-shifted by
Rev. C | Page 33 of 60
相关PDF资料
PDF描述
A7SSB-1506G CABLE D-SUB-AFM15B/AE15G/AFM15B
HMM06DSUS CONN EDGECARD 12POS .156 DIP SLD
GCC10DCAI-S189 CONN EDGECARD 20POS R/A .100 SLD
ADE7759ARSZ IC ENERGY METERING 1PHASE 20SSOP
RMM40DTAD-S189 CONN EDGECARD 80POS R/A .156 SLD
相关代理商/技术参数
参数描述
ADE7753ARSZ 制造商:Analog Devices 功能描述:ENERGY METERING IC
ADE7753ARSZ 制造商:Analog Devices 功能描述:IC MULTIFUNCTION METER
ADE7753ARSZRL 功能描述:IC ENERGY METERING 1PHASE 20SSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7753-ARSZRL 制造商:Analog Devices 功能描述:
ADE7753XRS 制造商:Analog Devices 功能描述: