Data Sheet
DATA TRANSMISSION FAULTS
Data transmission faults occur when two communicating devices
violate the PMBus communication protocol, as specified in the
PMBus specification. See the PMBus specification for more
information about each fault condition.
Corrupted Data, PEC (Item 10.8.1)
Parity error checking. Not supported.
Sending Too Few Bits (Item 10.8.2)
Transmission is interrupted by a start or stop condition before
a complete byte (eight bits) has been sent. Not supported; any
transmitted data is ignored.
ADP1047/ADP1048
DATA CONTENT FAULTS
Data content faults occur when data transmission is successful,
but the PMBus slave device cannot process the data that is
received from the master device.
Improperly Set Read Bit in the Address Byte (Item 10.9.1)
All PMBus commands start with a slave address with the R/W
bit cleared (set to 0), followed by the command code. If a host
starts a PMBus transaction with R/W set in the address phase
(equivalent to an I 2 C read), the PMBus slave considers this a
data content fault and responds as follows:
? ACKs the address byte
Reading Too Few Bits (Item 10.8.3)
Transmission is interrupted by a start or stop condition before
a complete byte (eight bits) has been read. Not supported; any
received data is ignored.
?
?
?
NACKs the command and data bytes
Sends all 1s (0xFF) as long as the host continues to
request data
Sets the CML bit in the STATUS_BYTE register
Host Sends or Reads Too Few Bytes (Item 10.8.4)
If a host ends a packet with a stop condition before the required
bytes are sent/received, it is assumed that the host intended to
stop the transfer. Therefore, the PMBus does not consider this
Invalid or Unsupported Command Code (Item 10.9.2)
If an invalid or unsupported command code is sent to the
PMBus slave, the code is considered to be a data content fault,
and the PMBus slave responds as follows:
to be an error and takes no action, except to flush any remain-
ing bytes in the transmit FIFO.
Host Sends Too Many Bytes (Item 10.8.5)
If a host sends more bytes than are expected for the corres-
?
?
?
NACKs the illegal/unsupported command byte and data
bytes
Flushes and ignores the received command and data
Sets the CML bit in the STATUS_BYTE register
ponding command, the PMBus slave considers this a data
transmission fault and responds as follows:
? NACKs all unexpected bytes as they are received
Reserved Bits (Item 10.9.5)
Accesses to reserved bits are not a fault. Writes to reserved bits
are ignored, and reads from reserved bits return 0.
?
?
Flushes and ignores the received command and data
Sets the CML bit in the STATUS_BYTE register
Write to Read-Only Commands
If a host performs a write to a read-only command, the PMBus
Host Reads Too Many Bytes (Item 10.8.6)
slave considers this a data content fault and responds as follows:
If a host reads more bytes than are expected for the corres-
ponding command, the PMBus slave considers this a data
transmission fault and responds as follows:
?
?
?
NACKs all unexpected data bytes as they are received
Flushes and ignores the received command and data
Sets the CML bit in the STATUS_BYTE register
?
?
Sends all 1s (0xFF) as long as the host continues to
request data
Sets the CML bit in the STATUS_BYTE register
Note that this is the same error described in the Host Sends Too
Read from Write-Only Commands
Device Busy (Item 10.8.7)
The PMBus slave device is too busy to respond to a request
from the master device. Not supported.
If a host performs a read from a write-only command, the
PMBus slave considers this a data content fault and responds
as follows:
?
?
Sends all 1s (0xFF) as long as the host continues to
request data
Sets the CML bit in the STATUS_BYTE register
Note that this is the same error described in the Host Reads Too
Rev. 0 | Page 37 of 84
相关PDF资料
PDF描述
RCB06DHRD CONN CARD EXTEND 12POS .050"
V72A5C300B CONVERTER MOD DC/DC 5V 300W
395-120-520-801 CARD EDGE 120PS DL .100X.200 BLK
T97R686K025LSA CAP TANT 68UF 25V 10% 2824
345-120-540-202 CARDEDGE 120POS DUAL .100 GREEN
相关代理商/技术参数
参数描述
ADP1048DC1-EVALZ 功能描述:DAUGHTERCARD ADP1048 RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:- 标准包装:1 系列:- 主要目的:电信,线路接口单元(LIU) 嵌入式:- 已用 IC / 零件:IDT82V2081 主要属性:T1/J1/E1 LIU 次要属性:- 已供物品:板,电源,线缆,CD 其它名称:82EBV2081
ADP1048WARQZ-R7 功能描述:PFC IC Average Current 30kHz ~ 400kHz 24-QSOP 制造商:analog devices inc. 系列:- 包装:带卷(TR) 零件状态:有效 模式:平均电流 频率 - 开关:30kHz ~ 400kHz 电流 - 启动:- 电压 - 电源:3 V ~ 3.6 V 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:24-SSOP(0.209",5.30mm 宽) 供应商器件封装:24-QSOP 标准包装:1,000
ADP1050ACPZ-R7 功能描述:Power Supply Controller Power Supply Controller/Monitor 20-LFCSP-WQ (4x4) 制造商:analog devices inc. 系列:- 包装:剪切带(CT) 零件状态:有效 应用:电源控制器/监控器 电压 - 输入:0 V ~ 1.6 V 电压 - 电源:3 V ~ 3.6 V 电流 - 电源:28.5mA 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:20-WFQFN 裸露焊盘,CSP 供应商器件封装:20-LFCSP-WQ(4x4) 标准包装:1
ADP1050ACPZ-RL 功能描述:Power Supply Controller Power Supply Controller/Monitor 20-LFCSP-WQ (4x4) 制造商:analog devices inc. 系列:- 包装:带卷(TR) 零件状态:在售 应用:电源控制器/监控器 电压 - 输入:0 V ~ 1.6 V 电压 - 电源:3 V ~ 3.6 V 电流 - 电源:28.5mA 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:20-WFQFN 裸露焊盘,CSP 供应商器件封装:20-LFCSP-WQ(4x4) 标准包装:5,000
ADP1050DC1-EVALZ 功能描述:ADP1050 - Power Management, Digital Power Controller Evaluation Board 制造商:analog devices inc. 系列:- 零件状态:有效 主要用途:电源管理,数字电源控制器 嵌入式:- 使用的 IC/零件:ADP1050 主要属性:- 辅助属性:- 所含物品:板 标准包装:1