参数资料
型号: TRC105
厂商: RFM
文件页数: 48/67页
文件大小: 0K
描述: IC TXRX 300MHZ-510MHZ 32TQFN
标准包装: 1
频率: 300MHz ~ 510MHz
数据传输率 - 最大: 200kbps
调制或协议: FSK,OOK
应用: 通用
功率 - 输出: 13dBm
灵敏度: -112dBm
电源电压: 2.1 V ~ 3.6 V
电流 - 接收: 3mA
电流 - 传输: 30mA
数据接口: PCB,表面贴装
天线连接器: PCB,表面贴装
工作温度: -40°C ~ 85°C
封装/外壳: 32-TQFN
包装: 标准包装
产品目录页面: 583 (CN2011-ZH PDF)
其它名称: 583-1159-6
Where F CBW is the 3 dB bandwidth of the receiver Butterworth filters in kHz and J is the integer value of the bit
pattern in RXCFG10 bits 3..0. Using a standard 12.8 MHz crystal, the equation for determining J is:
J = (F CBW - 25)/25
J must be an integer value, so F CBW is limited to 16 discrete values. If the value of J given in the above equation is
not an integer for your deviation and bit rate, round the value of J down to the nearest integer and use this value
to set the bandwidth of the receiver Butterworth filters for the bit rate you are using. For operation at 133 kb/s and
above, use a value of 15 for J.
The recommended 3 dB bandwidth for the receiver R-C filters is:
F CRC = 3.25*F CBW
Where F CRC and F CBW are in kHz. The bandwidth of F CRC is set by bits 7..4 in RXCFG10 . The relationship of the R-
C filter bandwidth to the integer value in RXCFG10 bits 7..4 is given in Table 59. Where the calculated value for
F CRC falls between table values, use the higher table value. For operation at 100 kb/s and above, use the 987 kHz
R-C filter bandwidth.
Pattern of Bits 7..4
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
R-C Filter Bandwidth
65 kHz
82 kHz
109 kHz
137 kHz
157 kHz
184 kHz
211 kHz
234 kHz
262 kHz
321 kHz
378 kHz
414 kHz
458 kHz
514 kHz
676 kHz
987 kHz
Table 59
6.2.2 Determining Transmitter Power Configuration Values
European ETSI EN 300 220-1 regulates unlicensed radio operation in the 433.05 to 434.97 MHz band. A
transmitter power level up to 10 dBm can be used in this band, subject to certain restrictions. See EN 300 220-1
for details.
FCC Part 15 and Canadian RSS-210 regulate unlicensed radio operation in several bands covered by the
TRC105. The allowed transmitter power level (field strength) depends on the operating frequency and application.
See these documents for details.
The use of the TRC105 is supported by various radio regulations in almost every geographic location in the world.
Please contact RFM’s local Field Application Engineer for additional information.
The relationship of the transmitter power level to the integer value of TXCFG1A bits 3..1 is given in Table 60.
There are eight available power settings (approximate):
www.RFM.com E-mail: info@rfm.com
? 2009-2013 by RF Monolithics, Inc.
Technical support +1.800.704.6079
Page 48 of 67
TRC105 - 05/29/13
相关PDF资料
PDF描述
MT-6-15 XFRMR 115V 5V 1.75A 6VA 3OUT
IF-2-10 XFRMR 115/230V 5V 400MA 2VA PCB
14A-20-515 XFRMR PWR 115/230V 5V 750MA 20VA
14A-20-512 XFRMR PWR 115/230V 5V 750MA 20VA
SI4421-A0-FT IC TXRX FSK 915MHZ 3.8V 16-TSSOP
相关代理商/技术参数
参数描述
TRC1053 制造商:未知厂家 制造商全称:未知厂家 功能描述:10/100M Single Port Transformer Modules
TRC1060 制造商:未知厂家 制造商全称:未知厂家 功能描述:10/100M Single Port Transformer Modules
TRC1062 制造商:未知厂家 制造商全称:未知厂家 功能描述:10/100M Single Port Transformer Modules
TRC1068 制造商:未知厂家 制造商全称:未知厂家 功能描述:10/100M Single Port Transformer Modules
TRC1074 制造商:未知厂家 制造商全称:未知厂家 功能描述:10/100M Single Port Transformer Modules