Functional Description E1
User’s Manual
Hardware Description
101
DS1.1, 2003-10-23
Clock adaption between system clock (SCLKX) and internally generated transmit
route clock (XCLK).
Compensation of input wander and jitter.
Frame alignment between system frame and transmit route frame
Reporting and controlling of slips
Writing of received data from XDI is controlled by SCLKX/R and SYPX/XMFS in
combination with the programmed offset values for the transmit time slot/clock slot
counters. Reading of stored data is controlled by the clock generated by DCO-X circuitry
or the externally generated TCLK and the transmit framer. With the de-jittered clock data
is read from the transmit elastic buffer and are forwarded to the transmitter. Reporting
and controlling of slips is done according to the receive direction. Positive/negative slips
are reported in interrupt status bits ISR4.XSP and ISR4.XSN. If the transmit buffer is
bypassed data is directly transferred to the transmitter.
The following table gives an overview of the transmit buffer operating modes.
4.4.5
Programmable Pulse Shaper (E1)
The analog transmitter includes a programmable pulse shaper to satisfy the
requirements of ITU-T I.431. The amplitude and shape of the transmit pulses are
completely programmable by registers XPM(2:0).
The transmitter requires an external step up transformer to drive the line.
Note: To achieve higher slew rates the pulse undershoot can be programmed in the 3
rd
and 4
th
sub pulse fraction by setting LIM2.EOU and the corresponding bits in
registers XPM (2:0).
4.4.6
Transmit Line Monitor (E1)
The transmit line monitor compares the transmit line current on XL1 and XL2 with an
on-chip transmit line current limiter. The monitor detects faults on the primary side of the
transformer indicated by a highly increased transmit line current (more than 120 mA for
at least 3 consecutive pulses sourced by V
DDX
by setting the transmit line driver XL1/2 into high-impedance state automatically (if
enabled by XPM2.DAXLT = 0). The current limiter checks the actual current value of
1)
) and protects the device from damage
Table 23
SIC1.XBS(1:0)
Transmit Buffer Operating Modes (E1)
Buffer Size
TS Offset
programming
enabled
enabled
enabled
enabled
Slip performance
00
11
01
10
bypass
short buffer
1 frame
2 frames
no
yes
yes