3.5
LOS (Loss of Signal) Detector
3.5.1
DS3/STS-1 LOS Condition
A Digital Loss of SIgnal (DLOS) condition occurs when a string of 175 ± 75 consecutive zeros occur on the line.
When the DLOS condition occurs, the DLOS_n bit is set to “1” in the status control register. DLOS condition is
cleared when the detected average pulse density is greater than 33% for 175 ± 75 pulses. Analog Loss of
Signal (ALOS) condition occurs when the amplitude of the incoming line signal is below the threshold as shown
in the Table 3.The status of the ALOS condition is reflected in the ALOS_n status control register. RLOS is the
logical OR of the DLOS and ALOS states. When the RLOS condition occurs the RLOS_n output pin is toggled
“High” and the RLOS_n bit is set to “1” in the status control register.
3.5.2
Disabling ALOS/DLOS Detection
For debugging purposes it is useful to disable the ALOS and/or DLOS detection. Writing a “1” to both
ALOSDIS_n and DLOSDIS_n bits disables the LOS detection on a per channel basis.
3.5.3
E3 LOS Condition:
If the level of incoming line signal drops below the threshold as described in the ITU-T G.775 standard, the
LOS condition is detected. Loss of signal is defined as no transitions for 10 to 255 consecutive zeros. No
transitions is defined as a signal level between 15 and 35 dB below the normal. This is illustrated in Figure 8.
The LOS condition is cleared within 10 to 255 UI after restoration of the incoming line signal. Figure 9 shows
the LOS declaration and clearance conditions.
TABLE 3: THE ALOS (ANALOG LOS) DECLARATION AND CLEARANCE THRESHOLDS FOR A GIVEN SETTING OF
REQEN (DS3 AND STS-1 APPLICATIONS)
APPLICATION REQEN SETTING
SIGNAL LEVEL TO DECLARE ALOS
DEFECT
SIGNAL LEVEL TO CLEAR ALOS
DEFECT
DS3
0
< 41mVpk
> 102mVpk
1
< 52mVpk
> 117mVpk
STS-1
0
< 51mVpk
> 114mVpk
1
< 58mVpk
> 133mVpk
FIGURE 8. LOSS OF SIGNAL DEFINITION FOR E3 AS PER ITU-T G.775
0 dB
-12 dB
-15dB
-35dB
Maximum Cable Loss for E3
LOS Signal Must be Declared
LOS Signal Must be Cleared
LOS Signal may be Cleared or Declared
相关PDF资料
PDF描述
XRT75R12IB-L IC LIU E3/DS3/STS-1 12CH 420TBGA
XRT75VL00DIV IC LIU E3/DS3/STS-1 1CH 52TQFP
XRT75VL00IV-F IC LIU E3/DS3/STS-1 1CH 52TQFP
XRT79L71IB-F IC LIU/FRAMER DS3/E3 1CH 208BGA
XRT81L27IV-F IC LIU EI 7CH 3.3V 128TQFP
相关代理商/技术参数
参数描述
XRT75R12ES 功能描述:时钟合成器/抖动清除器 12CH T3/E3/STS1LIUJA 3.3V W/REDUNDANCY RoHS:否 制造商:Skyworks Solutions, Inc. 输出端数量: 输出电平: 最大输出频率: 输入电平: 最大输入频率:6.1 GHz 电源电压-最大:3.3 V 电源电压-最小:2.7 V 封装 / 箱体:TSSOP-28 封装:Reel
XRT75R12IB 功能描述:外围驱动器与原件 - PCI 12CH E3/DS3/STS W/JITTER R3 TECH RoHS:否 制造商:PLX Technology 工作电源电压: 最大工作温度: 安装风格:SMD/SMT 封装 / 箱体:FCBGA-1156 封装:Tray
XRT75R12IB-F 功能描述:外围驱动器与原件 - PCI 12 Channel 3.3V-5V temp -45 to 85C RoHS:否 制造商:PLX Technology 工作电源电压: 最大工作温度: 安装风格:SMD/SMT 封装 / 箱体:FCBGA-1156 封装:Tray
XRT75R12IB-L 功能描述:LIN 收发器 Attenuator RoHS:否 制造商:NXP Semiconductors 工作电源电压: 电源电流: 最大工作温度: 封装 / 箱体:SO-8
XRT75VL00 制造商:EXAR 制造商全称:EXAR 功能描述:E3/DS3/STS-1 LINE INTERFACE UNIT WITH JITTER ATTENUATOR