Chapter 7
Functional Blocks
ICS1893AF, Rev. D 10/26/04
October, 2004
43
ICS1893AF Data Sheet - Release
Copyright 2004, Integrated Circuit Systems, Inc.
All rights reserved.
7.3.5
PCS Control Signal Generation
For the PCS sublayer, there are two control signals: a Carrier Sense signal (CRS) and a Collision Detect
signal (COL).
The CRS control signals is generated as follows:
1.
When a logic zero is detected in an idle bit stream, the Receive Functions examines the ensuing bits.
2.
When the Receive Functions find the first two non-contiguous zero bits, the Receive state machine
moves into the Carrier Detect state.
3.
As a result, the Boolean Receiving variable is set to TRUE.
4.
Consequently, the Carrier Sense state machine moves into the Carrier Sense ‘on’ state, which asserts
the CRS signal.
5.
If the PCS Functions:
a. Cannot confirm either the /I/J/ (IDLE, J) symbols or the /J/K/ symbols, the receive error signal
(RX_ER) is asserted, and the Receive state machine returns to the IDLE state. In IDLE, the
Boolean Receiving variable is set to FALSE, thereby causing the Carrier Sense state machine to
set the CRS signal to FALSE.
b. Can confirm the /I/J/K/ symbols, then the Receive state machine transitions to the ‘Receive’ state.
The COL control signal is generated by the transmit modules. For details, see Section 7.3.3.1, “PCS
7.3.6
4B/5B Encoding/Decoding
The 4B/5B encoding methodology maps each 4-bit nibble to a 5-bit symbol (also called a “code group”).
There are 32 five-bit symbols, which include the following:
Of the 32 five-bit symbols, 16 five-bit symbols are required to represent the 4-bit nibbles.
The remaining 16 five-bit symbols are available for control functions. The IEEE Standard defines 6
symbols for control, and the remaining 10 symbols of this grouping are invalid. The 6 control symbols
include the following:
– /H/, which represents a Halt, also used to signify a Transmit Error
– /I/, which represents an IDLE
– /J/, which represents the first symbol of the Start-of-Stream Delimiter (SSD)
– /K/, which represents the second symbol of the Start-of-Stream Delimiter (SSD)
– /T/, which represents the first symbol of the End-of-Stream Delimiter (ESD)
– /R/, which represents the second symbol of the End-of-Stream Delimiter (ESD)
If the ICS1893AF PCS receives:
– One of the 10 undefined symbols, it sets its QuickPoll Detailed Status Register’s Invalid Symbol bit
(bit 17.7) to logic one.
– A Halt symbol, it sets the Halt Symbol Detected bit in its QuickPoll Detailed Status Register (bit 17.6)
to logic one.
Note:
An STA can force the ICS1893AF to transmit symbols that are typically classified as invalid, by
both (1) setting the Extended Control Register’s Transmit Invalid Codes bit (bit 16.2) to logic one
and (2) asserting the associated TXER signal. For more information, see Section 8.11.7, “Invalid
相关PDF资料
PDF描述
IDT723641L20PF8 IC FIFO SYNC 1024X36 120-TQFP
IDT723631L20PQF IC FIFO SYNC 512X36 132-PQFP
ICS1893BFLFT PHYCEIVER LOW PWR 3.3V 48-SSOP
IDT723631L20PF IC FIFO SYNC 512X36 120-TQFP
VE-26F-IW-F2 CONVERTER MOD DC/DC 72V 100W
相关代理商/技术参数
参数描述
ICS1893AFT 功能描述:PHYCEIVER LOW PWR 3.3V 48-SSOP RoHS:否 类别:集成电路 (IC) >> 接口 - 驱动器,接收器,收发器 系列:PHYceiver™ 标准包装:1,000 系列:- 类型:收发器 驱动器/接收器数:2/2 规程:RS232 电源电压:3 V ~ 5.5 V 安装类型:表面贴装 封装/外壳:16-SOIC(0.295",7.50mm 宽) 供应商设备封装:16-SOIC 包装:带卷 (TR)
ICS1893AG 制造商:ICS 制造商全称:ICS 功能描述:3.3 V 10Base-T/100Base-TX Integrated PHYceiver-TM
ICS1893AGI 制造商:ICS 制造商全称:ICS 功能描述:3.3 V 10Base-T/100Base-TX Integrated PHYceiver-TM
ICS1893AGILF 制造商:ICS 制造商全称:ICS 功能描述:3.3 V 10Base-T/100Base-TX Integrated PHYceiver-TM
ICS1893AGLF 制造商:ICS 制造商全称:ICS 功能描述:3.3 V 10Base-T/100Base-TX Integrated PHYceiver-TM