参数资料
型号: DS2196LN+
厂商: Maxim Integrated Products
文件页数: 6/157页
文件大小: 0K
描述: IC FRAMER DUAL T1 LIU 100-LQFP
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 90
控制器类型: T1 调帧器
接口: 并行/串行
电源电压: 3.135 V ~ 3.465 V
电流 - 电源: 85mA
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 100-LQFP
供应商设备封装: 100-LQFP(14x14)
包装: 托盘
DS2196
103 of 157
18.1.2 STATUS REGISTER FOR THE HDLC
Four of the HDLC/BOC controller registers (HSR, RHIR, RBOC, and THIR) provide status information.
When a particular event has occurred (or is occurring), the appropriate bit in one of these four registers
will be set to a 1. Some of the bits in these four HDLC status registers are latched and some are real time
bits that are not latched. Section 18.1.4 contains register descriptions that list which bits are latched and
which are not. With the latched bits, when an event occurs and a bit is set to a 1, it will remain set until
the user reads that bit. The bit will be cleared when it is read and it will not be set again until the event
has occurred again. The real time bits report the current instantaneous conditions that are occurring and
the history of these bits is not latched.
Like the other status registers in the DS2196, the user will always proceed a read of any of the four
registers with a write. The byte written to the register will inform the DS2196 which of the latched bits
the user wishes to read and have cleared (the real time bits are not affected by writing to the status
register). The user will write a byte to one of these registers, with a 1 in the bit positions he or she wishes
to read and a 0 in the bit positions he or she does not wish to obtain the latest information on. When a 1
is written to a bit location, the read register will be updated with current value and it will be cleared.
When a 0 is written to a bit position, the read register will not be updated and the previous value will be
held. A write to the status and information registers will be immediately followed by a read of the same
register. The read result should be logically AND’ed with the mask byte that was just written and this
value should be written back into the same register to insure that bit does indeed clear. This second write
step is necessary because the alarms and events in the status registers occur asynchronously in respect to
their access via the parallel port. This write–read–write (for polled driven access) or write–read (for
interrupt driven access) scheme allows an external microcontroller or microprocessor to individually poll
certain bits without disturbing the other bits in the register. This operation is key in controlling the
DS2196 with higher–order software languages.
Like the SR1 and SR2 status registers, the HSR register has the unique ability to initiate a hardware
interrupt via the INT output pin. Each of the events in the HSR can be either masked or unmasked from
the interrupt pin via the HDLC Interrupt Mask Register (HIMR). Interrupts will force the INT pin low
when the event occurs. The INT pin will be allowed to return high (if no other interrupts are present)
when the user reads the event bit that caused the interrupt to occur.
18.1.3 Basic Operation Details
To allow the framer to properly source/receive data from/to the HDLC and BOC controller the legacy
FDL circuitry (which is described in Section 18.2) should be disabled and the following bits should be
programmed as shown:
TCR1.2 = 1 (source FDL data from the HDLC and BOC controller)
TBOC.6 = 1 (enable HDLC and BOC controller)
CCR2.5 = 0 (disable SLC–96 and D4 Fs–bit insertion)
CCR2.4 = 0 (disable legacy FDL zero stuffer)
CCR2.1 = 0 (disable SLC–96 reception)
CCR2.0 = 0 (disable legacy FDL zero stuffer)
IMR2.4 = 0 (disable legacy receive FDL buffer full interrupt)
IMR2.3 = 0 (disable legacy transmit FDL buffer empty interrupt)
IMR2.2 = 0 (disable legacy FDL match interrupt)
IMR2.1 = 0 (disable legacy FDL abort interrupt).
As a basic guideline for interpreting and sending both HDLC messages and BOC messages, the following
sequences can be applied:
相关PDF资料
PDF描述
DS21FF42 IC FRAMER T1 4X4 16CH 300-BGA
DS21FF44 IC FRAMER E1 4X4 16CH 300-BGA
DS21FT44N+ IC FRAMER 4X4 16CH 300-BGA
DS21Q352B IC TXRX QUAD T1/E1 3.3V 256-BGA
DS21Q41BT IC FRAMER T1 QUAD 128-TQFP
相关代理商/技术参数
参数描述
DS2196LN+ 功能描述:网络控制器与处理器 IC T1 Dual Framer LIU RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray
DS219T 功能描述:烙铁 DESOLDERING HEAD RoHS:否 制造商:Weller 产品:Soldering Stations 类型:Digital, Iron, Stand, Cleaner 瓦特:50 W 最大温度:+ 850 F 电缆类型:US Cord Included
DS21E352 功能描述:网络控制器与处理器 IC RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray
DS21E352N 功能描述:网络控制器与处理器 IC RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray
DS21E354 功能描述:网络控制器与处理器 IC RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray